My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1316 N Sycamore St, Unit 100 & 101 - Plan
PBA
>
Building
>
ProjectDox
>
S
>
Sycamore St
>
1316 N Sycamore St Unit# 100
>
1316 N Sycamore St, Unit 100 & 101 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 11:56:55 AM
Creation date
6/1/2025 11:56:38 AM
Metadata
Fields
Template:
Plan
Permit Number
101115529
101115530
Full Address
1316 N Sycamore St Unit# 100
1316 N Sycamore St Unit# 101
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
75
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
1316 S Sycamore St <br />Santa Ana, CA 92701 <br />Sheet <br />T-24 <br />CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E <br />Project Name:1316 S SYCAMORE ST UNIT 101 Calculation Date/Time:2023-09-16T02:10:13-07:00 (Page 1 of 10) <br />Calculation Description:Title 24 Analysis Input File Name:1316 S SYCAMORE ST UNIT 101.ribd22x <br />Registration Number:Registration Date/Time: HERS Provider: <br />CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 <br />Schema Version: rev 20220901 <br />Report Generated: 2023-09-16 02:10:37 <br />GENERAL INFORMATION <br />01 Project Name 1316 S SYCAMORE ST UNIT 101 <br />02 Run Title Title 24 Analysis <br />03 Project Location 1316 S SYCAMORE ST UNIT 101 <br />04 City SANTA ANA 05 Standards Version 2022 <br />06 Zip code 92701 07 Software Version EnergyPro 9.1 <br />08 Climate Zone 8 09 Front Orientation (deg/ Cardinal)90 <br />10 Building Type Single family 11 Number of Dwelling Units 1 <br />12 Project Scope Newly Constructed 13 Number of Bedrooms 3 <br />14 Addition Cond. Floor Area (ft2)0 15 Number of Stories 1 <br />16 Existing Cond. Floor Area (ft2)n/a 17 Fenestration Average U-factor 0.3 <br />18 Total Cond. Floor Area (ft2)427 19 Glazing Percentage (%)19.90% <br />20 ADU Bedroom Count n/a <br />COMPLIANCE RESULTS <br />01 Building Complies with Computer Performance <br />02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. <br />03 This building incorporates one or more Special Features shown below <br />423-P010169194A-000-000-0000000-0000 09/16/2023 02:12 CHEERS <br />NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, <br />and cannot guarantee, the accuracy or completeness of the information contained in this document. <br />CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E <br />Project Name:1316 S SYCAMORE ST UNIT 101 Calculation Date/Time:2023-09-16T02:10:13-07:00 (Page 2 of 10) <br />Calculation Description:Title 24 Analysis Input File Name:1316 S SYCAMORE ST UNIT 101.ribd22x <br />Registration Number:Registration Date/Time: HERS Provider: <br />CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 <br />Schema Version: rev 20220901 <br />Report Generated: 2023-09-16 02:10:37 <br />ENERGY DESIGN RATINGS <br />Energy Design Ratings Compliance Margins <br />Source Energy <br />(EDR1) <br />Efficiency1 EDR <br />(EDR2efficiency) <br />Total2 EDR <br />(EDR2total) <br />Source Energy <br />(EDR1) <br />Efficiency1 EDR <br />(EDR2efficiency) <br />Total2 EDR <br />(EDR2total) <br />Standard Design 43.1 45.7 32.3 <br />Proposed Design 40.5 35.3 27.2 2.6 10.4 5.1 <br />RESULT3: PASS <br />1Efficiency EDR includes improvements like a better building envelope and more efficient equipment <br />2Total EDR includes efficiency and demand response measures such as photovoltaic (PV) system and batteries <br />3Building complies when source energy, efficiency and total compliance margins are greater than or equal to zero and unmet load hour limits are not exceeded <br />•Standard Design PV Capacity: 2.36 kWdc <br />•PV System resized to 2.36 kWdc (a factor of 2.362) to achieve 'Standard Design PV' PV scaling <br />423-P010169194A-000-000-0000000-0000 09/16/2023 02:12 CHEERS <br />NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, <br />and cannot guarantee, the accuracy or completeness of the information contained in