Laserfiche WebLink
RE <br />F <br />(GAS) <br />S <br />S <br />S <br />S <br />S <br />S <br />S <br />S <br />S <br />S <br />S <br />S <br />S <br />S <br />CW <br /> <br />CW <br />CW <br /> <br />CW <br /> <br />CW <br /> <br />CW <br /> <br />CW <br /> <br />CW <br /> <br />CW <br /> <br />CW <br /> <br />G <br />G <br />G <br />G <br />G <br />G <br />G <br />G <br />G <br />G <br />G <br />G <br />CW <br />CW <br />CW <br />CW <br />CW <br />CW <br /> <br />CW <br />G G <br />G <br />G <br />S <br />S <br />S <br />7 <br />18 <br />7 <br />8 <br />6' <br />- <br />6 <br />" <br /> <br />16 <br />' <br />- <br />1 <br />1 <br /> <br />1 <br />/ <br />2 <br />" <br /> <br />35 <br />' <br />- <br />1 <br />" <br /> <br />89 <br />' <br />- <br />2 <br />" <br />39 <br />' <br />- <br />6 <br />" <br />19 <br />' <br />- <br />0 <br />" <br /> <br />23 <br />' <br />- <br />8 <br />" <br /> <br />42 <br />' <br />- <br />1 <br />" <br /> <br />16 <br />' <br />- <br />1 <br />1 <br /> <br />1 <br />/ <br />2 <br />" <br /> <br />50'-0" <br />37'-0"3'-0" 10'-0" 3'-0" <br />27'-10" 19'-2" 3'-0" <br />5'-6" 36'-0" 8'-6" <br />PROPERTY LINE 50.00' <br />CENTER LINE OF STREET <br />(E) MAIN HOUSE <br />1,135 SF <br />1313 ENGLISH ST <br />(E) KITCHEN <br />(E) LIVING <br />(E) BED 1 <br />(E) <br />DRIVEWAY <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br /> <br />1 <br />4 <br />1 <br />. <br />1 <br />9 <br />' <br />PROPERTY LINE 50.00' <br />2 <br />2 <br />(E) BED 2 <br />(E) BATH 1 <br />(E) DINING <br />(E <br />) <br /> <br />5 <br />: <br />1 <br />2 <br /> <br />SL <br />O <br />P <br />E <br /> <br />(E <br />) <br /> <br />5 <br />: <br />1 <br />2 <br />SL <br />O <br />P <br />E <br />20 <br />(E) HOUSE <br />ENTRY <br />65 SF <br />(E) GARAGE <br /> 337 SF <br />(E <br />) <br /> <br />C <br />L <br />O <br />S <br />E <br />T <br /> <br />13 <br />(E) 3/4" WATER <br /> METER <br />2 <br />(E <br />) <br /> <br />C <br />L <br />O <br />S <br />E <br />T <br />(E) UTILITY <br />POLE <br />SIDEWALK <br />LINE OF CURB <br />(E) HALLWAY <br />(E) LAUNDRY <br />ENGLISH ST <br />19 <br />5' TALL BLOCK WALL <br />(E) ELEC <br />METER <br />(E) DRIVEWAY <br />APPROACH <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br /> <br />1 <br />4 <br />1 <br />. <br />1 <br />9 <br />' <br />2 <br />(E) BED 3 <br />(E) 5:12 <br />SLOPE <br />(E) 5:12 <br />SLOPE <br />(E) 5:12 <br />SLOPE <br />(E) 5:12 <br />SLOPE <br />4 <br />14 <br />1 <br />' <br />- <br />2 <br /> <br />1 <br />/ <br />2 <br />" <br />5' <br /> <br />T <br />A <br />L <br />L <br /> <br />B <br />L <br />O <br />C <br />K <br /> <br />W <br />A <br />L <br />L <br />(E) GAS <br />METER <br />9 <br />P. <br />U <br />. <br />E <br />. <br />5' <br />- <br />0 <br />" <br /> <br />5FT EASEMENT <br />16 <br />6' <br />- <br />8 <br />" <br />9'-7 1/2" <br />5' <br /> <br />P <br />. <br />U <br />. <br />E <br />. <br />EASEMENT <br />5'-0" <br />PROPERTY