Laserfiche WebLink
(N)JUNCTION <br />BOX DC CONDUCTORS <br />AC CONDUCTORS <br />MICROINVERTER <br />(1) BRANCH OF (6) MICROINVERTERS <br />(N)(6)TALESUN SOLAR BIPRO TP7G54M(H) (400W) MODULES WITH <br />(N)(6)ENPHASE IQ8PLUS-72-2-US (240V) [SI-1] <br />(1) <br />(1) <br />15A <br />20A <br />ENPHASE IQ COMBINER 5 <br />X-IQ-AM1-240-5 <br />120/240V NEMA 3R INSTALL <br /> 20A 2P PV BREAKER <br /> 15A 2P BREAKER FOR IQ <br />GATEWAY (ONLY FOR <br />SOLAR, NO LOADS TO BE <br />ADDED) <br />(N)ENPHASE IQ <br />COMBINER 5 <br />SQUARE D DU221RB <br />AC DISCONNECT NON <br />FUSED 30A, NEMA 3R, <br />120/240V, 2P <br />(N)30A AC <br />DISCONNECT <br />UTILITY <br />GRID <br />EXISTING 120/240V 1PH 60HZ <br />METER#: <br />SCE-SOUTHERN <br />CALIFORNIA EDISON <br />222013-565617 <br />M (E <br />) <br />1 <br />0 <br />0 <br />A <br /> <br />M <br />A <br />I <br />N <br />BR <br />E <br />A <br />K <br />E <br />R <br />(E)100A END FED MAIN <br />PANEL <br />(N)20A <br />2P PV BREAKER <br />PV BREAKER AT THE <br />OPPOSITE END OF <br />BUSBAR <br />(E) GROUND <br />ELECTRODE <br />G <br />N <br />1233 <br />IQ GATEWAY <br />14 AWG CU <br />WIRE <br />(PER CEC <br />240.4(D)) <br />REV: A <br />AHJ: CA-CITY OF SANTA ANA <br />33.746021, -117.918404 <br />APN: 19818118 <br />DRAFTED BY: HILLARY <br />NAME: LAWRENCE REY ADDRESS: <br />122 NORTH BEWLEY STREET UNIT 2, <br />SANTA ANA, CA 92703 <br />UTILITY: SCE-SOUTHERN <br />CALIFORNIA EDISON <br />SCALE: AS NOTED <br />PRN NUMBER: SMT-98507 <br />PAPER SIZE: 17"X11"SHEET: E-02DATE: 06/12/2024 <br />DRAWING INFORMATION <br />CUSTOMER INFORMATION CONTRACTOR INFORMATION <br />QC'ED BY: SUBHANI <br />PHONE NUMBER: (951) 536-7794 <br />SINGLE LINE DIAGRAM <br />DC SYSTEM SIZE- 2400W, AC SYSTEM SIZE - 1740W, CEC AC RATING - 2159W <br />CONDUCTOR AND CONDUIT SCHEDULE <br />TAG ID CONDUIT SIZE CONDUCTOR NEUTRAL GROUND <br />1 NONE (2) 12 AWG ENPHASE Q CABLE PER <br />BRANCH CIRCUIT NONE (1) 6 AWG BARE COPPER <br />2 3/4" EMT (2) 10 AWG THHN/THWN-2 NONE (1) 6 AWG THHN/THWN-2 <br />3 3/4" EMT (2) 10 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1) 6 AWG THHN/THWN-2 <br />NOTE: <br />1. EACH MICROINVERTER IS RAPID SHUTDOWN COMPLIANT. <br />2. ELECTRODES UNLESS BURIED OR ENCASED, ELECTRODE <br />CONNECTIONS MUST BE ACCESSIBLE. <br />SOLARMAX RENEWABLE ENERGY <br />PROVIDER INC. <br />3080 12TH ST, RIVERSIDE, CA 92507 <br />TEL: (951) 300-0788 <br />LICENSE NUMBER& <br />CLASS:972048/C-46 <br />David Bingwen Hsu <br /> David Bingwen Hsu, Lic. Holder <br />A <br />122 N Bewley St <br />8/6/2024