Laserfiche WebLink
9'-4" 24'-6" 7'-0"2" <br /> <br />1 <br />2 <br />' <br />- <br />7 <br />" <br /> <br />4' <br />- <br />5 <br />" <br />1 <br />0 <br />' <br />- <br />9 <br />" <br />3' <br />- <br />5 <br />" <br />1 <br />5 <br />' <br />- <br />7 <br />" <br /> <br />8'-9" 6'-2" 7" <br />MSPUM ACD ACB <br />JB <br />ROOF PLAN WITH MODULES <br />SCALE: 3/32" = 1'-0"1 <br />SHEET NAME <br />SHEET SIZE <br />SHEET NUMBER <br />ANSI B <br />PV-2 <br />11" X 17" <br />MYNT SOLAR, INC. <br />(801) 349-6475 <br />Email - Service@myntsolar.com <br />www.myntsolar.com <br />MA <br />R <br />I <br />E <br />L <br />A <br /> <br />M <br />A <br />N <br />R <br />I <br />Q <br />U <br />E <br />Z <br /> <br />R <br />E <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />1 <br />1 <br />1 <br />8 <br /> <br />S <br /> <br />H <br />I <br />C <br />K <br />O <br />R <br />Y <br /> <br />S <br />T <br />. <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />, <br /> <br />U <br />S <br />A <br />AP <br />N <br /># <br /> <br />0 <br />1 <br />1 <br />0 <br />7 <br />5 <br />2 <br />8 <br />PHOTOVOLTAIC PROJECT INFO <br />UT <br />I <br />L <br />I <br />T <br />Y <br />: <br />S <br />C <br />E <br />PV MODULE: <br />INVERTER: <br />(9) HANWHA Q.PEAK DUO BLK <br />ML-G10+ 400 <br />(5) AP SYSTEM DS3-S <br />MICROINVERTERS(240V) <br />3.60 kW (DC) / 3.20 kW (AC) <br /> ARRAY1 AZIMUTH: 180° <br />CEC 2022 / CRC 2022 / CBC 2022 <br />PROJECT NAME <br />04-19-2023 <br />REV. BYDATE <br />ARRAY TILT: 18° <br /> ARRAY2 AZIMUTH: 270° <br />ROOF PLAN WITH <br />MODULES <br />· ALL EQUIPMENT AND CONDUITS SHALL BE PAINTED TO MATCH <br /> THE BACKGROUND COLOR OF THAT LOCATION. <br />· PLUMBING VENTS, SKYLIGHTS AND MECHANICAL VENTS SHALL <br /> NOT BE COVERED, MOVED, RE-ROUTED OR RE-LOCATED. <br />74.0" <br /> 4 <br />1 <br />. <br />1 <br />" <br /> <br />36 <br />" <br /> <br />FIRE CODE SETBACKS <br />NOTE: <br />THIS PLAN CHECK IS FOR SOLAR PHOTOVOLTAIC ONLY. OTHER <br />STRUCTURES ON SITE ARE NOT A PART OF REVIEW. <br />1 <br />8 <br />" <br />FIRE CODE SETBACKS <br />M <br />ROOF # OF <br />MODULES <br />ARRAY <br />AREA <br />(Sq. Ft.) <br />ROOF <br />AREA <br />(Sq. Ft.) <br />ROOF <br />AREA <br />COVERED <br />BY ARRAY <br />(%) <br />#1 8 168.96 354.01 47.73 <br />#2 1 21.12 275.80 7.66 <br />ROOF DESCRIPTION <br />ROOF TYPE ASPHALT SHINGLE <br />ROOF ROOF <br />TILT AZIMUTH TRUSSES <br />SIZE <br />TRUSSES <br />SPACING <br />#1 18° 180° 2"x6" 24" O.C. <br />#2 18° 270° 2"x6" 24" O.C. <br />2"X6" TRUSSES @ 24" O.C. (TYP.) <br />MODULE TYPE, DIMENSIONS & WEIGHT <br />NUMBER OF PANELS IN ARRAY = 9 MODULES <br />MODULE TYPE = HANWHA Q.PEAK DUO BLK ML-G10+ 400 (400W) MODULES <br />NUMBER OF CONNECTIONS TO ROOF = 23 <br />WEIGHT OF INDIVIDUAL PANEL = 48.5 LBS / 22.0 KG. <br />MOUNTING SYSTEM WEIGHT : 1.5 LBS. PER MODULE <br />TOTAL WEIGHT OF ARRAY: 450.00 LBS. <br />WEIGHT AT EACH CONCECTION : 450.00 LBS / 23 = 19.57 LBS <br />SOLAR PANEL AREA = 74.0"X 41.1 " = 21.12 SF <br />TOTAL ARRAY AREA = 9 X 21.12 = 190.08 <br />DISTRIBUTED LOAD = 450.00/190.08= 2.37 PSF <br />3/4" OR GREATER EMT <br />CONDUITRUN (1/2 INCHES <br />ABOVE ROOF) <br />(N) JUNCTION BOX <br />(E <br />) <br /> <br />B <br />A <br />C <br />K <br /> <br />Y <br />A <br />R <br />D <br />(N) IRONRIDGE XR10 RAILS 168" <br />(23) IRONRIDGE FLASH FOOT2 <br />ATTACHMENTS @ 48" O.C. <br />PHOTOVOLTAIC MODULES <br />HANWHA Q.PEAK DUO BLK <br />ML-G10+ 400 (400W) <br />(5) AP SYSTEM DS3-S <br />MICROINVERTERS(240V) <br />(E) UTILITY METER <br />(N) AC COMBINER BOX <br />(E) MAIN SERVICE PANEL, 200 <br />(N) AC DISCONNECTROOF #2 <br />(01) HANWHA Q.PEAK DUO BLK ML-G10+ <br />400 (400W) MODULES <br />(E <br />) <br /> <br />F <br />R <br />O <br />N <br />T <br /> <br />Y <br />A <br />R <br />D <br />S <br />H <br />I <br />C <br />K <br />O <br />R <br />Y <br /> <br />S <br />T <br />. <br />ROOF #1 <br />(08) HANWHA Q.PEAK DUO BLK ML-G10+ <br />400 (400W) MODULES <br />Structural Only <br />R E G I S T E RE D P R O F E S S I O N A L E N G I N E E R <br />C I V I L <br />No. C70784 <br />Exp. 06/30/2025 <br />S T A T E O F C A L I F O R N IA <br />PHONG TRUONG <br />1118 S Hickory St <br />06/05/23