Laserfiche WebLink
1 <br />27 <br />' <br />- <br />4 <br />" <br />54'-9" <br />1 <br />2 <br />7 <br />' <br />- <br />4 <br />" <br />54'-9" <br />1 <br />2 <br />' <br />- <br />1 <br />1 <br />" <br />13'-0" <br />60 <br />' <br />- <br />1 <br />1 <br />" <br />2'-2" <br />5'-0" <br />5'-0" <br />MA <br />R <br />I <br />A <br /> <br />M <br />E <br />R <br />L <br />O <br />S <br />1 <br />1 <br />0 <br />1 <br /> <br />W <br /> <br />6 <br />T <br />H <br /> <br />S <br />T <br />, <br />, <br /> <br /> S <br />A <br />N <br />T <br />A <br />AN <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />PH <br />O <br />N <br />E <br />: <br /> <br />( <br />7 <br />1 <br />4 <br />) <br />- <br />4 <br />6 <br />8 <br />- <br />8 <br />1 <br />0 <br />3 <br />AP <br />N <br />: <br /> <br />4 <br />0 <br />5 <br />0 <br />8 <br />2 <br />1 <br />4 <br />AM <br />E <br />R <br />I <br />C <br />A <br />N <br /> <br />S <br />O <br />L <br />A <br />R <br /> <br />A <br />D <br />V <br />A <br />N <br />T <br />A <br />G <br />E <br />1 <br />3 <br />3 <br />4 <br />8 <br /> <br />M <br />O <br />N <br />T <br />E <br /> <br />V <br />I <br />S <br />T <br />A <br /> <br />A <br />V <br />E <br />CH <br />I <br />N <br />O <br />, <br /> <br />C <br />A <br /> <br />9 <br />1 <br />7 <br />1 <br />0 <br />(8 <br />7 <br />7 <br />) <br /> <br />7 <br />6 <br />5 <br />- <br />2 <br />3 <br />8 <br />8 <br />CS <br />L <br />B <br />- <br />C <br />1 <br />0 <br /> <br /># <br />1 <br />0 <br />0 <br />9 <br />5 <br />6 <br />5 <br />BO <br />B <br />B <br />Y <br /> <br />D <br /> <br />H <br />A <br />R <br />R <br />I <br />S <br />PH <br />O <br />T <br />O <br />V <br />O <br />L <br />T <br />A <br />I <br />C <br /> <br /> S <br />Y <br />S <br />T <br />E <br />M <br /> <br />P <br />L <br />A <br />N <br /> 5 <br />. <br />6 <br />0 <br />0 <br /> <br />k <br />W <br /> <br />D <br />C <br />, <br /> <br />5 <br />. <br />0 <br />4 <br />9 <br /> <br />k <br />w <br /> <br />A <br />C <br />DA <br />T <br />E <br />: <br /> <br />0 <br />8 <br />/ <br />2 <br />8 <br />/ <br />2 <br />0 <br />2 <br />2 <br /> <br />P <br />L <br />O <br />T <br />T <br />E <br />D <br />: <br /> <br />8 <br />/ <br />2 <br />3 <br />/ <br />2 <br />0 <br />2 <br />2 <br />DE <br />S <br />I <br />G <br />N <br />E <br />R <br />: <br /> <br />N <br />. <br />Y <br />. <br /> <br />A <br />H <br />J <br />: <br /> <br />R <br />I <br />V <br />E <br />R <br />S <br />I <br />D <br />E <br /> <br />C <br />O <br />U <br />N <br />T <br />Y <br />SOLAR PHOTOVOLTAIC SYSTEM NOTES: <br />1. ALL MATERIALS, EQUIPMENT, INSTALLATION AND WORK <br /> SHALL COMPLY WITH THE FOLLOWING APPLICABLE CODES: <br /> 2022 CA BUILDING CODE, PART 2 <br /> 2022 CA RESIDENTIAL CODE PART, 2.5 <br /> 2022 CA MECHANICAL CODE, PART 4 <br /> 2022 CA ELECTRICAL CODE, PART 3 <br /> 2022 CA PLUMBING CODE, PART 5 <br /> 2022 CA EXISTING BUILDING CODE, PART 10 <br /> 2022 CA GREEN BUILDING STANDARDS CODE, PART 11 <br /> 2022 CA REFERENCE STANDARDS CODE, PART 12 <br /> 2022 CA FIRE CODE <br />2. EXISTING PLUMBING VENTS, SKYLIGHTS, EXHAUST <br /> OUTLETS, VENTILATION'S INTAKE AIR OPENINGS SHALL NOT <br /> BE COVERED BY THE SOLAR PHOTOVOLTAIC SYSTEM. <br />3. ALL EQUIPMENT SHALL BE LISTED AND LABELED BY A <br /> RECOGNIZED ELECTRICAL TESTING LABORATORY AND <br /> INSTALLED PER THE LISTING REQUIREMENTS AND THE <br /> MANUFACTURER'S INSTRUCTIONS. [NEC 690.4(D)] <br />4. ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED, <br /> INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND <br /> SWITCHES. <br />5. PAINT PV CONDUIT TO MATCH THE DWELLING EXTERIOR. <br />6. CONTACT THE SERVICING UTILITY BEFORE POWERING ON <br /> THE PHOTOVOLTAIC SYSTEM. <br />SCALE: NTS <br />3 VICINITY MAP <br />PV 1 <br />INDEX OF SHEETS RM <br />PV1 <br />PV2 <br />PV3 <br />PV4 <br />PV5 <br />PV6 <br />TITLE SHEET - SITE PLAN & NOTES <br />ROOF PLAN <br />STRUCTURAL DETAILS <br />SINGLE LINE DIAGRAM (S.L.D.) <br />SIGNAGE <br />INSTALLER OPTIMIZER/ <br />MICROINVERTER MAP <br />COMP SHINGLE <br />SITE INFORMATION <br />1 STORY ROOF: <br />SCOPE OF WORK <br />(14) SEG SOLAR SEG-400-BMD-HIV[400W] <br />PURE PV MODULES <br />(14) ENPHASE ENERGY <br />IQ8PLUS-72-2-US[240V] <br />[1] AC COMBINER PANEL <br />(E) 125A MAIN SERVICE PANEL <br />DESIGN CRITERIA <br />SINGLE FAMILY RESIDENCE <br />OCCUPANCY: R-3, U <br />CONSTRUCTION TYPE: VB <br />WIND SPEED: 110 MPH <br />EXPOSURE CATEGORY: C <br />MIN STANDOFF HEIGHT OF: 6" <br />CONDUIT:3/4" <br />FIRE SPRINKLER: NO <br />LAT & LONG. : 33.7498692, -117.8817128 <br />SNOW LOAD: 0 <br />SYSTEM FIRE RATING CLASS A WHEN <br />TYPE I OR II PV MODULE USED PER <br />R902.3 OR R904.4 <br />ROOF AREA: 1983 SQ.FT. <br />PV ARRAY AREA: 294.2 SQ.FT. <br />SCALE: 1/16" <br />1 PLOT PLAN <br />PV 1 <br />TITLE SHEET- <br />SITE PLAN & <br />NOTES <br />PV1 <br />(N) ROOF MOUNTED <br />PV SOLAR MODULES <br />JB <br />FMC USED FOR OUTDOOR CONDUIT RUNS,EMT <br />USED FOR EXTERNAL <br />CONDUIT RUNS <br />(E) DRIVEWAY <br />PROPERTY LINE <br />PROPERTY LINE <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br />(E) MAIN RESIDENCE <br />MS <br />P <br />MT <br />R <br />AC <br />D <br />IQ <br />C <br />MAIN SERVICE PANEL & METER <br />(N) 30A AC DISCONNECT VISIBLE <br />BLADE,LOCKABLE TYPE <br />(N) IQ AC COMBINER PANEL <br />(E) FENCE <br />SU <br />B SUB PANEL <br />W 6TH ST, <br />FRONT OF HOUSE <br />N <br />S <br />H <br />E <br />L <br />T <br />O <br />N <br /> <br />ST <br />. <br />NOTES <br />EXTERIOR CONDUIT MAY NOT BE INSTALLED WITHIN ANY REQUIRED <br />MUST BE 5'0" MAXIMUM LENGTH ON EXTERIOR OR ALL IN ATTIC <br />PATHWAY TO THE RIDGE AND SHALL NOT BE INSTALLED WITHIN ANY <br />REQUIRED SETBACK AT THE RIDGE NO INTERIOR CONDUIT SHALL BE <br />INSTALLED WITHIN ANY REQUIRED SETBACK AT THE RIDGE. <br />SHED <br />This item has been digitally <br />signed and sealed on <br />12/20/2022 <br />STRUCTURAL ONLYBLDG# 101114273 ISS. 3/16/2023 <br />ELEC# 20179021 ISS. 3/21/2023 <br /> <br />The scope of the plans is for the installation of the <br />solar photovoltaic system only and the approval is <br />subject to compliance with all applicable city and <br />state codes and regulations regarding construction. <br /> The approval of the plans does not constitute any <br />certification of the accuracy, completeness, or <br />building permit status of the existing buildings and <br />structures as shown. <br />1101 W 6th St <br />03/21/23