Laserfiche WebLink
CEMENT PLASTER ASSEMBLY <br />WEATHER RESISTANT BARRIER <br />12" CONT. S.A.M.F., OF CONTROL JOINT <br />WD. STUD FRAMING, WHERE OCCUR <br />DOUBLE "V" CONTROL JOINT <br />WALL SHEATHING, S.S.D. <br />WOOD BACKING FOR ALL CONTROL JOINTS <br />AT ALL WOOD STUD LOCATIONS <br />CUT WIRE LATH AND WIRE TIE WIRE LATH <br />TO EACH FLANGE OF THE CONTROL JOIN. <br />NO NAILS, SCREWS OR STAPLES ALLOWED <br />AT CONTROL JOINT SO THAT THE <br />CONTROL JOINT CAN EXPAND AND <br />CONTRACT <br />CEMENT PLASTER ASSEMBLY <br />WEATHER RESISTANT BARRIER IN WATER <br />SHED FASHION O/ S.A.M.F. AND SOLID LEG OF <br />CONTROL JOINT <br />S.A.M.F. O/ W.R.B. BELOW <br />CONTROL JOINT, EXTEND 12" <br />ABOVE SHEATHING <br />WD. STUD FRAMING, WHERE OCCUR <br />SOLID LEG DOUBLE "V" CONTROL JOINT <br />WALL SHEATHING, S.S.D. <br />CUT WIRE LATH AND WIRE TIE WIRE LATH <br />TO BOTTOM FLANGE OF THE CONTROL <br />JOIN. NO NAILS, SCREWS OR STAPLES <br />ALLOWED. <br />CUTTED WIRE LATH TO BE INSTALLED ABOVE <br />LEG OF CONTROL JOINT WITHOUT <br />CONNECTION <br />(2 LAYERS) <br />STANDARD STUD LENGTHS: 92-5/8" OR 104-5/8" UNLESS <br />NOTED OTHERWISE <br />UL DESIGN NO. U356 <br />ONE HOUR RATED ASSEMBLY (EXPOSED TO FIRE ON INTERIOR FACE ONLY) <br />CONSTRUCTION FROM EXTERIOR SIDE: <br />1. STUCCO: INSTALLED IN ACCORDANCE WITH MFR. INSTRUCTIONS. <br />2. WOOD STRUCTURAL PANEL SHEATHING:7/16" MINIMUM THICKNESS, MINIMUM GRADE C-D OR <br />'SHEATHING' WITH VERTICAL JOINTS CENTERED ON WOOD STUDS AND HORIZONTAL JOINTS BACKED <br />WITH NOM 2 X 4 IN. WOOD BLOCKING. ATTACHED WITH 6D CEMENT COATED BOX NAILS AT 6" O.C. AT <br />EDGES OF PANEL AND 12" O.C. ALONG SUPPORTING STUDS. <br />3. INSULATION: FRICTION FIT BETWEEN STUDS EITHER UNFACED MINERAL FIBER INSULATION (WITH <br />MIN. DENSITY OF 3 PCF) OR ALUMINUM FOIL OR KRAFT PAPER FACED GLASS FIBER INSULATION (WITH <br />MIN. DENSITY OF 0.9 PCF) R-13 MINIMUM. <br />4. WOOD STUDS: NOM 2 X 4 IN. SPACED 16" O.C. WITH DOUBLE TOP PLATES AND SINGLE BOTTOM <br />PLATE. <br />5. GYPSUM BOARD: 5/8" THICK, 4 FT WIDE, APPLIED VERTICALLY AND NAILED TO STUDS AND BEARING <br />PLATES 7" O.C. WITH 6D CEMENT COATED NAILS, 1-7/8" LONG WITH 1/4" DIAMETER HEAD. <br />NOTE: RE: STRUCT. DRAWINGS FOR REQUIRED STUD SIZE, SPACING, SHEATHING, AND NAILING <br />PATTERNS. <br />WEATHER RESISTIVE BARRIER <br />2 <br />3 45 <br />1 ON MORTAR BED ON LATH <br />ONE LAYER 5/8" GYPSUM WALL BOARD EACH SIDE <br />2X4 WOOD STUD, RE: STRUCTURAL FOR WALL LOCATIONS <br />A <br />B <br />2X6 WOOD STUD, RE: STRUCTURAL FOR WALL LOCATIONS <br />ONE LAYER 5/8" GYPSUM WALL BOARD EACH SIDE <br />AT ALL WET WALLS PROVIDE WATER RESISTANT <br />GYPSUM BOARD <br />UNFACED GLASS-FIBER BATT ACOUSTIC INSULATION; FIT <br />SNUGLY IN GAPS AND FASTEN SECURELY TO HORIZONTAL <br />BRACING, R-19 AT 2X6 WALLS, R-15 AT 2X4 WALLS <br />(2) LAYERS WEATHER RESISTANT BARRIER ON <br />EXTERIOR GRADE SHEATHING, LAP INTO WEEP <br />SCREED <br />P.T. WOOD SILL INSTALLED OVER CONTINUOUS BEAD OF <br />SEALANT ALONG EXTERIOR EDGE OF CONCRETE AT SLAB <br />ON GRADE INSTALLATIONS <br />STUCCO SYSTEM ON LATH. INSTALL PER