LINE 50.00' <br />CENTER LINE OF STREET <br />(E) MAIN HOUSE <br />1,135 SF <br />1313 ENGLISH ST <br />(E) KITCHEN <br />(E) LIVING <br />(E) BED 1 <br />(E) <br />DRIVEWAY <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br /> <br />1 <br />4 <br />1 <br />. <br />1 <br />9 <br />' <br />PROPERTY LINE 50.00' <br />2 <br />2 <br />(E) BED 2 <br />(E) BATH 1 <br />(E) DINING <br />(E <br />) <br /> <br />5 <br />: <br />1 <br />2 <br /> <br />SL <br />O <br />P <br />E <br /> <br />(E <br />) <br /> <br />5 <br />: <br />1 <br />2 <br />SL <br />O <br />P <br />E <br />23 <br />(E) HOUSE <br />ENTRY <br />65 SF <br />(E) GARAGE <br /> 337 SF <br />(E <br />) <br /> <br />C <br />L <br />O <br />S <br />E <br />T <br /> <br />13 <br />(E) 3/4" WATER <br /> METER <br />2 <br />(E <br />) <br /> <br />C <br />L <br />O <br />S <br />E <br />T <br />(E) UTILITY <br />POLE <br />SIDEWALK <br />LINE OF CURB <br />(E) HALLWAY <br />(E) LAUNDRY <br />ENGLISH ST <br />19 <br />5' TALL BLOCK WALL <br />(E) ELEC <br />METER <br />(E) DRIVEWAY <br />APPROACH <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br /> <br />1 <br />4 <br />1 <br />. <br />1 <br />9 <br />' <br /> <br />2 <br />(E) BED 3 <br />(E) 5:12 <br />SLOPE <br />(E) 5:12 <br />SLOPE <br />(E) 5:12 <br />SLOPE <br />(E) 5:12 <br />SLOPE <br />4 <br />50'-0" <br />SIDE BACK <br />6'-0"40'-0" <br />SIDE BACK <br />4'-0" <br />23 <br />' <br />- <br />1 <br />1 <br /> <br />1 <br />/ <br />2 <br />" <br /> <br />28 <br />' <br />- <br />1 <br />" <br /> <br />84 <br />' <br />- <br />1 <br />1 <br /> <br />1 <br />/ <br />2 <br />" <br /> <br />SI <br />D <br />E <br /> <br />S <br />E <br />T <br />B <br />A <br />C <br />K <br />4' <br />- <br />3 <br />" <br />13 <br />' <br />- <br />1 <br />0 <br />" <br /> <br />3' <br />- <br />1 <br /> <br />1 <br />/ <br />2 <br />" <br /> <br />42 <br />' <br />- <br />1 <br />" <br /> <br />23 <br />' <br />- <br />8 <br />" <br /> <br />19 <br />' <br />- <br />0 <br />" <br /> <br />16 <br />' <br />- <br />0 <br />" <br /> <br />19 <br />' <br />- <br />3 <br /> <br />1 <br />/ <br />2 <br />" <br /> <br />SE <br />T <br />B <br />A <br />C <br />K <br />4' <br />- <br />3 <br />" <br />(N) 5:12 <br />SLOPE <br />(N) 5:12 <br />SLOPE <br />(N <br />) <br /> <br />5 <br />: <br />1 <br />2 <br />SL <br />O <br />P <br />E <br /> <br />(N <br />) <br /> <br />5 <br />: <br />1 <br />2 <br />SL <br />O <br />P <br />E <br />17 <br />(E) SEWER <br />LATERAL <br />V.I.F. <br />* <br />5% <br /> <br />S <br />L <br />O <br />P <br />E <br />5% <br /> <br />S <br />L <br />O <br />P <br />E <br />5% SLOPE 5% SLOPE <br />18 <br />12 <br />WATER <br />P.O.C <br />SEWER <br />P.O.C <br />10 <br />5 <br />6 <br />GAS <br />P.O.C <br />BEGIN CONSTRUCTION <br />MEASUREMENT AT THIS CORNER <br />SCE <br />MSR# <br />1.1 1 14 <br />REFER TO SECTION <br />A-A GRADING <br />DRAINAGE AROUND <br />THE FOUNDATION <br />A <br />A <br />5% SLOPE <br />5% SLOPE <br />2% SLOPE <br />2% SLOPE <br />2% <br /> <br />S <br />L <br />O <br />P <br />E <br /> <br />2% <br /> <br />S <br />L <br />O <br />P <br />E <br />5% <br /> <br />S <br />L <br />O <br />P <br />E <br />5% <br /> <br />S <br />L <br />O <br />P <br />E <br />eave <br />1'-0" <br />eave <br />1'-0" <br />ea <br />v <br />e <br />1' <br />- <br />0 <br />" <br />eave <br />1'-0" <br />eave <br />1'-0" <br />ea <br />v <br />e <br />1' <br />- <br />0 <br />" <br />(N) BED 1 <br />(N) BED 2 <br />(N) BATH 1 <br />(N) LIVING <br />(N) BATH 2 <br />(N) W.I.C(N) KITCHEN <br />(N) W.I.C <br />(N) DINING <br />5' <br /> <br />T <br />A <br />L <br />L <br /> <br />B <br />L <br />O <br />C <br />K <br /> <br />W <br />A <br />L <br />L <br />(E) GAS <br />METER <br />27'-10" 19'-2"3'-0" <br />(N) ADU <br />893 SF <br />1313 ENGLISH ST <br />UNIT 2 <br />25 <br />' <br />- <br />0 <br />" <br />FOR OPEN SPACE <br />695 SF <br />FOR OPEN SPACE <br />332 SF <br />22'-2" <br />27'-10" <br />ea <br />v <br />e <br /> <br />6" <br /> <br />ea <br />v <br />e <br />6" <br />14 <br />1 <br />' <br />- <br />2 <br /> <br />1 <br />/ <br />2 <br />" <br />15 <br />9 <br />7 <br />11 <br />(N) 1'' WATER METER 3' <br />AWAY FROM EDGE OF <br />DRIVEWAY AND AT <br />MINIMUM 2FT FROM THE <br />EXISTING WATER METER <br />1.5 INCHES NEW <br />WATER LINE, MIN. 18 <br />INCHES BURIAL DEPTH <br />AND TRACE WIRE IS <br />REQUIRED FOR PVC <br />WATER LINES <br />20 <br />** <br />* <br />(N) W/D <br />(N) ADU <br />ENTRY <br />PORCH <br />P. <br />U <br />. <br />E <br />. <br />5' <br />- <br />0 <br />" <br /> <br />5FT EASEMENT <br />16 <br />5' <br /> <br />P <br />. <br />U <br />. <br />E <br />. <br />EASEMENT <br />5'-0"10 <br />A-07 <br />10 <br />A-07 <br />LEGAL DESCRIPTION <br />ASSESSORS PARCEL NO. APN: 405-101-31 <br />P-BOOK: 385 PAGE: 16 PAR: 2 <br />NOT IN FLOOD FEMA SHFA'S = FLOOD ZONE X <br />LOT SIZE 7,060 SF <br />ZONE R-1 RESIDENTIAL <br />EXISTING SFR GARAGE 337 SF <br />EXISTING SFR HOUSE 1,135 SF <br />EXISTING SFR PORCH 65 SF <br />NEW ADU PORCH 45 SF <br />NEW ADU 893 SF <br />TOTAL 2,475 SF <br />LOT COVERAGE = 2,475 SF / 7,060 SF = 35% OK <br />OCCUPANCY GROUP R3 / U <br />CONSTRUCTION TYPE V-B <br />FIRE SPRINKLER SFR = NO; ADU = NO <br />VICINITY MAP PROJECT DATAGENERAL NOTESSITE PLAN NOTES <br />1. DEMOLITION CONTRACTOR SHALL RELOCATE REUSABLE MATERIALS TO DESIGNATED <br />SALVAGE AREA, NON-USABLE MATERIALS SHALL BE PLACED APPROPRIATELY IN REFUSE <br />BIN AND SHALL BE COVERED AT NIGHT AND DURING RELATIVE HIGH WINDS, RAIN, <br />ETC...REFUSE BIN SHALL BE COVERED DURING TRANSFER TO AND FROM DUMP SITE. <br />CONTRACTOR TO BE LIABLE FOR REFUSE SPILLING. ALL DEBRIS TO BE HAULED AWAY <br />AND CLEAN-UP SHALL BE COMPLETED TO BROOM FINISH. EXISTING MATERIALS AND/OR <br />STRUCTURE TO REMAIN SHALL BE PROTECTED FROM DUST, PAINT CHIPPING, ETC..., BY <br />USE OF PLASTIC OR WHATEVER IS REQUIRED FOR PROPER PROTECTION. EXISTING <br />STRUCTURES SHALL HAVE BRACING AND SHORING AS REQUIRED TO PROTECT THE <br />EXISTING STRUCTURE. PROVIDE DE-WATERING FACILITIES FOR CONSTRUCTION AS <br />REQUIRED. COORDINATE AS-BUILT INFORMATION, STRUCTURAL, ETC. TO <br />DESIGNER/ENGINEER AS REQUIRED. <br />2. THE DISCHARGE OF POLLUTANTS TO ANY STORM DRAINAGE SYSTEM IS PROHIBITED. <br />NO SOID WASTE, PETROLEUM BYPRODUCTS, SOIL PARTICULATE, CONSTRUCTION WASTE <br />MATERIALS, OR WASTEWATER GENERATED ON CONSTRUCTION SITES OR BY <br />CONSTRUCTION ACTIVITIES SHALL BE PLACED, CONVEYED OR DISCHARGED INTO THE <br />STREET, GUTTER OR STORM DRAIN SYSTEM. <br />3. THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOTCLEAR AND UNOBSTRUCTED <br />ACCESS TO ANY WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES, PULL- <br />BOXES, TRANSFORMERS, VAULTS, PUMPS, VALVES, METERS, APPURTENANCES, ETC.) OR <br />TO THE LOCATION OF THE HOOK-UP. THE CONSTRUCTION SHALL NOT BE WITHIN TEN <br />FEET OF ANY POWER LINES - WHETHER OR NOT THE LINES ARE LOCATED ON THE <br />PROPERTY. FAILURE TO COMPLY MAY CAUSE CONSTRUCTION DELAYS AND/OR <br />ADDITIONAL EXPENSES. <br />4. WHEN UTILITIES METER ALTERATION / RELOCATION OCCUR, INSTALLATION <br />PROCEDURES SHALL BE VERIFIED AND APPROVED BY THE BUILDING INSPECTOR PRIOR <br />TO INSTALLATION. <br />5. NOTIFY AQMD FOR ASBESTOS REMOVAL PROCEDURE AND SUBMIT ASBESTOS REPORT <br />TO BUILDING DIVISION PRIOR TO DEMOLITION PERMIT ISSUANCE. <br />6. THE APPLICANT SHALL BE RESPONSIBLE FOR CONFIRMING ALL EXISTING UTILITY <br />EASEMENTS ON-SITE THAT MAY AFFECT THE PROJECT. THE SITE PLAN SHALL REFLECT <br />ALL RECORDED (OR NON-RECORDED) UTILITY EASEMENTS AND ENSURE THERE ARE NO <br />ENCROACHMENTS BY PROPOSED IMPROVEMENTS (WHICH INCLUDES ANY OVERHANGING <br />ROOF EAVES). THE SITE PLAN SHALL SHOW ALL EXISTING ABOVE-GROUND UTILITIES <br />SUCH AS POWER POLES/LINES OR OTHER. <br />1) THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOT CLEAR AND UNOBSTRUCTED ACCESS TO ANY <br />WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES, PULL-BOXES, TRANSFORMERS, VAULTS, PUMPS, <br />VALVES, METERS, ETC) OR TO THE LOCATION OF THE HOOK-UP. THE CONSTRUCTION SHALL NOT BE WITHIN <br />TEN FEET OF ANY POWER LINES-WHETHER OR NOT THE LINES ARE LOCATED ON THE PROPERTY. FAILURE TO <br />COMPLY MAY CAUSE CONSTRUCTION DELAYS AND/ OR ADDITIONAL EXPENSES. <br />2) AN APPROVED SEISMIC GAS SHUTOFF VALVE WILL BE INSTALLED ON THE FUEL GAS LINE ON THE DOWN <br />STREAM SIDE OF THE UTILITY METER AND BE RIGIDLY CONNECTED TO THE EXTERIOR OF THE BUILDING OR <br />STRUCTURE CONTAINING THE FUEL GAS PIPING. <br />3) PROVIDE LOW CONSUMPTION WATER CLOSETS FOR ALL NEW CONSTRUCTION. EXISTING SHOWER HEADS <br />AND TOILETS MUST BE ADAPTED FOR LOW WATER CONSUMPTION. <br />4) PROVIDE 72" HIGH NON-ABSORBENT WALL ADJACENT TO SHOWER AND APPROVED SHATTER-RESISTANT <br />MATERIALS FOR SHOWER ENCLOSURE. <br />5) ALL CONSTRUCTION WASTE AND DEBRIS MUST BE CONTAINERIZED AT ALL TIMES <br />7) FINAL APPROVAL REQUIRED