Laserfiche WebLink
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) <br />Member Reaction (lbs)1055 @ 15' 7/16"5206 (3.50")Passed (20%)--1.0 D + 1.0 Lr (Alt Spans) <br />Shear (lbs)852 @ 14' 3 7/8"3806 Passed (22%)1.25 1.0 D + 1.0 Lr (Alt Spans) <br />Moment (Ft-lbs)2518 @ 9' 7 5/16"3737 Passed (67%)1.25 1.0 D + 1.0 Lr (Alt Spans) <br />Live Load Defl. (in)0.230 @ 8' 10 13/16"0.656 Passed (L/684)--1.0 D + 1.0 Lr (Alt Spans) <br />Total Load Defl. (in)0.428 @ 8' 10 3/4"0.875 Passed (L/368)--1.0 D + 1.0 Lr (Alt Spans) <br />System : Roof <br />Member Type : Flush Beam <br />Building Use : Residential <br />Building Code : IBC 2021 <br />Design Methodology : ASD <br />Member Pitch : 2.83/12 <br />•Deflection criteria: LL (L/240) and TL (L/180). <br />•Overhang deflection criteria: LL (2L/240) and TL (2L/180). <br />•Allowed moment does not reflect the adjustment for the beam stability factor. <br />•Applicable calculations are based on NDS. <br />• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. <br />Bearing Length Loads to Supports (lbs) <br />Supports Total Available Required Dead Roof Live Factored Accessories <br />1 - Beveled Plate - SPF 3.50"3.50"1.50"313 329 642 Blocking <br />2 - Beveled Plate - SPF 3.50"3.50"1.50"482 573 1055 Blocking <br />•Maximum allowable bracing intervals based on applied load. <br />Lateral Bracing Bracing Intervals Comments <br />Top Edge (Lu)15' 7" o/c <br />Bottom Edge (Lu)15' 7" o/c <br />Dead Roof Live <br />Vertical Loads Location (Side)Tributary Width (0.90)(non-snow: 1.25)Comments <br />0 - Self Weight (PLF)0 to 15' 2 7/16"N/A 6.4 -- <br />1 - Tapered (PLF)0 to 2' 1 7/16"N/A 0.0 to 32.6 0.0 to 42.4 Generated from <br />Roof Geometry <br />2 - Tapered (PLF)2' 1 7/16" to 15' 2 7/16"N/A 0.0 to 98.0 0.0 to 130.8 Generated from <br />Roof Geometry <br />Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties <br />related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is <br />responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at <br />Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 <br />and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to <br />www.weyerhaeuser.com/woodproducts/document-library. <br />The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator <br />Weyerhaeuser Notes <br />All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.Member Length : 15' 9 1/8" <br />MEMBER REPORT PASSED <br />Level, BM1 - Hip Beam <br />1 piece(s) 4 x 8 DF No.2 <br />ForteWEB Software Operator Job Notes 1/28/2024 5:16:31 AM UTC <br />Trang Ho <br />LT Designs <br />(714) 213-1608 <br />onetrang10@gmail.com <br />ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1 <br />File Name: 1313 English St <br />Page 5 / 8 <br />6 <br />1313 N English St <br />8/28/2024