MFR. <br />RECOMMENDATIONS <br />GRADE WHERE OCCURS <br />WEEP SCREED W/ 3-1/2" MIN. VERTICAL LEG <br />EDGE OF FOUNDATION <br />SELF ADHERED FLASHING, EXTEND UP WALL 12" MIN. <br />CONTINUOUS SILL SEALER LOCATED <br />TOWARD OUTER EDGE <br />8" <br /> <br />M <br />I <br />N <br />. <br />6" <br /> <br />M <br />I <br />N <br />. <br />SELF ADHERED WATERPROOF WRB SYSTEMS <br />TAPE <br />THIS DETAIL DESCRIBES TYPICAL GENERAL ASSEMBLY COMPONENTS AND INSTALLATION <br />PROCEDURE. REFER TO ACTUAL CONDITIONS AND KEYED DETAILS FOR DIMENSIONS, <br />CONFIGURATIONS AND OTHER SPECIFICS OF THE WORK. <br />EXTERIOR STUCCO ASSEMBLY. INSTALL <br />PER MANUFACTURERS <br />RECOMMENDATIONS <br />GALVANIZED ZINC ALLOY WIRE <br />CORNER REINFORCEMENT RIGHT <br />ANGLE <br />12" SELF ADHERED FLASHING, <br />WRAP 6" MIN. AT CORNERS <br />(2) LAYERS WEATHER RESISTANT <br />BARRIER ON EXTERIOR GRADE <br />SHEATHING <br />WALL TYPE PER PLANS AND <br />SECTIONS <br />FR <br />A <br />M <br />I <br />N <br />G <br /> <br />/ <br /> <br />S <br />U <br />B <br />S <br />T <br />R <br />A <br />T <br />E <br />THIS DETAIL DESCRIBES TYPICAL GENERAL ASSEMBLY COMPONENTS AND INSTALLATION <br />PROCEDURE. REFER TO ACTUAL CONDITIONS AND KEYED DETAILS FOR DIMENSIONS, <br />CONFIGURATIONS AND OTHER SPECIFICS OF THE WORK. <br />EXTERIOR STUCCO ASSEMBLY. INSTALL PER <br />MANUFACTURERS RECOMMENDATIONS <br />GALVANIZED/ZINC ALLOY WIRE CORNER <br />REINFORCEMENT. RIGHT ANGLE <br />OUTSIDE CORNER, PLAN VIEW <br />PLASTER EDGE METAL TERMINATION CAULK <br />SEAL BLDG. PAPER EDGE INTO CHANNEL <br />SEALANT AND BACKER ROD - TO BE <br />RESILIENT AND COMPATIBLE WITH THE <br />MATERIALS BEING JOINED <br />DISSIMILAR BUILDING MATERIAL OR BUILDING <br />COMPONENT ADHERED TO SUBSTRATE OVER <br />BITUTHENE SHINGLED INTO WRB. <br />FRAMING / <br />SUBSTRATE <br />INSIDE CORNER, PLAN VIEW <br />JOINT AT DISSIMILAR MATERIAL <br />3/ <br />8 <br />" <br />WALL PER PLAN <br />SOFFIT FRAMING <br />(1) LAYER OF 5/8" GYP. BD. <br />2-1/2" LIGHT GAUGE METAL FRAMING <br />CONTINUE GYPSUM BOARD BEHIND <br />SOFFIT <br />CEILING ASSEMBLY <br />DUCT OR PIPES <br />ATTIC SPACE <br />PIPE DIA. VARIES <br />22 GA. GALV. MTL. COUNTER <br />FLASHING WEATHERBOARD W/ METAL <br />FLANGE & RUBBER GASKET, LAP W/ <br />ROOF SHINGLES. <br />ASPHALT COMPOSITION SHINGLE OVER <br />PIPE FLASHING <br />LAP SHINGLE UNDER FLASHING <br />GALV. METAL <br />BASE FLASHING <br />AT VENT <br />ROOF FRAMING & SHEATHING, <br />RE: STRUCT. <br />NOTE: <br />A 1/4" GAP TO BE PROVIDED BETWEEN EDGE OF SHINGLE AND RAISED PORTION OF PIPE FLASHING. <br />RE <br />: <br /> <br />M <br />E <br />C <br />H <br />. <br />ASPHALT SHINGLES <br />INSTALL PER MFR. RECOMMENDATIONS <br />WEATHER RESISTANT BARRIER ON EXTERIOR <br />GRADE SHEATHING <br />EXTERIOR MATERIALS VARY, RE: <br />ELEVATIONS <br />FIBER CEMENT SOFFIT BD. <br />PREFINISHED METAL <br />RAKE FLASHING <br />ICE AND WATER SHIELD, <br />EXTEND PAST PLANE OF WALL <br />PER LOCAL BUILDING CODES <br />TOP LAYER OF ROOFING <br />UNDERLAYMENT <br />1" FIBER CEMENT <br />BOARD FASCIA, <br />PAINTED <br />(2) LAYERS WEATHER