BY THE PUBLIC WORKS DEPARTMENT FOR STREET IMPROVEMENTS, CURB <br />CORES, CURB/GUTTERS, ETC. SEPARATE PUBLIC WORKS PERMIT REQUIRED FOR DRIVEWAYS, APPROACH TO <br />DRIVEWAY, SEWER LATERALS AND ANY WORK IN RIGHT OF WAY. <br />8) ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES AND <br />AMENDMENTS. <br />9) A SURVEY SHALL BE PROVIDED BY A LICENSED SURVEYOR ON STRUCTURES WHICH DEFINE PROPERTY <br />LINES, SET BACKS, DESIGNATED PARKLAND OR STREET RIGHT-OF-WAY. <br />10) DUST CONTROL MEASURES SHALL BE MAINTAINED THROUGHOUT THE DURATION OF THE PROJECT. <br />11) WATER HEATER MUST BE STRAPPED TO WALL; SEE DETAIL ON SHEET A-07. <br />12) PROVIDE ULTRA FLUSH WATER CLOSETS FOR ALL NEW CONSTRUCTION. EXISTING SHOWER HEADS AND <br />TOILETS MUST BE ADAPTED FOR WATER CONSUMPTION. <br />13) LAG BOLTS: PROVIDE LEAD HOLE 40%-70% OF THREADED SHANK DIA. AND FULL DIA. FOR SMOOTH SHANK <br />PORTION. 91 NDS <br />14) BLOCKING. ROOF RAFTERS AND CEILING JOINTS SHALL BE SUPPORTED LATERALLY TO PREVENT <br />ROTATION & LATERAL DISPLACEMENT IN ACCORDANCE w/ THE PROVISIONS OF CH.8 & CH.6 <br />15) CONTRACTOR AND/OR OWNER SHALL VERIFY CONSTRUCTION SITE TO CONFIRM THAT THERE IS NO TRACE <br />OF DEMOLISHED SWIMMING POOL WITHIN 5 FT FROM PROPOSED PERIMETER OF THE CONSTRUCTION SITE. <br />OTHERWISE, THEY NEED TO SUBMIT SOIL COMPACTION REPORT FROM LICENSED SOIL ENGINEER TO <br />BUILDING INSPECTOR PRIOR TO FOUNDATION INSPECTION. <br />17) SHEAR WALLS, LATHING & PLASTER IN MATERIALS SHALL CONFORM TO THE STANDARDS LISTED IN CH.6 & <br />CH.7 CRC <br />18) ALL BOLT HOLES SHALL BE DRILLED 1/32 TO 1/16" OVERSIZED." ENGINEER MUST INCLUDE IN STRUCTURAL <br />OBSERVATION NOTES. <br />19) PROVIDE RAIN GUTTERS AND CONVEY RAIN WATER TO THE STREET. <br />21) CONCRETE 3000 PSI <br />22) PARALLEL BEAM E.2.0 PSL <br />23) UFER GROUND IS REQUIRED AT NEW ELECTRICAL SERVICE. <br />24) UNDERGROUND UTILITIES REQUIRED ON SITE PLAN AND SHOW FOR ELECTRICAL, CABLE TV. AND <br />TELEPHONE <br />25) ARC FAULT CIRCUIT INTERRUPTION PROTECTION IS REQUIRED FOR ALL BRANCH CIRCUITS PER 2019 <br />CRC210.12 SHALL BE AFCI PROTECTED <br />26) BATHROOMS, KITCHEN, GARAGE & OUTSIDE OUTLETS WILL BE GFCI PROTECTED RECEPTACLE OUTLETS. <br />27) WATER SAVING WATER CLOSET w/ 1.28 GALLONS PER FLUSH. <br />28) PROVIDE MECHANICAL VENTILATION FOR BATHROOMS AND LAUNDRY ROOMS WITHOUT OPENABLE <br />WINDOW. <br />29) GLAZING WHICH IS LESS THAN 60 INCHES FROM A FLOOR AND WITHIN A 24 INCH ARC OF A DOORWAY'S <br />VERTICAL EDGE MUST COMPLY WITH CH. 3 CRC <br />30) LANDINGS AT DOOR. LANDINGS SHALL HAVE A WIDTH NOT LESS THAN THE WIDTH OF THE STAIRWAY OR <br />THE DOOR, WHICHEVER IS GREATER. <br />31) EVERY SPACE INTENDED FOR HUMAN OCCUPANCY SHALL BE PROVIDED WITH NATURAL LIGHT IN <br />ACCORDANCE WITH SECTION R303.1 OR SHALL BE PROVIDE AN AVERAGE ILLUMINATION OF 6 FEET-CADLES <br />OVER THE AREA OF THE ROOM AT A HEIGHT OF 30" ABOVE THE FLOOR LEVEL. <br />32) THE CONTRACTOR SHALL EXAMINE AND BECOME FAMILIAR WITH ALL