My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
122 N Bewley St - Plan
PBA
>
Building
>
ProjectDox
>
B
>
Bewley St
>
122 N Bewley St Unit# 2
>
122 N Bewley St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 11:56:38 AM
Creation date
6/1/2025 11:56:30 AM
Metadata
Fields
Template:
Plan
Permit Number
20183560
101120258
Full Address
122 N Bewley St Unit# 2
Rectangle
ID:
1
Creator:
Import Agent
Created:
6/1/2025 11:56 AM
Modified:
5/30/2025 12:06 PM
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
REV: A <br />AHJ: CA-CITY OF SANTA ANA <br />33.746021, -117.918404 <br />APN: 19818118 <br />DRAFTED BY: HILLARY <br />NAME: LAWRENCE REY ADDRESS: <br />122 NORTH BEWLEY STREET UNIT 2, <br />SANTA ANA, CA 92703 <br />UTILITY: SCE-SOUTHERN <br />CALIFORNIA EDISON <br />SCALE: AS NOTED <br />PRN NUMBER: SMT-98507 <br />PAPER SIZE: 17"X11"SHEET: CS-02DATE: 06/12/2024 <br />DRAWING INFORMATION <br />CUSTOMER INFORMATION CONTRACTOR INFORMATION <br />QC'ED BY: SUBHANI <br />PHONE NUMBER: (951) 536-7794 <br />GENERAL NOTES <br />INSTALLATION NOTES: <br />1. STRUCTURAL ROOF MEMBER LOCATIONS ARE ESTIMATED AND SHOULD BE LOCATED AND VERIFIED BY THE CONTRACTOR WHEN LAG BOLT PENETRATION OR MECHANICAL ATTACHMENT TO THE STRUCTURE IS REQUIRED. <br />2. ROOFTOP PENETRATIONS FOR SOLAR RACKING WILL BE COMPLETED AND SEALED WITH APPROVED SEALANT PER CODE BY A LICENSED CONTRACTOR. <br />3. LAGS MUST HAVE A MINIMUM 2.5" THREAD EMBEDMENT INTO THE STRUCTURAL MEMBER. <br />4. ALL PV RACKING ATTACHMENTS SHALL BE STACKED BY ROW BETWEEN THE ROOF FRAMING MEMBERS AS NECESSARY. <br />5. ROOF MOUNTED STANDARD RAIL REQUIRES ONE THERMAL EXPANSION GAP FOR EVERY RUN OF RAIL GREATER THAN 40'. <br />6. ALL CONDUCTORS AND CONDUITS ON THE ROOF SHALL BE MINIMUM 7/8" ABOVE THE ROOF SURFACE (INCLUDING CABLES UNDERNEATH MODULES AND RACKING). <br />7. THE PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL OR BUILDING ROOF VENTS. <br />8. ALL SOLAR PANEL ARRAY COMPONENTS SHALL BE INSTALLED PER THE MANUFACTURER'S APPROVED INSTALLATION SPECIFICATIONS. <br />9. THE EXISTING BUILDINGS STRUCTURE SHALL BE VERIFIED AS PROPERLY CONSTRUCTED AND MAINTAINED IN GOOD CONDITION. NO ALLOWANCE HAS BEEN MADE IN THESE DRAWINGS FOR ANY EXISTING DEFICIENCY IN DESIGN, MATERIAL, <br />CONSTRUCTION, OR LACK OF MAINTENANCE FOR THE EXISTING STRUCTURE OR PROPOSED EQUIPMENT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING EXISTING CONDITIONS, PROPER FIT, AND CLEARANCES IN THE FIELD. <br />10. WATERPROOFING AROUND THE ROOF PENETRATIONS IS THE RESPONSIBILITY OF CONTRACTOR/INSTALLER. <br />11.MISCELLANEOUS ITEMS NOT EXPLICITLY LISTED OR IDENTIFIED IN THESE DRAWINGS HAVE NOT BEEN DESIGNED. IT IS RECOMMENDED THAT MATERIAL OF SUITABLE SIZE STRENGTH TO BE OBTAINED FROM A REPUTABLE MANUFACTURER <br />FOR MISCELLANEOUS ITEMS. <br />12. IF ANY CONDITION THROUGHOUT THE ASSOCIATED REPORT OR PERMIT DRAWINGS IS NOT ALSO REPRESENTED ON-SITE, CONTRACTOR SHALL NOTIFY THE ENGINEER OF RECORD OF ANY DISCREPANCIES AND RECEIVE WRITTEN APPROVAL <br />FROM THE ENGINEER OF RECORD BEFORE PROCEEDING WITH INSTALLATION. <br />13.CONTRACTOR TO PROVIDE MINIMUM 1/4" GAP BETWEEN ALL SOLAR PANELS. <br />ROOF ACCESS PATHWAYS AND SETBACKS: <br />1205.2.1 SOLAR PHOTOVOLTAIC (PV) SYSTEMS FOR GROUP R-3 BUILDINGS <br />SOLAR PHOTOVOLTAIC (PV) SYSTEMS FOR GROUP R-3 BUILDINGS SHALL COMPLY WITH SECTIONS 1205.2.1.1 THROUGH 1205.2.3. <br />EXCEPTIONS: <br />1.THESE REQUIREMENTS SHALL NOT APPLY TO STRUCTURES DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH THE CALIFORNIA RESIDENTIAL CODE. <br />2. THESE REQUIREMENTS SHALL NOT APPLY TO ROOFS WITH SLOPES OF 2 UNITS VERTICAL IN 12 UNITS HORIZONTAL (16.7-PERCENT SLOPE) OR LESS. <br />1205.2.1.1 PATHWAYS TO RIDGE <br />NOT FEWER THAN TWO 36-INCH-WIDE (914 MM) PATHWAYS ON SEPARATE ROOF PLANES, FROM LOWEST ROOF EDGE TO RIDGE, SHALL BE PROVIDED ON ALL BUILDINGS. NOT FEWER THAN ONE PATHWAY SHALL BE PROVIDED ON THE STREET <br />OR DRIVEWAY SIDE OF THE ROOF. FOR EACH ROOF PLANE WITH A PHOTOVOLTAIC ARRAY, NOT FEWER THAN ONE 36-INCH-WIDE (914 MM) PATHWAY FROM LOWEST ROOF EDGE TO RIDGE SHALL BE PROVIDED ON THE SAME ROOF PLANE AS THE <br />PHOTOVOLTAIC ARRAY, ON AN ADJACENT ROOF PLANE OR STRADDLING THE SAME AND ADJACENT ROOF PLANES. <br />1205.2.1.2 SETBACKS AT RIDGE <br />FOR PHOTOVOLTAIC ARRAYS OCCUPYING 33 PERCENT OR LESS OF THE PLAN VIEW TOTAL ROOF AREA, A SETBACK OF NOT LESS THAN 18 INCHES (457 MM) WIDE IS REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE. FOR PHOTOVOLTAIC <br />ARRAYS OCCUPYING MORE THAN 33 PERCENT OF THE PLAN VIEW TOTAL ROOF AREA, A SETBACK OF NOT LESS THAN 36 INCHES (457 MM) WIDE IS REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE. <br />1205.2.1.3 ALTERNATIVE SETBACKS AT RIDGE <br />WHERE AN AUTOMATIC SPRINKLER SYSTEM IS INSTALLED WITHIN THE DWELLING IN ACCORDANCE WITH SECTION 903.3.1.3, SETBACKS AT THE RIDGE SHALL CONFORM TO ONE OF THE FOLLOWING: <br />1.FOR PHOTOVOLTAIC ARRAYS OCCUPYING 66 PERCENT OR LESS OF THE PLAN VIEW TOTAL ROOF AREA, A SETBACK OF NOT LESS THAN 18 INCHES (457 MM) WIDE IS REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE. <br />2.FOR PHOTOVOLTAIC ARRAYS OCCUPYING MORE THAN 66 PERCENT OF THE PLAN VIEW TOTAL ROOF AREA, A SETBACK OF NOT LESS THAN 36 INCHES (914 MM) WIDE IS REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE. <br />1205.2.2 EMERGENCY ESCAPE AND RESCUE OPENINGS: PANELS AND MODULES INSTALLED ON GROUP R-3 BUILDINGS SHALL NOT BE PLACED ON THE PORTION OF A ROOF THAT IS BELOW AN EMERGENCY ESCAPE AND RESCUE OPENING. A <br />PATHWAY OF NOT LESS THAN 36 INCHES (914 MM) WIDE SHALL BE PROVIDED TO THE EMERGENCY ESCAPE AND RESCUE OPENING. <br />SOLARMAX RENEWABLE ENERGY <br />PROVIDER INC. <br />3080 12TH ST, RIVERSIDE, CA 92507 <br />TEL: (951) 300-0788 <br />LICENSE NUMBER& <br />CLASS:972048/C-46 <br />David Bingwen Hsu <br /> David Bingwen Hsu, Lic. Holder <br />Signed 6/12/2024 <br />A <br />122 N Bewley St <br />8/6/2024
The URL can be used to link to this page
Your browser does not support the video tag.