this document. <br />CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E <br />Project Name:1316 S SYCAMORE ST UNIT 101 Calculation Date/Time:2023-09-16T02:10:13-07:00 (Page 3 of 10) <br />Calculation Description:Title 24 Analysis Input File Name:1316 S SYCAMORE ST UNIT 101.ribd22x <br />Registration Number:Registration Date/Time: HERS Provider: <br />CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 <br />Schema Version: rev 20220901 <br />Report Generated: 2023-09-16 02:10:37 <br />ENERGY USE SUMMARY <br />Energy Use Standard Design Source <br />Energy (EDR1) (kBtu/ft2 -yr) <br />Standard Design TDV Energy <br />(EDR2) (kTDV/ft2 -yr) <br />Proposed Design Source <br />Energy (EDR1) (kBtu/ft2 -yr) <br />Proposed Design TDV Energy <br />(EDR2) (kTDV/ft2 -yr) <br />Compliance <br />Margin (EDR1) <br />Compliance <br />Margin (EDR2) <br />Space Heating 0 0 0.82 6.26 -0.82 -6.26 <br />Space Cooling 3.01 59.61 1.5 37.96 1.51 21.65 <br />IAQ Ventilation 0.78 8.16 0.78 8.16 0 0 <br />Water Heating 4.26 46.15 3.34 35.66 0.92 10.49 <br />Self <br />Utilization/Flexibility <br />Credit <br />0 0 <br />Efficiency Compliance <br />Total 8.05 113.92 6.44 88.04 1.61 25.88 <br />Photovoltaics -6.06 -182.95 -6.06 -180.84 <br />Battery 0 0 <br />Flexibility <br />Indoor Lighting 1.27 11.95 1.27 11.95 <br />Appl. & Cooking 13.35 86.77 13.16 84.98 <br />Plug Loads 12.82 130.56 12.82 130.56 <br />Outdoor Lighting 0.24 2.05 0.24 2.05 <br />TOTAL COMPLIANCE 29.67 162.3 27.87 136.74 <br />423-P010169194A-000-000-0000000-0000 09/16/2023 02:12 CHEERS <br />NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, <br />and cannot guarantee, the accuracy or completeness of the information contained in this document. <br />CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E <br />Project Name:1316 S SYCAMORE ST UNIT 101 Calculation Date/Time:2023-09-16T02:10:13-07:00 (Page 4 of 10) <br />Calculation Description:Title 24 Analysis Input File Name:1316 S SYCAMORE ST UNIT 101.ribd22x <br />Registration Number:Registration Date/Time: HERS Provider: <br />CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 <br />Schema Version: rev 20220901 <br />Report Generated: 2023-09-16 02:10:37 <br />ENERGY USE INTENSITY <br />Standard Design (kBtu/ft2 - yr )Proposed Design (kBtu/ft2 - yr )Compliance Margin (kBtu/ft2 - yr )Margin Percentage <br />Gross EUI1 47.15 43.29 3.86 8.19 <br />Net EUI2 16.3 12.44 3.86 23.68 <br />Notes <br /> 1. Gross EUI is Energy Use Total (not including PV) / Total Building Area. <br /> 2. Net EUI is Energy Use Total (including PV) / Total Building Area. <br />REQUIRED PV SYSTEMS <br />01 02 03 04 05 06 07 08 09 10 11 12 <br />DC System Size <br />(kWdc)Exception Module Type Array Type Power Electronics CFI Azimuth <br />(deg) <br />Tilt <br />Input <br />Array Angle <br />(deg) <br />Tilt: (x in <br />12) <br />Inverter Eff. <br />(%) <br />Annual <br />Solar Access <br />(%) <br />2.36 NA Standard (14-17%)Fixed none true 150-270 n/a n/a <=7:12 96 98 <br />REQUIRED SPECIAL FEATURES <br />The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. <br />•Insulation below roof deck <br />•Variable capacity heat pump compliance option (verification details from VCHP Staff report, Appendix B, and RA3) <br />•Northwest Energy Efficiency Alliance (NEEA) rated heat pump water heater; specific brand/model, or equivalent, must be installed <br />423-P010169194A-000-000-0000000-0000 09/16/2023 02:12 CHEERS <br />NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, <br />and cannot guarantee, the accuracy or completeness of the information contained in this document. <br />CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E <br />Project Name:1316 S SYCAMORE ST UNIT 101 Calculation Date/Time:2023-09-16T02:10:13-07:00 (Page 5 of 10) <br />Calculation Description:Title 24 Analysis Input File Name:1316 S SYCAMORE ST UNIT 101.ribd22x <br />Registration