1. DETAILS OF CONSTRUCTION NOT SHOWN SHALL BE OF SAME NATURE AS <br />THOSE SHOWN FOR SIMILAR CONDITIONS. REFER TO THE TYPICAL DETAIL <br />SHEETS FOR TYPICAL DETAILS OF CONSTRUCTION. TYPICAL DETAILS APPLY TO <br />ALL CONSTRUCTION UNLESS SPECIFICALLY NOTED OR SHOWN OTHERWISE. <br />WHERE CONDITIONS REQUIRE MODIFICATIONS OF A TYPICAL DETAIL, THE <br />CONTRACTOR SHALL SUBMIT MODIFIED DETAIL FOR APPROVAL BY THE <br />ENGINEER OF RECORD PRIOR TO FABRICATION AND INSTALLATION. DETAILS <br />OF CONSTRUCTION NOT SHOWN SHALL BE OF SAME NATURE AS THOSE <br />SHOWN FOR SIMILAR CONSTRUCTION. <br /> <br />2. CONTRACTOR SHALL CONSIDER THE PROJECT SPECIFICATIONS A PART OF THE <br />CONTRACT DOCUMENTS. WHERE INFORMATION IS CONFLICTING, SPECIFIC <br />DETAILS SHALL GOVERN OVER TYPICAL DETAILS WHICH SHALL GOVERN OVER <br />THESE NOTES WHICH SHALL GOVERN OVER SPECIFICATIONS. <br />3. ALL DIMENSIONS ON STRUCTURAL DRAWINGS SHALL BE CHECKED AGAINST <br />ARCHITECTURAL DIMENSIONS. DO NOT SCALE DRAWINGS. IF DIMENSIONS ARE <br />OMITTED OR NOT CLEAR, CONTACT THE ARCHITECT (ARCH) OR STRUCTURAL <br />ENGINEER OF RECORD (SEOR). ALL DIMENSIONS RELATED TO EXISTING <br />CONDITIONS SHALL BE FIELD VERIFIED BY THE CONTRACTOR. DIMENSIONS <br />ARE TO THE FACE OF STUDS, AND TO CENTERLINE OF COLUMNS UNO. <br />4. IT IS THE CONTRACTOR'S RESPONSIBILITY TO IMMEDIATELY NOTIFY THE <br />STRUCTURAL ENGINEER OF ANY CONFLICTS BETWEEN THE STRUCTURAL <br />DRAWINGS AND OTHER DRAWINGS; OR EXISTING CONDITIONS NOT SHOWN OR <br />DIFFERENT FROM THOSE SHOWN ON DRAWINGS PRIOR TO COMMENCEMENT <br />OF WORK. THE CONTRACTOR IS NOT TO ORDER MATERIAL OR CONSTRUCT <br />ANY PORTION OF THE BUILDING THAT IS IN CONFLICT UNTIL THE CONFLICT IS <br />RESOLVED WITH THE AFFECTED PARTIES. <br />5. THE STRUCTURAL DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED <br />STRUCTURE. UNLESS OTHERWISE SHOWN THEY DO NOT INDICATE METHOD OF <br />CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL MEASURES <br />NECESSARY TO PROTECT THE CONSTRUCTION AND ALL ADJACENT <br />PROPERTIES DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE BUT <br />ARE NOT LIMITED TO BRACING, SHORING OF LOADS DUE TO CONSTRUCTION <br />EQUIPMENT, ETC. OBSERVATION VISITS TO THE SITE BY THE ARCHITECT OR <br />SEOR SHALL NOT INCLUDE OBSERVATION OF THE ABOVE ITEMS. <br />6. SUBSTITUTION REQUESTS FOR MATERIALS SPECIFIED ON THE STRUCTURAL <br />DRAWINGS MAY BE CONSIDERED WITH MATERIALS HAVING EQUIVALENT OR <br />GREATER CAPACITY AND PERFORMANCE. CURRENT EVALUATION REPORTS <br />AND PRODUCT INFORMATION SHALL BE PROVIDED TO THE STRUCTURAL <br />ENGINEER DEMONSTRATING THE REQUIRED CAPACITY AND PERFORMANCE OF <br />THE MATERIAL TO BE SUBSTITUTED. WRITTEN APPROVAL FROM THE <br />STRUCTURAL ENGINEER SHALL BE OBTAINED PRIOR TO THE SUBSTITUTION OF <br />ANY MATERIAL SPECIFIED ON THE STRUCTURAL DOCUMENTS. <br />7. IT IS THE CONTRACTOR'S RESPONSIBILITY TO COMPLY WITH THE PERTINENT <br />SECTIONS OF THE "CONSTRUCTION SAFETY ORDERS" ISSUED BY THE STATE <br />OF CALIFORNIA, LATEST EDITION, AND ALL OSHA REQUIREMENTS AS THEY <br />APPLY TO THIS PROJECT. THE ARCHITECT, SEOR, AND THE OWNER DO NOT <br />ACCEPT ANY RESPONSIBILITY FOR THE