RESISTANT BARRIER ON <br />EXTERIOR GRADE SHEATHING, LAP INTO WEEP <br />SCREED <br />P.T. WOOD SILL INSTALLED OVER CONTINUOUS BEAD OF <br />SEALANT ALONG EXTERIOR EDGE OF CONCRETE AT SLAB <br />ON GRADE INSTALLATIONS <br />STUCCO SYSTEM ON LATH. INSTALL PER MFR. <br />RECOMMENDATIONS <br />GRADE WHERE OCCURS <br />WEEP SCREED W/ 3-1/2" MIN. VERTICAL LEG <br />EDGE OF FOUNDATION <br />SELF ADHERED FLASHING, EXTEND UP WALL 12" MIN. <br />CONTINUOUS SILL SEALER LOCATED <br />TOWARD OUTER EDGE <br />8" <br /> <br />M <br />I <br />N <br />. <br />6" <br /> <br />M <br />I <br />N <br />. <br />SELF ADHERED WATERPROOF WRB SYSTEMS <br />TAPE <br />6" = 1'-0"5HORIZ. JNT. @ CEM. PLASTER <br />6" = 1'-0"6HORIZ. JNT. WEEP @CEM. PLASTER2" = 1'9WOOD -1-HR WALL -STUCCO -EXTERIOR <br />2" = 1'8WOOD NON-RATED -INTERIOR PARTITION <br />3" = 1'-0"3WOOD -STUCCO -WALL TO CONCRETE AT FOUNDATION <br />3" = 1'-0"1WOOD -STUCCO -OUTSIDE CORNER TYP. <br />3" = 1'-0"2WOOD -STUCCO -ASSEMBLY <br />1 1/2" = 1'-0"4DUCT IN SOFFIT DETAIL1 1/2" = 1'-0"7WOOD -ASPHALT SHINGLE -VENT THROUGH ROOF <br />3" = 1'-0"11WOOD -ASPHALT SHINGLE -RAKE <br />3" = 1'-0"12WOOD -STUCCO -WALL AT GARAGE NO INSULATION <br />101-HR FIRE RESISTANT EAVE PROJECTION <br />PROJECT CONTACT <br />OWNERSHIP <br />IT IS THE SUBCONTRACTORS RESPONSIBILITY PRIOR TO OR DURING <br />CONSTRUCTION TO NOTIFY THE DESIGNERS OR JOB FOREMAN IN WRITING <br />OR IN VERBAL OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS <br />AND SPECIFICATIONS OF WHICH A SUBCONTRACTOR THOROUGHLY <br />KNOWLEDGEABLE WITH THE BUILDING CODES AND METHODS OF <br />CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN OR VERBAL <br />INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS <br />SHALL BE RECEIVED FROM THE DESIGNERS OR JOB FOREMAN PRIOR TO <br />THE SUBCONTRACTORS BEFORE PROCEEDING WITH THE WORK. THE <br />OWNERS WILL NOT BE RESPONSIBLE FOR ANY DEFECTS IN <br />CONSTRUCTION IF THESE PROCEDURES ARE NOT BEING FOLLOWED. <br />DESCRIPTIONDATEDELTA <br />A-07 <br />WALL AND ROOF <br />DETAILS <br />NE <br />W <br /> <br />D <br />E <br />T <br />A <br />C <br />H <br />E <br />D <br /> <br />A <br />D <br />U <br />13 <br />1 <br />3 <br /> <br /> <br />E <br />N <br />G <br />L <br />I <br />S <br />H <br /> <br />S <br />T <br /> <br />U <br />N <br />I <br />T <br /> <br />2 <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />EX <br />I <br />S <br />T <br />I <br />N <br />G <br /> <br />M <br />A <br />I <br />N <br /> <br />H <br />O <br />U <br />S <br />E <br />13 <br />1 <br />3 <br /> <br /> <br />E <br />N <br />G <br />L <br />I <br />S <br />H <br /> <br />S <br />T <br />. <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />DETACHED ADU: <br />2 BEDROOMS, <br />2 BATHROOMS, <br />LIVING, KITCHEN, <br />DINING, AND <br />LAUNDRY <br /> 01/31/2024 PLAN CHECK SUBMITTAL <br />LOAN PHAM <br />17021 BOLERO LN <br />HUNTINGTON BEACH, CA 92649 <br />PHONE: 714-614-6344 <br />EMAIL: LOANPHAM8888@YAHOO.COM <br />KHANH DAO <br />10448 SALINAS RIVER CIR <br />FOUNTAIN VALLEY, CA 92708 <br />PHONE: (714) 390-5154 <br />1313 N English St <br />8/28/2024