Laserfiche WebLink
Date :5/10/2023 <br />Job Code: ALBINO GONZALEZ <br />5 of 6 <br />All Roofs 0.9D + 1.0W (Up z2) : 139 lb-ft <548 lb-ft OK <br />Attachment Check (ASD): <br />All Roofs 1.0D + 0.6W : 146 lbs <907 lbs OK <br />All Roofs 1.0D + 0.75*[1.0S + 0.6W] : 116 lbs <907 lbs OK <br />All Roofs 1.0D + 1.0S : 28 lbs <907 lbs OK <br />All Roofs 0.6D + 0.6W (Up z1) : 225 lbs <512.5 lbs OK <br />All Roofs 0.6D + 0.6W (Up z2) : 298 lbs <512.5 lbs OK <br />Lag Screw Uplift Check (ASD): <br />All Roofs Lag Screw Withdrawl Value = 266 lbs 5/16 Dia. <br />All Roofs Lag Screw Penetration = 2.5 <br />All Roofs 0.6D + 0.6W (Up z1) : 225 lbs <665 lbs OK <br />All Roofs 0.6D + 0.6W (Up z2) : 298 lbs <665 lbs OK <br />Framing Check (ASD): <br />All Roofs uni 1.0D + 0.6W : 1473 lb-ft <2176 lb-ft OK <br />All Roofs uni 1.0D + 0.75*[1.0S + 0.6W] : 1338 lb-ft <2176 lb-ft OK <br />All Roofs uni 1.0D + 1.0S : 933 lb-ft <1564 lb-ft OK <br />All Roofs uni 0.6D + 0.6W (Up z1) : 548 lb-ft <2176 lb-ft OK <br />Framing Deflection Check (Service Level): <br />All Roofs uni D + L : 0.744 in.<1.00 in.OK <br />All Roofs uni W Up : 0.412 in.<0.75 in.OK <br />All Roofs uni W Down : 0.201 in.<0.75 in.OK <br />All Roofs uni S : 0.000 in.<0.75 in.OK <br />Seismic Check: <br />Stucco 10.0 psf <br />2x4 Studs @ 16"2.0 psf <br />Gypsum 3.0 psf <br />Misc. (Insulation, etc.)2.0 psf <br />51 Rio Roble, San Jose, CA 95134 | 1-408-240-5500 <br />1314 S Shawnee <br />Dr09/05/23