CONTRACTOR'S FAILURE TO COMPLY <br />WITH THESE REQUIREMENTS. <br /> <br />8. ALL WORK IS NEW (N) UNLESS INDICATED AS EXISTING (E). <br />9. CONSTRUCTION MATERIALS SHALL BE DISTRIBUTED WHEN PLACED ON THE <br />STRUCTURE SUCH THAT LOADS DO NOT EXCEED DESIGN LIVE LOADS OR <br />RESULT IN AN UNBALANCED CONDITION. <br />GENERAL NOTES: <br />1. CODES: <br />ALL WORK SHALL BE IN CONFORMANCE WITH THE CALIFORNIA <br />BUILDING CODE (CBC) 2022 EDITION, INCLUDING ALL AMENDMENTS. <br /> ALL STANDARDS USED SHALL BE THE LATEST VERSION APPROVED <br />BY THE CODE ENFORCEMENT AGENCY ON THE DATE OF THE PERMIT <br />ISSUANCE UNLESS SPECIFICALLY NOTED OTHERWISE. <br />2. DESIGN LIVE LOAD <br /> <br />3. WIND DESIGN INFORMATION <br />4. SEISMIC DESIGN INFORMATION <br />STRUCTURAL DESIGN CRITERIA: <br />RISK CATEGORY = II Kz = 1.0 Kd =0.85 Kzt = 1.0 <br />BASIC WIND SPEED Vfm = 95 MPH (3 SEC GUST) EXPOSURE = C <br />INTERNAL PRESSURE COEFF. = +/- 0.18 <br />I = 1.0 RISK CATEGORY = II SITE CLASS = D <br />SS = 1.327 S1 = 0.473 SDS = 1.062 SD1 = 0.851 <br />SEISMIC DESIGN CATEGORY = D <br />ANALYSIS PROCEDURE = EQUIV. LATERAL FORCE PROCEDURE <br />LOAD <br />ROOF 20 PSF <br />SLRS : ORDINARY STEEL CANTILEVERED COLUMN <br />R = 1.25 Cd = 1.25 Ω = 1.25 <br />1. FIELD VERIFY ALL CONDITIONS & DIMENSIONS PRIOR TO SHOP DRAWING <br />PRODUCTION AND FABRICATION OF STRUCTURAL ELEMENTS. <br />2. WHERE ALL OTHER EXISTING CONDITIONS VARY SIGNIFICANTLY FROM THOSE <br />SHOWN ON THESE DRAWINGS, THE STRUCTURAL ENGINEER SHALL BE <br />NOTIFIED PRIOR TO CONTINUED CONSTRUCTION RELATED TO SUBJECT <br />CONDITIONS. <br />3. SHORE ALL EXISTING CONSTRUCTION AS REQUIRED. <br />4. ALL EXISTING (E) CONNECTIONS AT ELEMENTS TO BE REPLACED SHALL BE <br />REPLACED OR RE-ATTACHED TO MATCH EXISTING CONDITIONS. <br />5. VERIFY LOCATION OF EXISTING (E) REBAR BEFORE FABRICATION USING NON- <br />DESTRUCTIVE TESTING. <br />6. ALL EXISTING (E) WOOD ELEMENTS TO REMAIN SHALL BE FIELD INSPECTED <br />DURING CONSTRUCTION AND TREATED FOR DRYROT REMOVAL / CONTROL. <br />WHERE EXISTING GLB'S TO REMAIN ARE FOUND TO HAVE EXTENSIVE DRYROT <br />DEEPER THAN THE TOP TWO LAMINATIONS (3"), THE STRUCTURAL ENGINEER <br />SHALL BE NOTIFIED PRIOR TO CONTINUED CONSTRUCTION RELATED TO <br />SUBJECT GLB'S. <br />7. CORE DRILLS REQUIRED SHALL NOT CUT ANY REINFORCING. THE <br />CONTRACTOR IS TO COORDINATE WORK OF ALL TRADES TO ENSURE <br />COMPLIANCE. ALL CORE DRILLS ARE TO BE PRESENTED TO THE IOR FOR <br />VERIFICATION. THE INSPECTOR IS TO DOCUMENT CORES EXAMINED <br />INDICATING AN ABSENCE OF REINFORCING. <br />EXISTING CONDITIONS NOTES: <br />1. THE ARCHITECT AND ENGINEERS ARE NOT RESPONSIBLE FOR THE LOCATIONS <br />OF EXISTING UNDERGROUND UTILITIES WHETHER OR NOT SHOWN ON THE <br />DRAWINGS. THE LOCATION OF ANY EXISTING UNDERGROUND UTILITIES <br />SHOWN ON THE DRAWINGS ARE APPROXIMATE. THE CONTRACTOR SHALL <br />IMMEDIATELY NOTIFY THE OWNER SHOULD ANY SUCH UNIDENTIFIED <br />CONDITIONS BE DISCOVERED. <br />2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGES WHICH MAY <br />RESULT FROM HIS FAILURE TO EXACTLY LOCATE AND PRESERVE ALL EXISTING <br />UNDERGROUND UTILITIES. <br />EXISTING UNDERGROUND UTILITY NOTES: <br />FOUNDATION NOTES (NO SOILS REPORT): <br />1. NO SOILS REPORT AVAILABLE; THEREFORE, MINIMUM VALUES USED <br />PER 2022 CBC. <br />2. ALLOWABLE VERTICAL BEARING PRESSURE = 1500 PSF <br />ALLOWABLE LATERAL BEARING PRESSURE = 100 PSF PER FT OF DEPTH <br />3. THE CONTRACTOR SHALL CONFORM TO ALL RECOMMENDATIONS AND <br />CONDITIONS INDICATED IN THE 2022 CBC. A GEOTECHNICAL ENGINEER SHALL <br />OBSERVE ALL FOOTING EXCAVATIONS PRIOR TO PLACING CONCRETE. <br />4. SUBSURFACE SOIL PREPARATION: <br />A. ALL EXISTING UNDOCUMENTED FILL AND TOPSOILS SHALL BE REMOVED <br />AND RECOMPACTED. BACKFILL SHALL BE FREE OF ORGANIC MATERIAL, <br />CONSTRUCTION DEBRIS, COBBLE AND BOLDERS. <br />B. ALL EXPANSIVE SOIL SHALL BE REMOVED PER CBC 1808A.6.3 <br />C. GEOTECHNICAL ENGINEER SHALL BE RETAINED DURING THE <br />OVEREXCAVATION PROCESS. THE ACTUAL DEPTH OF REMOVAL WILL BE <br />DETERMINED DURING GRADING OPERATIONS TO CONFIRM COMPETENT <br />NATIVE SOIL MATERIALS ARE ENCOUNTERED. <br />D. OFFSITE FILL MATERIAL SHALL BE APPROVED BY A GEOTECHNICAL <br />ENGINEER PRIOR TO PLACEMENT. <br />5. COMPACTED ENGINEERED FILL MATERIAL SHALL BE PLACED IN LOOSE LIFTS <br />OF 6 TO 8 INCHES AND SHALL HAVE AN IN-PLACE DRY DENSITY IS NOT LESS <br />THAN 90 PERCENT OF THE MAXIMUM DRY DENSITY AT OPTIMUM MOISTURE <br />CONTENT DETERMINED IN ACCORDANCE WITH ASTM D1557. THE COMPACTION <br />SHALL BE VERIFIED BY SPECIAL INSPECTION. <br />6. SPREAD FOOTINGS ARE CENTERED UNDER WALLS AND COLUMNS, UNO. <br />7. FOOTING ELEVATIONS ARE NOTED ON THE PLANS AND DETAILS AND SHALL BE <br />USED FOR BIDDING. IN ANY CASE, FOOTINGS SHALL BEAR ON FIRM <br />UNDISTURBED SOIL OR ENGINEERED FILL, IN ACCORDANCE WITH THE 2022 <br />CBC AND DETAILS SHOWN. <br />8. CONTRACTOR SHALL PROTECT ALL UTILITY LINES, ETC. ENCOUNTERED <br />DURING EXCAVATION AND BACKFILLING. <br />9. ALL TRENCHES SHALL COMPLY WITH APPLICABLE OSHA REQUIREMENTS. <br />10. <br />1. CONCRETE SHALL BE MIXED, PLACED AND CURED IN ACCORDANCE WITH ACI <br />318, 2019 EDITION, AND PROJECT SPECIFICATIONS. <br />2. CONCRETE SHALL NOT BE DROPPED THROUGH REINFORCING STEEL (AS IN <br />WALLS) SO AS TO CAUSE SEGREGATION OF AGGREGATES. IN SUCH CASES, <br />HOPPERS AND VERTICAL CHUTES OR TRUNKS SHALL BE USED. CHUTES OR <br />TRUNKS SHALL BE OF VARIABLE LENGTHS SO THAT FREE UNCONFINED FALL <br />OF CONCRETE SHALL NOT EXCEED SIX FEET. A SUFFICIENT NUMBER OF <br />CHUTES OR TRUNKS SHALL BE USED TO ENSURE THE CONCRETE IS KEPT <br />LEVEL AT ALL TIMES. <br />3. CONSTRUCTION JOINTS SHALL BE CLEANED AND ROUGHENED BY REMOVING <br />THE ENTIRE SURFACE TO EXPOSE CLEAN AGGREGATE SOLIDLY EMBEDDED IN <br />THE MORTAR MATRIX. SLUSH WITH A COAT OF NEAT CEMENT BEFORE <br />PLACING CONCRETE. SEE PLANS AND DETAILS FOR LOCATION AND TYPE OF <br />CONSTRUCTION JOINT. LOCATIONS OF ADDITIONAL CONSTRUCTION JOINTS <br />NOT SHOWN ON THESE PLANS SHALL BE SUBMITTED FOR APPROVAL BY THE <br />EOR PRIOR TO PLACING ANY CONCRETE. <br />4. STRUCTURAL CONCRETE SHALL MEET THE FOLLOWING DESIGN CRITERIA: <br /> <br />a. MAXIMUM DRY WEIGHT OF LIGHTWEIGHT CONCRETE SHALL BE <br /> 110 PCF . <br />b. SLUMP MEASURED PRIOR TO SUPERPLASTICIZER, WHERE OCCURS. <br />5. CONCRETE MIX