Laserfiche WebLink
SHEET NAME <br />SHEET SIZE <br />SHEET NUMBER <br />ANSI B <br />PV-8 <br />11" X 17" <br />MYNT SOLAR, INC. <br />(801) 349-6475 <br />Email - Service@myntsolar.com <br />www.myntsolar.com <br />MA <br />R <br />I <br />E <br />L <br />A <br /> <br />M <br />A <br />N <br />R <br />I <br />Q <br />U <br />E <br />Z <br /> <br />R <br />E <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />1 <br />1 <br />1 <br />8 <br /> <br />S <br /> <br />H <br />I <br />C <br />K <br />O <br />R <br />Y <br /> <br />S <br />T <br />. <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />, <br /> <br />U <br />S <br />A <br />AP <br />N <br /># <br /> <br />0 <br />1 <br />1 <br />0 <br />7 <br />5 <br />2 <br />8 <br />PHOTOVOLTAIC PROJECT INFO <br />UT <br />I <br />L <br />I <br />T <br />Y <br />: <br />S <br />C <br />E <br />PV MODULE: <br />INVERTER: <br />(9) HANWHA Q.PEAK DUO BLK <br />ML-G10+ 400 <br />(5) AP SYSTEM DS3-S <br />MICROINVERTERS(240V) <br />3.60 kW (DC) / 3.20 kW (AC) <br /> ARRAY1 AZIMUTH: 180° <br />CEC 2022 / CRC 2022 / CBC 2022 <br />PROJECT NAME <br />04-19-2023 <br />REV. BYDATE <br />ARRAY TILT: 18° <br /> ARRAY2 AZIMUTH: 270° <br />ADDITIONAL NOTES <br /> <br />· ALL MATERIALS, EQUIPMENT, INSTALLATION AND WORK SHALL COMPLY WITH THE FOLLOWING APPLICABLE CODES: <br />- 2022 CBC <br />- 2022 CRC <br />- 2022 CEC <br />- 2022 CMC <br />- 2022 CPC <br />- 2022 CFC <br />- 2022 CEC <br />· ALL EQUIPMENT SHALL BE LISTED AND LABELED BY A RECOGNIZED TESTING LABORATORY AND INSTALLED PER THE LISTING REQUIREMENTS AND THE <br /> MANUFACTURER' S INSTRUCTIONS, CEC 110.2, 110.3, 690.4(B) AND 690.12(5). <br />· ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED, INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND SWITCHES. <br />· ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH CEC ARTICLE 250. <br />· ALL PV CIRCUITS CONCECTED TO MORE THAN ONE SOURCE SHALL HAVE OVERCURRENT DEVICE LOCATED SO AS TO PROVIDE OVERCURRENT PROTECTION <br /> FROM ALL SOURCES, CEC 690.9(A). <br />· ALL EQUIPMENT OF THE PV SYSTEM (INCLUDING RAPID SHUTDOWN INITIATION) SHALL BE LOCATED NEAR THE MAIN ELECTRICAL SERVICE EQUIPMENT, CEC <br /> 690.13, 690.15. <br />· RAPID SHUTDOWN EQUIPMENT TO PROVIDE CONTROLLED CONDUCTORS THAT ARE MORE THAN 5 FEET IN LENGTH INSIDE A BUILDING OR MORE THAN 10 <br /> FEET FROM A PV ARRAY LIMITATION TO NOT MORE THAN 30 VOLTS AND 240 VOLT-AMPERES WITHIN 30 SECONDS OF RAPID SHUTDOWN INITIATION, CEC <br /> 690.12. <br />· THE UTILITY-INTERACTIVE INVERTERS SHALL AUTOMATICALLY DE-ENERGIZE ITS OUTPUT TO THE CONCECTED ELECTRICAL PRODUCTION AND DISTRIBUTION <br /> NETWORK UPON LOSS OF VOLTAGE IN THE SYSTEM AND SHALL REMAIN IN THAT STATE UNTIL THE ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK <br /> VOLTAGE HAS BEEN RESTORED, CEC 690.61 & 705.40. <br />· DUE TO THE FACT THAT PV MODULES ARE ENERGIZED WHENEVER EXPOSED TO LIGHT, PV CONTRACTOR SHALL DISABLE THE ARRAY DURING INSTALLATION <br /> AND SERVICE BY SHORT CIRCUITING, OPEN CIRCUITING, OR COVERING THE ARRAY WITH OPAQUE COVERING, CEC 690.18. <br />· ALL CONDUCTOR EXPOSED TO WEATHER SHALL BE LISTED AND IDENTIFIED FOR USE IN DIRECT SUNLIGHT, CEC310.0(D) AND 690.31(C) THROUGH (G). <br />· ALL CONDUCTORS TO BE MATERIAL APPROVED BY THE CODE AND THEIR INSULATIONS TO BE RATED TO NOT LESS THAN 90°C 600-VOLTS MINIMUM. <br />· INSULATION OF EXPOSED CONDUCTORS UNDER THE MODULES SHALL BE USE-2 OR PV-WIRE TYPE FOR GROUNDED DC SYSTEMS, CEC 690.31(B), AND <br /> PV-WIRE TYPE FOR UNGROUNDED DC SYSTEM, (AS IN TRANSFORMER LESS INVERTERS OR MICROINVERTERS WITH ISOLATED GROUNDS), CEC 690.35(D). <br />· FINE-STRANDED CABLE CONCECTIONS MUST BE MADE IN LUGS AND TERMINALS LISTED AND MARKED FOR THE USE, CEC 110.14 & 690.74(A). <br />· ALL PV CIRCUIT CONDUCTORS SHALL BE MARKED ON EACH END FOR UNIQUE IDENTIFICATION, CEC 690.31(B). <br />· ALL GROUNDED, (NEUTRAL), CONDUCTORS' INSULATION SHALL BE SOLID WHITE, GRAY OR WITH 3-WHITE STRIPES, CEC 200.6, 200.7, & 400.22, AND ALL <br /> GROUNDED CONDUCTORS SHALL BE OF BARE WITHOUT COVERING, OR WITH INSULATION OF GREEN OR GREEN WITH YELLOW STRIPES, CEC 250.119 & <br /> 400.23. THE COLOR OF UNGROUNDED CONDUCTORS SHALL BE OTHER THAN FOR GROUNDED, (NEUTRAL), AND GROUNDING CONDUCTORS, CEC 310.110(C). <br />SOLAR PHOTOVOLTAIC SYSTEM NOTES <br />Structural Only <br />R E G I S T E R E D P R O F E S S I O N A L E N G I N E E R <br />C I V I L <br />No. C70784 <br />Exp. 06/30/2025 <br />S T A T E O F C A L I F O R N IA <br />PHONG TRU ONG <br />1118 S Hickory St <br />06/05/23