My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
122 N Bewley St - Plan
PBA
>
Building
>
ProjectDox
>
B
>
Bewley St
>
122 N Bewley St Unit# 2
>
122 N Bewley St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 11:56:38 AM
Creation date
6/1/2025 11:56:30 AM
Metadata
Fields
Template:
Plan
Permit Number
20183560
101120258
Full Address
122 N Bewley St Unit# 2
Rectangle
ID:
1
Creator:
Import Agent
Created:
6/1/2025 11:56 AM
Modified:
5/30/2025 12:06 PM
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Wyssling Consulting <br />76 N. Meadowbrook Drive <br />Alpine, UT 84004 <br />(201) 874-3483 <br />swyssling@wysslingconsulting.com <br />V =95 Basic Wind Speed <br />Exposure C ASCE 7-16, Section 26.7 <br />Kz =0.85 Velocity Pressure Coefficient, ASCE 7-16, Figure 26.10-1 <br />Rey Residence <br />122 North Bewley Street Unit 2, <br />Santa Ana, CA 2.400 kW System <br />Kzt =1 Topographic Factor, ASCE 7-16, Section 26.8.2 <br />Kd =0.85 Directionality Factor, ASCE 7-16, Section 26.6 <br />Ke =1.000 Ground Elevation Factor, ASCE 7-16, Section 26.9 <br />qh =16.7 psf qh = 0.00256KzKztKdKeV2 (ASCE 7-16 Eq. 26.10-1) <br />Roof Angle =18 deg <br />Roof Type Hip <br />sanchor =72 in Horizontal spacing of roof anchors <br />Atrib =16.95 sf Panel Area tributary to each roof anchor <br />GCp External Pressure Coefficient, ASCE 7-16, Figure 30.3-2 <br />Roof Zone Zone 1 2e 2r Zone 3 <br />-1.30 -1.77 -2.36 -1.77 <br />ga =0.77 Pressure Equalization Factor, ASCE 7-16 Figure 29.4.-8 <br />gE =1.00 Edge Array Factor, ASCE 29.4.4 edges < 0.5*building height, and panel spacing < 4ft. <br />pnet = qhGCpgEga =Design Wind Pressure, ASCE 7-16, Equation 29.4-7 <br />Roof Zone 1 2e 2r Zone 3 <br />-17 psf -23 psf -30 psf -23 psf Min Pressure = -16 psf <br />Use 17 psf Use 23 psf Use 30 psf Use 23 psf ULTIMATE <br />x 0.6 =16 psf 16 psf 18 psf 16 psf ALLOWABLE <br />Connection to Existing Roof Framing <br />F.S. =1 Additional Factor of Safety applied to withdrawl force, if desired <br />Atrib =17.0 ft2 <br />DLpanel =3 psf <br />Roof Zone 1 2e 2r Zone 3 <br />Wuplift =17 psf 23 psf 30 psf 23 psf <br />Plag = F.S. x Atrib x (0.6D - 0.6W) =Withdrawl force for each roof anchor <br />Roof Zone 1 2e 2r Zone 3 <br />-143.8 lbs -205.7 lbs -282.1 lbs -205.7 lbs <br />Connection Capacity <br />db =5/16 in Lag Screw diameter <br />Dpen =2 1/2 in Lag Screw penetration into existing framing member <br />No. of Screws 1 Screws per Connection <br />Species of wood framing <br />CD =1.6 Load Duration Factor for Wind Loading, NDS Table 2.3.2 <br />Ct =0.7 Temperature Factor, NDS Table 10.3.4 <br />W =205 lb/in Withdrawl Capacity, NDS Equation 11.2-1 <br />W' = CD x Ct x W =229 lb/in Adjusted withdrawl value <br />Pallow = Dpen x W' =573 lbs <br />Roof Zone 1 2e 2r Zone 3 <br />DEMAND =144 lbs 206 lbs 282 lbs 206 lbs <br />CAPACITY =573 lbs 573 lbs 573 lbs 573 lbs <br />up to72in ok up to72in ok up to72in ok up to72in ok <br />This analysis calculates the <br />capacity of the lag screws <br />only. For capacity of the <br />complete mounting system, <br />please see manufacturer's <br />recommendations. <br />Spruce-Pine-Fir <br />Wind Uplift <br />Rooftop Solar Panels Parallel to Roof Surface <br />ASCE 7-16, Section 29.4.4 <br />Signed 6/12/2024 <br />122 N Bewley St <br />8/6/2024
The URL can be used to link to this page
Your browser does not support the video tag.