Laserfiche WebLink
MOUNTING DETAILS <br />S-1.0 <br />CUSTOMER INFORMATION <br />NAME&ADDRESS: <br />33°43'51.28"N 117°51'38.58"W <br />APN:014-203-51 <br />AHJ:CA-CITY OF SANTA ANA <br />UTILITY:SCE <br />SYSTEM INFORMATION <br />DESIGNER/CHECKED BY: <br />MV/MR <br />PROJECT NUMBER:LARS-007802 <br />SCALE:AS NOTED PAPER SIZE:17"x11" <br />MONICA FAJARDO <br />1276 S HICKORY ST, SANTA ANA, CA 92707. <br />ENGINEER OF RECORD <br />DATE:10/29/22 REV:A <br />CONTRACTOR INFORMATION <br />DC SYSTEM SIZE: 5850W <br />AC SYSTEM SIZE: 5000W <br />CEC AC SYSTEM SIZE: 5464W <br />MODULES: <br />(15)CANADIAN SOLAR CS3N-390MS <br />INVERTER: <br />(1)SOLAREDGE TECHNOLOGIES <br />SE5000H-US(240V,1PH) <br />OPTIMIZER: <br />(15)S440 SOLAREDGE OPTIMIZER <br />HARNESS BUILDING SOLUTIONS, <br />439 E,HARRISON ST,UNIT E, <br />CORONA, CA 92879. <br />TEL:951-298-9007 <br />LIC:#9B@1072291 <br />PV-3.0 <br />B MOUNTING DETAILS <br />SCALE: 1/8" = 1'-0" <br />UPLIFT CALCULATIONS <br />UPLIFT 9860.4 LBS <br />PULL OUT STRENGTH 14760 LBS <br />POINT LOADING 31 LBS <br />MODULES DATA <br />CANADIAN SOLAR CS3N-390MS <br />MODULE DIMS 76.4"x41.3"x1.38" <br />LAG SCREWS 5/16"x3":2.5"MIN EMBEDMENT <br />AERIAL VIEW <br />SITE INFORMATION <br />SR.NO AZIMUTH PITCH NO. OF <br />MODULES <br />ARRAY AREA <br />(SQ. FT.)ROOF TYPE ATTACHMENT ROOF <br />EXPOSURE FRAME TYPE FRAME <br />SIZE <br />FRAME <br />SPACING <br />MAX RAIL <br />SPAN <br />OVER <br />HANG <br />MP-01 180° 10° 15 328.7 COMPOSITION <br />SHINGLE FLASH FOOT ATTIC RAFTERS 2 X 6 1'-4" 5'-4" 2'-0" <br />ARRAY MP-01 <br />ALUMINIUM RAILS <br />2 X 6 RAFTERS@ 1'-4" SPACING <br />MINIMUM FIRE ACCESS PATHWAYS PER CFC 2019 <br />RIDGE TO ARRAY: 1'-6" <br />EAVE TO ARRAY : 3'-0" <br />HIP/VALLEY W/ ADJACENT ARRAY: 1'-6" <br />EACH SIDE HIP/VALLEY W/O ADJACENT ARRAY: 0'-0" <br />NOTE: INSTALLER TO VERIFY RAFTER SIZE, SPACING AND SLOPED <br />SPANS, AND NOTIFY ANY DISCREPANCIES BEFORE PROCEEDING. <br />FIRE SETBACK <br />DEAD LOAD CALCULATIONS <br />BOM QUANTITY LBS/UNIT TOTAL <br />WEIGHT (LBS) <br />MODULES 15 49.6 744.00 <br />MID-CLAMP 26 0.050 1.30 <br />END-CLAMP 8 0.050 0.40 <br />RAIL LENGTH 106 0.680 72.08 <br />SPLICE BAR 6 0.360 2.16 <br />FLASH FOOT 24 1.35 32.40 <br />TOTAL WEIGHT OF THE SYSTEM (LBS)852.34 <br />TOTAL ARRAY AREA ON THE ROOF (SQ. FT.)328.68 <br />WEIGHT PER SQ. FT.(LBS)2.59 <br />WEIGHT PER PENETRATION (LBS)35.51 <br />3' <br />1' <br />- <br />6 <br />" <br />5'-4" <br />This item has been digitally signed <br />and sealed on Nov 11, 2022 <br />1276 S Hickory St <br />02/10/23