DESIGN AND TESTING SHALL MEET THE REQUIREMENTS OF <br />THE BUILDING CODE, AND SPECIFICATIONS. ALL CONCRETE MIXES SHALL BE <br />DESIGNED BY A RECOGNIZED TESTING LAB STAMPED AND SEALED BY A <br />LICENSED CALIFORNIA CIVIL ENGINEER AND SUBMITTED TO THE SEOR FOR <br />REVIEW PRIOR TO CONCRETE PLACEMENT. STRUCTURAL CONCRETE MIXES <br />SHALL CONSIST OF 5 SACK MINIMUM U.N.O. <br />6. AGGREGATES IN NORMAL WEIGHT CONCRETE SHALL CONFORM TO ASTM C-33 <br />(HARDROCK). AGGREGATES IN LIGHT WEIGHT CONCRETE SHALL CONFORM <br />TO ASTM C-330. <br />7. COMPRESSIVE STRENGTH TEST REPORTS SHALL BE SUBMITTED TO THE <br />BUILDING DEPARTMENT AND THE SEOR. <br />8. PORTLAND CEMENT SHALL BE AS NOTED ABOVE FOR ALL CONCRETE <br />CONFORMING TO ASTM C150, LOW ALKALI. MILL TESTS WITH CERTIFICATES <br />OF COMPLIANCE SHALL BE SUBMITTED. <br />9. CONCRETE MIXING OPERATIONS, ETC. SHALL CONFORM TO ASTM C94. <br />10. LEAN CONCRETE, WHERE SPECIFICALLY INDICATED, SHALL CONTAIN 2 SACKS <br />OF CEMENT PER CUBIC YARD OF CONCRETE. <br />11. DRYPACK OR NONSHRINK GROUT SHALL HAVE A MINIMUM 28 DAY <br />COMPRESSIVE STRENGTH OF 2 TIMES THE SUPPORTING CONCRETE <br />STRENGTH, AND SHALL BE OF FIVE STAR GROUT, SIKA GROUT 212, OR <br />APPROVED EQUAL WITH VALID CODE REPORT (LARR,ICC,ESR,IAPMO ER). <br />FOR THICK GROUT LAYERS FOLLOW MANUFACTURER'S GUIDELINES TO <br />ATTAIN THE REQUIRED STRENGTH, WHICH MAY INCLUDE THE ADDITION OF <br />PEA GRAVEL. <br />12. DO NOT USE ANY CONCRETE OR GROUT CONTAINING CHLORIDES. WATER <br />USED IN MIX SHALL BE CLEAN AND POTABLE. <br />13. FOR INTERIOR SLABS-ON-GRADE AND ALL OTHER SLABS RECEIVING ADHERED <br />FLOORING FINISHES (I.E., GLUED, ETC.), THE MAXIMUM W/C RATIO SHALL NOT <br />EXCEED 0.45. CURING COMPOUNDS USED ON CONCRETE THAT IS TO RECIEVE <br />FINISHES SHALL BE COMPATIBLE WITH TILE AND ADHESIVES OR GROUTS IN <br />ACCORDANCE WITH MANUFACTURER'S DATA AND BE APPROVED BEFORE <br />USE. <br />14. MAINTAIN CONCRETE ABOVE 50 DEGREES FAHRENHEIT AND IN A MOIST <br />CONDITION FOR A MINIMUM OF 7 DAYS AFTER PLACEMENT UNLESS <br />OTHERWISE ACCEPTED BY SEOR. <br />15. SEE ARCHITECTURAL DRAWINGS FOR WALL OPENINGS, W ALL OFFSETS, <br />CHAMFERS, KERFS, DRIPS AND FOR EXTENT OF DEPRESSIONS, RAMPS, ETC. <br />PROVIDE SLEEVES FOR ALL PIPES THROUGH CONCRETE WALLS AND <br />FOOTINGS WHERE SHOWN ON THESE DRAWINGS. CORING IS NOT PERMITTED <br />WITHOUT PRIOR APPROVAL BY THE SEOR. <br />16. SEE ARCHITECT'S PLANS FOR LOCATIONS OF SLAB SLOPES, DEPRESSIONS, <br />CURBS, DRAINS, NON-STRUCTURAL PARTITIONS AND OTHER EMBEDDED <br />ITEMS NOT SHOWN ON THE STRUCTURAL PLANS. <br />17. EXPOSED CORNERS OF SLABS, BEAMS, WALLS, COLUMNS, ETC. SHALL BE <br />FORMED WITH 3/4" CHAMFER, U.N.O. <br />18. CONSTRUCTION JOINTS (CJ) AND SAWCUT (SC) JOINTS IN SLABS SHALL <br />OCCUR WHERE LOCATED ON PLANS AND DETAILS. CJ'S SHALL HAVE FORMED <br />POUR STOPS. CONSTRUCTION JOINTS IN WALLS AND FOOTINGS NEED NOT <br />OCCUR AT THE SAME LOCATION, U.N.O. <br />STRUCTURAL CONCRETE NOTES: <br />LOCATION <br />MIN 28-DAY <br />COMP <br />STRENGTH <br />FOUNDATIONS <br />STEM WALLS, PILASTER 4000 PSI NWC 1 1/2" 0.45 4" II / V <br />CONC <br />TYPEa <br />MAX <br />AGGR. <br />SIZE <br />MAX <br />W/C <br />RATIO <br />MAX <br />SLUMPb <br />CEMENT <br />TYPE <br />4000 PSI NWC 1" 0.45 4" II / V <br />4000 PSI NWC 1" 0.50 6" II / V <br />SLAB ON GRADE <br />ALL OTHER STRUCTURAL <br />CONCRETE NO NOTED.. <br />1. DESIGN, FABRICATION AND ERECTION OF COLD-FORMED STEEL <br />FRAMING SHALL CONFORM TO THE SPECIFICATIONS AND STANDARD OF <br />THE AMERICAN IRON AND STEEL INSTITUTE (AISI), AS CONTAINED IN THE <br />"SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL <br />STRUCTURAL MEMBERS", LATEST EDITION, INCLUDING ALL APPLICABLE <br />AMENDMENTS. <br />2. ALL COLD-FORMED STEEL FRAMING SHALL BE ERECTED PLUMB AND <br />TRUE TO LINE. TEMPORARY BRACING SHALL BE INSTALLED AND LEFT IN <br />PLACE UNTIL OTHER MEANS IS PROVIDED TO ADEQUATELY BRACE THE <br />STRUCTURE. <br />3. COLD-FORMED STEEL GRADES: <br />A. 18 GA (43 MILS) OR THINNER .........ASTM A1003 GRADE 33 (FY = 33 KSI) <br />B. 16 GA (54 MILS) AND THICKER .......ASTM A1003 GRADE 50 (FY = 50 KSI) <br />4. ALL COLD-FORMED STEEL FRAMING SHALL BE BRACED AS REQUIRED BY <br />SECTION D3 OF THE AISI SPECIFICATION. <br />5. SUBMIT COLD-FORMED STEEL FRAMING SHOP DRAWINGS AND <br />SPECIFICATIONS TO THE SEOR FOR REVIEW PRIOR TO FABRICATION. <br />6. COLD-FORMED STEEL STUDS AND TRACKS ARE TO BE ATTACHED WITH <br />SHEET METAL SCREWS (SMS) WITH SIZES CALLED OUT ON THE DETAILS. <br />PENETRATION OF SCREWS THROUGH JOINED MATERIAL SHOULD NOT <br />BE LESS THAN 3 EXPOSED THREADS. SCREWS ARE TO BE INSTALLED <br />AND TIGHTENED IN ACCORDANCE WITH SCREW MANUFACTURER'S <br />RECOMMENDATIONS. <br />7. ALL HOLES FOR BOLTS SHOULD BE SHALL BE STANDARD HOLES. <br />8. GALVANIZED COATING SHALL COMPLY WITH ASTM A924. <br />9. COLD-FORMED STEEL FRAMING SHALL BE PER STEEL STUD <br />MANUFACTURER'S ASSOCIATION (SSMA), ICC ER-3064P. <br />COLD-FORMED STEEL FRAMING NOTES: <br />TYPICAL ABBREVIATIONS <br />A.B.ANCHOR BOLT <br />INT INTERIOR <br />ABV ABOVE <br />ADDT'L ADDITIONAL <br />KLF KIPS PER LINEAR FOOT <br />ADJ ADJACENT <br />KSL KIPS PER SQUARE FOOT <br />A.F.F.ABOVE FINISH FLOOR <br />KSI KIPS PER SQUARE INCH <br />ALT ALTERNATE <br />L ANGLE <br />ARCH ARCHITECT(URAL)LFRS LATERAL FORCE <br />BLDG BUILDING <br />RESISTING SYSTEM <br />BLK'G BLOCKING <br />LLH LONG LEG HORIZONTAL <br />BLW BELOW <br />LLV LONG LEG VERTICAL <br />BM BEAM LP LOW POINT <br />BN BOUNDARY NAILING LWC LIGHTWEIGHT CONCRETE <br />B.O.BOTTOM OF MAX MAXIMUM <br />BOT BOTTOM M.B.MACHINE BOLT <br />BRG BEARING MECH MECHANICAL <br />B.S.BOTH SIDES MFR MANUFACTURER <br />BTWN BETWEEN MIN MINIMUM <br />C CAMBER OR MTL METAL <br />C.I.P.CAST IN PLACE <br />(N)NEW <br />CJ CONTROL/ NS NEAR SIDE OR NON-SHRINK <br />CONSTRUCTION JOINT NTS NOT TO SCALE <br />CL CENTERLINE NWC NORMAL WEIGHT CONCRETE <br />CLR CLEAR <br />O.C.ON CENTERCMUCONCRETE MASONRY UNIT <br />O.F.OUTSIDE FACECOLCOLUMN <br />OH OPPOSITE HANDCONCCONCRETE <br />OPM <br />OSHPD PRE APPROVAL OFCONN CONNECTION <br />PDF POWDER DRIVEN FASTENER <br />CONT CONTINUOUS <br />PJ PANEL JOIST <br />CP COMPLETE PENETRATION <br />PL PLATE <br />CSK COUNTERSINK <br />PLC(S) PLACE(S) <br />CTR(D) CENTER(ED) <br />PLF POUND PER LINEAR FOOT <br />DB BAR OR BOLT DIAMETER <br />PLYWD PLYWOOD <br />DBL DOUBLE <br />PREFAB PREFABRICATED <br />DC DEMAND CRITICAL <br />PSF POUND PER SQUARE FOOT <br />DEMO DEMOLITION <br />PSI POUND PER SQUARE INCH <br />DET DETAIL <br />PT PRESSURE TREATED OR <br />DIA DIAMETER <br />POST TENSION <br />DIAG DIAGONAL <br />QTY QUNATITY <br />DIM DIMENSION <br />RAD, R RADIUS <br />DO DITTO <br />REF REFERENCE <br />DWG DRAWING <br />REINF REINFORCING <br />(E) EXISITNG <br />REQ'D REQUIRED <br />EA EACH <br />SB SILL BOLT <br />E.F. EACH FACE <br />SC SAW CUT OR SLIP CRITICAL <br />EJ EXPANSION JOIST <br />SCHED SCHEDULE <br />EMBED EMBEDMENT <br />SEOR STRUCTURAL ENGINEER <br />ELEC ELECTRICAL <br />ON RECORD <br />ELEV ELEVATION <br />SHT'G SHEATHING <br />EN EDGE NAILING <br />SIM SIMILAR <br />E.O.EDGE OF <br />SLRS SEISMIC LOAD <br />EOR ENGINEER OF RECORD <br />RESISTING SYSTEM <br />EQ EQUAL <br />SMS SHEET METAL SCREW <br />EQUIP EQUIPMENT <br />SN SILL NAIL <br />E.S.EACH SIDE/ EDGE SCREW <br />S.O.G.SLAB ON GRADE <br />E.W.EACH WAY <br />SQ SQUARE <br />EXP EXPANSION <br />SS STAINLESS STEEL <br />EXT EXTERIOR <br />STD STANDARD <br />FIN FINISH <br />STAGG.STAGGERED <br />FLR FLOOR <br />SITFF STIFFENER <br />FN FIELD NAILING <br />STL STEEL <br />FND FOUNDATION <br />STRUCT STRUCTURAL <br />F.O. FACE OF <br />T&B TOP AND BOTTOM <br />FS FAR SIDE OR FIELD SCREW <br />THK THICK <br />FRM'G FRAMING <br />T.O. TOP OF <br />FT FOOT OR FEET <br />T.O.M.TOP OF MASONRY <br />FTG FOOTING <br />T.O.S.TOP OF STEEL <br />G GIRDER <br />TYP TYPICAL <br />GA GAUGE <br />U.N.O. UNLESS NOTED OTHERWISE <br />GALV GALVANIZED <br />VERT VERTICAL <br />H.A.B. HEADED ANCHOR BOLT <br />W/WITH <br />HD HOLDOWN <br />W/O WITHOUT <br />HDR HEADER <br />WF WIDE FLANGE/WALL FOOTING <br />HGR HANGER <br />WLD WELDED <br />HK HOOK <br />WO WHERE OCCURS <br />HORIZ HORIZONTAL <br />WP WORK POINT <br />HP HIGH POINT <br />WT WEIGHT <br />HS HIGH STRENGTH <br />WWF WELDED WIRE FABRIC <br />HSS HOLLOW STRUCTURAL <br />SECTION <br />REFERENCE ELEVATION OR <br />HT HEIGHT <br />WORK POINT <br />IN INCH <br />PENE PENETRATION <br />OPN'G OPENING <br />MANUFACTURER’S <br />CERTIFICATION <br />A.T.R. ALL THREADED ROD <br />LBS POUND <br />WWM WELDED WIRE MESH <br />GB GRADE BEAM <br />LONG. LONGITUDINAL <br />SF SPREAD FOOTING <br />TRANS. TRANSVERSE <br />LLBB LONG LEG BACK TO BACK <br />JST JOIST <br />PERF PERFORATED <br />NOM. NOMINAL <br />R.O. ROUGH OPENING <br />OD OUTSIDE DIAMETER <br />RJ ROOF JOIST <br />FJ FLOOR JOIST <br />C-CHANNEL <br />DIST DISTANCE <br />W.S.WELDED STUD <br />FN HT FINISH HEIGHT <br />⌀DIAMETER <br />FINISH SURFACE <br />1. REINFORCING GRADES FOR CONCRETE OR MASONRY: <br /> <br />2. MAINTAIN MINIMUM CONCRETE COVER FROM FACE OF CONCRETE TO EDGE OF <br />ALL REINFORCEMENT AS FOLLOWS (U.N.O.): <br />(SEE PLAN/ SECTION FOR CONCRETE W/ FIRE RATING.) <br /> <br />PROVIDE THE LARGEST COVER REQUIRED FOR ALL APPLICABLE CONDITIONS. <br />WHERE #3 STIRRUPS OR TIES ARE USED, ENSURE THAT THE COVER FOR <br />LONGITUDINAL BARS IS ADEQUATE. <br />3. REINFORCEMENT SHALL BE PLACED IN ACCORDANCE WITH THE CONCRETE <br />REINFORCING STEEL INSTITUTE (CRSI) "MANUAL OF STANDARD PRACTICE". <br />EACH REINFORCING BAR SHALL BE WIRED TO A CROSS BAR AT A MAXIMUM <br />SPACING OF 24" O.C. PROVIDE ALL ACCESSORIES NECESSARY TO SUPPORT <br />REINFORCING IN POSITIONS SHOWN ON THE PLANS. <br />4. SPLICES IN CONTINUOUS REINFORCEMENT AS USED IN W ALLS, FOOTINGS, <br />SLABS, ETC., SHALL HAVE A CLASS "B" LAP (1' - 6" MIN) AND THE SPLICES IN <br />ADJACENT BARS SHALL BE NOT LESS THAN 5' - 0" APART. VERTICAL WALL BARS <br />SHALL BE SPLICED AT OR NEAR FLOOR LINES. BARS MAY BE WIRED <br />TOGETHER AT SPLICES OR LAPS EXCEPT FOR TOP REINFORCING OF BEAMS <br />AND SLABS OR WHERE SPECIFICALLY DETAILED TO BE SEPARATED. WELDED <br />WIRE FABRIC SHALL BE LAPPED 12" MINIMUM. <br />5. ALL DOWELS, ANCHOR BOLTS AND OTHER HARDWARE TO BE SET IN <br />CONCRETE SHALL BE TIED IN PLACE PRIOR TO PLACEMENT OF CONCRETE. NO <br />WET SETTING, STABBING, RODDING OR OTHER MOVEMENT OF EMBEDDED <br />ITEMS SHALL BE PERFORMED DURING PLACEMENT OF CONCRETE. <br />6. BEND REINFORCING BARS COLD. <br />7. STEEL SHALL BE KEPT CLEAN AND FREE OF RUST. <br />8. DOWELS BETWEEN FOOTING AND WALLS OR COLUMNS SHALL BE THE SAME <br />GRADE, SIZE AND SPACING AS THE MAIN REINFORCING U.N.O. <br /> <br />9. ALL BARS SHALL BE MARKED SO THEIR IDENTIFICATION CAN BE MADE WHEN <br />THE FINAL IN PLACE INSPECTION IS MADE. <br />10. CHAIRS OR SPACERS FOR REINFORCING SHALL BE NON-FERROUS OR PLASTIC <br />COATED WHEN RESTING ON EXPOSED SURFACES. <br />REINFORCING STEEL NOTES: <br />ALL BARS EXCEPT THOSE TO BE WELDED <br />TIES AND STIRRUPS <br />WELDED WIRE FABRIC <br />ALL BARS TO BE WELDED <br />ALL BARS IN THE CONCRETE SHEARWALL <br />INDICATED ON WALL ELEVATION INCLUDING <br />SUPPORTING WALL FOOTING LONGITUDINAL <br />BARS (WF), AND ALL GRADE BEAMS (GB) <br />ASTM A615, GRADE 60 <br />ASTM A615, GRADE 60 <br />ASTM A1064 <br />ASTM A706, GRADE 60 <br />A706, GRADE 60 <br />CONDITION <br />CONCRETE PLACED AGAINST EARTH <br />CONCRETE PLACED IN FORMS AND <br />EXPOSED TO WEATHER OR EARTH <br />-#6 BARS AND LARGER <br />-#5 BARS AND SMALLER <br />INTERIOR COLUMNS AND BEAMS <br />INTERIOR WALL FACES AND RAISED SLABS <br />STRUCTURAL SLABS ON GRADE <br />-FROM BOTTOM OF SLAB <br />-FROM TOP OF SLAB <br />OTHER CONCRETE NOT EXPOSED TO WEATHER OR <br />EARTH FOR #11 BARS AND SMALLER <br />COVER <br />3" <br />2" <br />1 1/2" <br />1" <br />1" <br />2" <br />1 1/2" <br />1 1/2" <br />1. MASONRY UNITS SHALL DEVELOP THE FOLLOWING MINIMUM 28 DAY PRISM <br />COMPRESSIVE STRENGTHS IN ACCORDANCE WITH THE BUILDING CODE: <br />2. CONCRETE BLOCK SHALL CONFORM TO ASTM C90 MEDIUM WEIGHT. CLAY <br />BRICK LOCK SHALL CONFORM TO ASTM C652 <br />3. PRISM TEST SHALL BE PERFORMED FOR MASONRY WITH f'm OVER 2000 PSI <br />FOR CBC 2105A.2 <br />4. VERTICAL REINFORCING SHALL BE FULL HEIGHT OF WALL AND SHALL BE <br />BRACED AT 6' - 8" MAXIMUM TO PREVENT MOVEMENT WHILE GROUTING. <br />5. HORIZONTAL REINFORCING SHALL BE IN BOND BEAM UNITS AND TIED <br />SECURELY TO VERTICAL REINFORCING. <br />6. DOWELS, ANCHORS, AND OTHER EMBEDDED ITEMS SHALL BE TIED SECURELY <br />IN PLACE TO PREVENT MOVEMENT WHILE GROUTING. WET SETTING OR <br />STABBING IS NOT ALLOWED. <br />7. MAXIMUM GROUT LIFTS SHALL NOT EXCEED 8' - 0" AND