CONTRACT DOCUMENTS, SURVEY <br />THE PROPERTY AND BECOME FAMILIAR WITH THE EXISTING CONDITIONS AND SCOPE OF WORK. ALL COST <br />SUBMITTED SHALL BE BASED ON A THROUGH KNOWLEDGE OF ALL WORK AND MATERIALS REQUIRED. ANY <br />DISCREPANCY AND/OR UNCERTAINTY AS TO WHAT MATERIALS OR PRODUCT IS TO BE USED SHOULD BE <br />VERIFIED WITH THE OWNER OR ENGINEER OF RECORD. <br />33) DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALE. <br />34) IN THE EVENT A DISCREPANCY IS FOUND IN THE CONTRACT DOCUMENTS, THE OWNER AND THE <br />DESIGNERS/ENGINEERS SHALL BE NOTIFIED, IN WRITING, IMMEDIATELY. <br />PARKING REQUIREMENTS <br />NOTWITHSTANDING ANY OTHER LAW, A LOCAL AGENCY, WHETHER OR NOT IT HAS <br />ADOPTED AN ORDINANCE GOVERNING ACCESSORY DWELLING UNITS IN ACCORDANCE <br />WITH SUBDIVISION, SHALL NOT IMPOSE PARKING STANDARDS FOR AN ACCESSORY <br />DWELLING UNIT IN ANY OF THE FOLLOWING INSTANCES: <br />THE ACCESSORY DWELLING UNIT IS LOCATED WITHIN ONE-HALF MILE WALKING <br />DISTANCE OF PUBLIC TRANSIT. BUS STOP ID 5898 <br />PROJECT CONTACT <br />OWNERSHIP <br />IT IS THE SUBCONTRACTORS RESPONSIBILITY PRIOR TO OR DURING <br />CONSTRUCTION TO NOTIFY THE DESIGNERS OR JOB FOREMAN IN WRITING <br />OR IN VERBAL OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS <br />AND SPECIFICATIONS OF WHICH A SUBCONTRACTOR THOROUGHLY <br />KNOWLEDGEABLE WITH THE BUILDING CODES AND METHODS OF <br />CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN OR VERBAL <br />INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS <br />SHALL BE RECEIVED FROM THE DESIGNERS OR JOB FOREMAN PRIOR TO <br />THE SUBCONTRACTORS BEFORE PROCEEDING WITH THE WORK. THE <br />OWNERS WILL NOT BE RESPONSIBLE FOR ANY DEFECTS IN <br />CONSTRUCTION IF THESE PROCEDURES ARE NOT BEING FOLLOWED. <br />DESCRIPTIONDATE DELTA <br />A-01 <br />TITLE SHEET / <br />SITE PLANS / <br />ROOF PLANS <br />NE <br />W <br /> <br />D <br />E <br />T <br />A <br />C <br />H <br />E <br />D <br /> <br />A <br />D <br />U <br />13 <br />1 <br />3 <br /> <br /> E <br />N <br />G <br />L <br />I <br />S <br />H <br /> <br />S <br />T <br /> <br />U <br />N <br />I <br />T <br /> <br />2 <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />EX <br />I <br />S <br />T <br />I <br />N <br />G <br /> <br />M <br />A <br />I <br />N <br /> <br />H <br />O <br />U <br />S <br />E <br />13 <br />1 <br />3 <br /> <br /> E <br />N <br />G <br />L <br />I <br />S <br />H <br /> <br />S <br />T <br />. <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />DETACHED ADU: <br />2 BEDROOMS, <br />2 BATHROOMS, <br />LIVING, KITCHEN, <br />DINING, AND <br />LAUNDRY <br /> 01/31/2024 PLAN CHECK SUBMITTAL <br />LOAN PHAM <br />17021 BOLERO LN <br />HUNTINGTON BEACH, CA 92649 <br />PHONE: 714-614-6344 <br />EMAIL: LOANPHAM8888@YAHOO.COM <br />KHANH DAO <br />10448 SALINAS RIVER CIR <br />FOUNTAIN VALLEY, CA 92708 <br />PHONE: (714) 390-5154 <br />3/32" = 1'- 0" 2 EXISTING SITE PLAN / ROOF PLAN 3/32" = 1'-0" 1 PROPOSED SITE