Number:Registration Date/Time: HERS Provider: <br />CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 <br />Schema Version: rev 20220901 <br />Report Generated: 2023-09-16 02:10:37 <br />HERS FEATURE SUMMARY <br />The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional <br />detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry <br />•Quality insulation installation (QII) <br />•Indoor air quality ventilation <br />•Kitchen range hood <br />•Verified EER/EER2 <br />•Verified SEER/SEER2 <br />•Verified Refrigerant Charge <br />•Airflow in habitable rooms (SC3.1.4.1.7) <br />•Verified HSPF2 <br />•Verified heat pump rated heating capacity <br />•Wall-mounted thermostat in zones greater than 150 ft2 (SC3.4.5) <br />•Ductless indoor units located entirely in conditioned space (SC3.1.4.1.8) <br />BUILDING - FEATURES INFORMATION <br />01 02 03 04 05 06 07 <br />Project Name Conditioned Floor Area (ft2)Number of Dwelling <br />Units Number of Bedrooms Number of Zones Number of Ventilation <br />Cooling Systems <br />Number of Water <br />Heating Systems <br />1316 S SYCAMORE ST UNIT 101 427 1 3 1 0 1 <br />ZONE INFORMATION <br />01 02 03 04 05 06 07 <br />Zone Name Zone Type HVAC System Name Zone Floor Area (ft2)Avg. Ceiling Height Water Heating System 1 Status <br />UNIT 101 Conditioned HVAC1 427 9 DHW Sys 1 New <br />OPAQUE SURFACES <br />01 02 03 04 05 06 07 08 <br />Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door <br />Area (ft2)Tilt (deg) <br />FRONT WALL UNIT 101 R-15 Wall 90 Front 135 36 90 <br />RIGHT WALL UNIT 101 R-15 Wall 0 Right 252 32 90 <br />REAR WALL UNIT 101 R-15 Wall 270 Back 135 37 90 <br />423-P010169194A-000-000-0000000-0000 09/16/2023 02:12 CHEERS <br />NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, <br />and cannot guarantee, the accuracy or completeness of the information contained in this document. <br />CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E <br />Project Name:1316 S SYCAMORE ST UNIT 101 Calculation Date/Time:2023-09-16T02:10:13-07:00 (Page 6 of 10) <br />Calculation Description:Title 24 Analysis Input File Name:1316 S SYCAMORE ST UNIT 101.ribd22x <br />Registration Number:Registration Date/Time: HERS Provider: <br />CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 <br />Schema Version: rev 20220901 <br />Report Generated: 2023-09-16 02:10:37 <br />OPAQUE SURFACES <br />01 02 03 04 05 06 07 08 <br />Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door <br />Area (ft2)Tilt (deg) <br />Interior Surface UNIT 101>>UNIT 101 R-15 Wall1 n/a n/a 252 0 n/a <br />Roof UNIT 101 R-38 HP Attic n/a n/a 427 n/a n/a <br />ATTIC <br />01 02 03 04 05 06 07 08 <br />Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof <br />Attic UNIT 101 Attic RoofUNIT 101 Ventilated 4 0.1 0.85 Yes No <br />FENESTRATION / GLAZING <br />01 02 03 04 05 06 07 08 09 10 11 12 13 14 <br />Name Type Surface Orientation Azimuth Width <br />(ft) <br />Height <br />(ft)Mult.Area <br />(ft2)U-factor U-factor <br />Source SHGC SHGC Source Exterior Shading <br />D Window FRONT WALL Front 90 1 16 0.3 NFRC 0.23 NFRC Bug Screen <br />D 2 Window RIGHT WALL Right 0 1 16 0.3 NFRC 0.23 NFRC Bug Screen <br />D 3 Window RIGHT WALL Right 0 1 16 0.3 NFRC 0.23 NFRC Bug Screen <br />C Window REAR WALL Back 270 1 33 0.3 NFRC 0.23 NFRC Bug Screen <br />E Window REAR WALL Back 270 1 4 0.3 NFRC 0.23 NFRC Bug Screen <br />OPAQUE DOORS <br />01 02 03 04 <br />Name Side of Building Area (ft2)U-factor <br />A FRONT WALL 20 0.2 <br />423-P010169194A-000-000-0000000-0000 09/16/2023 02:12 CHEERS <br />NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, <br />and cannot guarantee, the accuracy or completeness of the information contained in this document. <br />1316 N Sycamore St, Unit 100 <br />& 101 - 101115529-30 <br />11/8/2023
The URL can be used to link to this page
Your browser does not support the video tag.