CLEANOUTS AT THE <br />BOTTOM OF ALL CELLS SHALL BE USED UNLESS THE LIFT IS 4' - 0" OR LESS. THE <br />CLEANOUTS SHALL BE SEALED BEFORE GROUTING. GROUT FOR EACH <br />PLACEMENT SHALL BE STOPPED 1 1/2" BELOW THE TOP OF A BLOCK COURSE <br />EXCEPT AT THE FINAL COURSE. ALL GROUT SHALL BE THOROUGHLY <br />CONSOLIDATED BY VIBRATING IMMEDIATELY AFTER PLACING. SHAKING OR <br />RODDING REBAR IS NOT ALLOWED. FILL ALL CELLS WITH GROUT. <br />8. BLOCK SHALL BE PLACED IN RUNNING BOND AND SHALL BE 8"x8"x16" NOMINAL <br />UNITS, UNO. WHERE BLOCK IS REQUIRED TO BE PLACED IN STACK BOND (SEE <br />ARCH), OPEN-ENDED UNITS (I.E., "SPEED BLOCK") SHALL BE USED. <br />9. THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING THE SAFETY OF LIFT <br />HEIGHT FOR OPEN ENDED OR FIELD MODIFIED BLOCKS. <br />10. LAYOUT OF MASONRY BLOCK UNITS SHALL BE RUNNING BOND, U.N.O. BLOCK <br />MODULES/MORTAR JOINTS SHOWN ON THESE DRAWINGS ARE FOR <br />PRESENTATION PURPOSES ONLY, AND NOT INTENDED TO SUPERSEDE <br />ARCHITECTURAL DESIGN REQUIREMENTS. <br />11. WALL REINFORCEMENT SEE PLANS & ELEVATIONS <br />12. PROVIDE VERTICAL CONTROL JOINTS IN CMU WALLS AS SHOWN ON PLAN. <br />UNLESS NOTED OTHERWISE VERTICAL CONTROL JOINTS SHALL OCCUR AT <br />25' - 0" O.C. MAXIMUM ALONG WALL LENGTH, AT FOUNDATION STEPS, FLOOR <br />OR ROOF JOINTS, WALL HEIGHT CHANGES, AND 24" MINIMUM PAST ONE SIDE <br />OF OPENINGS > 6' - 0" WIDE, U.N.O. ON PLANS <br />13. WHEN THE AMBIENT TEMPERATURE FALLS BELOW 40°F, OR EXCEEDS 100°F, <br />PROVSIONS OF TMS602 / ACI 530 / ASCE6. ARTICLE 1.8C OR ARTICLE 1.8D SHALL <br />BE IMPLEMENTED. <br />MASONRY NOTES: <br />MINIMUM 28 DAY COMPRESSIVE STRENGTH <br />LOCATION fm <br />TYPE S <br />MORTAR <br />PER ASTM C270 <br />GROUT <br />PER CBC 2103A.3 <br />ALL MASONRY U.N.O 2000 PSI 1800 PSI 2000 PSI <br />REGISTERED PROF ESS IONAL <br />ENGINEERNo. <br />Exp.9/30/24 <br />S4029 <br />YOUNG-K E UN NAM <br />STATE OF CAL IFORNIA <br />ST R U C T U R AL <br />E N G I N E E R S I N CV C A <br />2151 Michelson Dr. #240 <br />Irvine, CA 92612 <br />Tel. 949.679.0870 <br />Fax. 949.679.9370 <br />Project No.: i735 <br />C I V I LQuality <br />Service <br />Commitment <br />S T R U C T U R A L DBEMBE SBE <br />SCALE: <br />REVISIONS: <br />OW <br />N <br />E <br />R <br />: <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />N <br />A <br />M <br />E <br />: <br />CL <br />I <br />E <br />N <br />T <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />: <br />DATE ISSUED: <br />PROJECT NO: <br />100% CD 07/07/23 <br />REV. 1 08/21/23 <br />12" = 1'-0" <br />08/10/2023 <br />S0.1 <br />GENERAL NOTES <br />2022-40123 <br />CI <br />T <br />Y <br /> <br />O <br />F <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />NE <br />W <br />H <br />O <br />P <br />E <br /> <br />L <br />I <br />B <br />R <br />A <br />R <br />Y <br />MO <br />D <br />E <br />R <br />N <br />I <br />Z <br />A <br />T <br />I <br />O <br />N <br />12 <br />2 <br /> <br />N <br />. <br /> <br />N <br />E <br />W <br />H <br />O <br />P <br />E <br /> <br />S <br />T <br />. <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />DESCRIPTION DATE <br />122 N Newhope <br />Street4/16/2025