PLAN / ROOF PLAN <br />8' <br />SCALE : 3/32" = 1'-0" <br />0 16' 24' <br />3 VIEW-3D MAIN HOUSE & ADU <br />THE PROPOSED PROJECT IS A 893 SF ONE-STORY DETACHED <br />ACCESSORY DWELLING UNIT, 2 BEDROOMS, 2 BATHROOMS, <br />LIVING, KITCHEN, DINING, AND LAUNDRY. <br />LEGALIZE MAIN HOUSE CENTRAL AC UNIT <br />(UNDER A SEPARATE PERMIT) <br />SOLAR SYSTEM ON SEPARATE PERMIT. <br />SHEET INDEX <br />SCOPE OF WORK <br />A-01 TITLE SHEET / SITE PLANS / ROOF PLANS <br />A-02 CALGREEN MANDATORY MEASURES <br />A-03 CALGREEN MANDATORY MEASURES <br />A-04 MAIN HOUSE (E) FLOOR PLAN & (E) ELEVATION <br />A-05 ADU FLOOR PLAN & ELECTRICAL/LIGHTING PLAN <br />A-06 ADU ELEVATIONS & SECTIONS <br />A-07 WALL AND ROOF DETAILS <br />A-08 ARCHITECTURAL DETAILS <br />A-09 AGING-IN-PLACE / FALL PREVENTION NOTES & <br />FEATURES / ELECTRIC-READY REQUIREMENTS <br />A.10 DRAINAGE PLAN / CONSTRUCTION MANAGEMENT PLAN <br />A.11 SOIL REPORT <br />A.12 SOIL REPORT <br />A.13 SOIL REPORT <br />S0 STRUCTURAL NOTES <br />S1 FOUNDATION & FRAMING PLANS <br />SD1 FOUNDATION DETAILS <br />SD2 FRAMING DETAILS <br />T24-1 TITLE 24 ADU <br />T24-2 TITLE 24 ADU <br />THIS PROJECT SHALL COMPLY WITH THE FOLLOWING CODES: <br />2022 EDITION OF THE CALIFORNIA BUILDING CODE, <br />2022 EDITION OF THE CALIFORNIA RESIDENTIAL CODE, <br />2022 EDITION OF THE CALIFORNIA MECHANICAL CODE, <br />2022 EDITION OF THE CALIFORNIA PLUMBING CODE, <br />2022 EDITION OF THE CALIFORNIA ELECTRIC CODE, <br />2022 CALIFORNIA GREEN BUILDING STANDARDS CODE, <br />2022 CALIFORNIA ENERGY CODE (TITLE 24) AND, <br />CITY AMENDMENTS AND MUNICIPAL CODE. <br />APPLICABLE CODES <br />1 (N) MAIN ELEC PANEL 200AMP; <br />DUAL GANG METER; MIN. 20' UFER GROUND <br />SITE PLAN KEYNOTES <br />2 (E) PERIMETER FENCE / BLOCK WALL <br />3 (E) CONCRETE WALKWAY <br />4 (E) DRIVEWAY <br />5 <br />6 GAS P.O.C <br />7 (E) LANDSCAPE <br />8 (E) TREE <br />9 (E) AC UNIT <br />10 <br />11 (N) WATER HEATER <br />12 SPACE FOR SOLAR PANEL INSTALLATION <br />(SEPARATE FUTURE PERMIT) <br />SYMBOLS LEGEND <br />DRAINAGE DIRECTION AND SLOPE <br />PROPERTY LINE CORNER POINTS AND ELEVATION DATUM <br />KEYNOTE CALLOUTS <br />EXISTING WALL TO REMAIN AND NEW WALLS <br />WALL TO BE DEMOLISHED <br />2% <br /># <br />13 (E) GATE <br />14 <br />15 (N) AC UNIT <br />INVERTER / METERING EQUIPMENT & PATHWAY FOR ROUTING <br />FROM THE SOLAR ZONE TO THE MAIN SERVICE PANEL. <br />(N) MAILBOX FOR ACCESSORY DWELLING UNIT <br />ADJACENT TO MAIN HOUSE MAILBOX16 <br />PROPOSED LOCATION OF THE NATURAL GAS METER <br />TYPICALLY WITHIN FIVE FEET OF THE STRUCTURE’S <br />FRONT WALL BUT NOT CLOSER THAN ONE FOOT FROM <br />THE FRONT EDGE <br />17 <br />(E) MAIN HOUSE ELEC. METER TO BECOME <br />18 <br />(E) GAS METER19 <br />(E) WATER METER20 <br />SETBACKS INDICATE REQUIRED MINIMUM DISTANCE FROM <br />PROPERTY LINES. CONTRACTOR TO VERIFY ON SITE. <br />PV SYSTEM WILL BE UNDER A SEPARATE PERMIT <br />THE MAIN ELECTRICAL SERVICE PANEL RATING OF 200 AMPS. <br />THE MAIN SERVICE PANEL SHALL HAVE A MINIMUM BUSBAR A <br />DOUBLE POLE CIRCUIT BREAKER FOR A FUTURE SOLAR <br />ELECTRIC INSTALLATION. THE RESERVED SPACE SHALL BE <br />POSITIONED AT THE OPPOSITE (LOAD) END FROM THE INPUT <br />FEEDER LOCATION OR MAIN CIRCUIT LOCATION AND SHALL BE <br />PERMANENTLY MARKED AS "FOR FUTURE SOLAR ELECTRIC". <br />SEPARATE PERMIT <br />1.1 (N) ADU SUB ELEC PANEL 125 AMP <br />(N) MAIN HOUSE SUB ELEC PANEL 125 AMP <br />NEW ELECTRIC PANEL ON THE NEW HOUSE <br />IS UNDER SEPARATE PERMIT. <br />13.1 (N) GATE <br />(N) 1" WATER METER MINIMUM PER CITY <br />REQUIREMENTS <br />21 <br />NEW (1) 24" BOX CANOPY TREE <br />NEW (6) 5-GAL SHRUBS <br />NEW (10) 1-GAL SHRUBS <br />(E) GRASS <br />NEW PERMEABLE HARDSCAPE <br />STRUCTURE MATERIALS: <br />EXTERIOR WALLS - WHITE STUCCO <br />ROOF - GREY SHINGLES <br />NOTE: <br />ALL PLANT MATERIALS SELECTED FROM LA <br />COASTAL GARDENS AND WWW.BEWATERWISE.COM <br />ARE ACCEPTABLE DROUGHT TOLERANT PLANTS. <br />PROJECT DIRECTORY <br />DIG ALERT (811) IS TO BE CONTACTED AND THAT <br />COMPLIANCE WITH EXCAVATION SAFETY IN <br />ACCORDANCE WITH GOVERNMENT CODE 4216 WILL <br />BE FOLLOWED PRIOR TO ANY EXCAVATION TAKING <br />PLACE. <br />OWNER / CONTRACTOR ACKNOLEDGEMENT SIGNATURE: <br />_______________________________________________ <br />DIG ALERT 811 <br />LANDSCAPE LEGEND <br />WATER P.O.C <br />SEWER P.O.C <br />TO BE DEMOLISHED22 <br />PARK & REC <br />DEVELOPMENT FEE <br />CALCULATION <br />(ADU SF / SFD SF) <br />893 SF / 1135 SF = 0.79 <br />THE ADU SF / SFD SF RATIO IS FOR PARK & REC FEE <br />PURPOSE ONLY. THE APPLICANT IS RESPONSIBLE <br />FOR THE GIVEN “SFR SF” OF THE EXISTING PRIMARY <br />RESIDENCE; BUILDING SAFETY STAFF ARE NOT <br />RESPONSIBLE FOR THE ACCURACY OF THE GIVEN <br />“SFR SF”. <br />MECHANICAL, ELECTRICAL AND PLUMBING ARE NOT PART OF <br />THIS PLAN REVIEW AND APPROVAL. MEP ARE SUBJECT TO <br />BUILDING FIELD INSPECTION. <br />ID 5898 <br />OWNERSHIP: <br />LOAN PHAM <br />17021 BOLERO LN <br />HUNTINGTON BEACH, CA92649 <br />PHONE: 714-614-6344 <br />EMAIL: LOANPHAM8888@YAHOO.COM <br />DESIGNER: <br />BB BROTHERS CORP. <br />949 SOUTH COAST DR., SUITE 570 <br />COSTA MESA, CA 92626 <br />714-299-4770 <br />STRUCTURAL ENGINEER: <br />MICHAEL PHILIPS <br />14161 HAMMON PL. <br />WESTMINSTER, CA 92683 <br />714-213-1608 <br />SOIL ENGINEER: <br />PRIORITY ENGINEERING GROUP <br />335 E. BLUERIDGE AVE. <br />ORANGE, CA 92865 <br />TITLE 24: <br />TRANG HO <br />14161 HAMMON PL. <br />WESTMINSTER, CA 92683 <br />714-213-1608 <br /> 03/30/2024 PLAN CHECK RESUBMITTAL <br />THE BUILDING DIMENSIONS SHOWN ON THE SITE PLANS ARE <br />MEASURED TO THE FACE OF THE WALL STUCCO FINISHES. <br />WHEREAS THE BUILDING DIMENSIONS SHOWN ON THE FLOOR <br />PLANS ARE MEASURED TO THE FACE OF STUDS/CONCRETE <br />SLAB EDGES FOR CONSTRUCTION PURPOSES. <br />BLDG# 101118232 <br />APPROVALS <br />PLNG - P. Raj <br />BLDG - W. Lee <br />PD - B. Martin <br />1313 N English St <br />8/28/2024