Laserfiche WebLink
MOUNTING DETAILS <br />PV-3.0 <br />CUSTOMER INFORMATION <br />NAME&ADDRESS: <br />33°43'54.17"N 117°52'53.71"W <br />APN:013-024-23 <br />AHJ:CA-CITY OF SANTA ANA <br />UTILITY:SCE <br />SYSTEM INFORMATION <br />DESIGNER/CHECKED BY: <br />SB/MR <br />PROJECT NUMBER:GOSG-007806 <br />SCALE:AS NOTED PAPER SIZE:17"x11" <br />EVERARDO ALDAPA <br />1225 S ROSEWOOD AVE, SANTA ANA, CA 92707. <br />ENGINEER OF RECORD <br />DATE:02/16/2023 REV:A <br />DC SYSTEM SIZE: 8800W <br />AC SYSTEM SIZE: 6380W <br />CEC AC SYSTEM SIZE: 8013W <br />MODULES: <br />(22)URECO FBM400MFG-BB <br />INVERTER: <br />(22)ENPHASE IQ8PLUS-72-2-US(240V,1PH) <br />BRANCH DETAILS: <br />2 BRANCH OF 11 MICRO INVERTERS (11 MODULES) <br />CONTRACTOR INFORMATION <br />18271 MCDURMOTT W SUITE E, IRVINE, <br />CA 92614. <br />TEL.NO: 949-309-2453 <br />LIC:#B/C10 - 1037212 <br />PV-3.0 <br />B MOUNTING DETAILS <br />SCALE: 3/32" = 1'-0" <br />UPLIFT CALCULATIONS <br />UPLIFT 13868.7 LBS <br />PULL OUT STRENGTH 30750 LBS <br />POINT LOADING 21 LBS <br />MODULES DATA <br />URECO FBM400MFG-BB <br />MODULE DIMS 67.83"x44.61"x1.38" <br />LAG SCREWS 5/16"x3":2.5"MIN EMBEDMENT <br />AERIAL VIEW <br />SITE INFORMATION <br />SR.NO AZIMUTH PITCH NO. OF <br />MODULES <br />ARRAY AREA <br />(SQ. FT.)ROOF TYPE ATTACHMENT ROOF <br />EXPOSURE FRAME TYPE FRAME <br />SIZE <br />FRAME <br />SPACING <br />MAX RAIL <br />SPAN <br />OVER <br />HANG <br />MP-01 270° 20° 7 147.1 COMPOSITION <br />SHINGLE FLASH FOOT ATTIC RAFTERS 2 X 4 2'-0"6'-0" 2'-0" <br />MP-02 180° 20° 4 84.1 COMPOSITION <br />SHINGLE FLASHFOOT ATTIC RAFTERS 2 X 4 2'-0"6'-0" 2'-0" <br />MP-03 180° 20° 7 147.1 COMPOSITION <br />SHINGLE FLASHFOOT ATTIC RAFTERS 2 X 4 2'-0"6'-0" 2'-0" <br />MP-04 90° 20° 4 84.1 COMPOSITION <br />SHINGLE FLASHFOOT ATTIC RAFTERS 2 X 4 2'-0"6'-0" 2'-0" <br />MINIMUM FIRE ACCESS PATHWAYS PER CFC 2022 <br />RIDGE TO ARRAY: 3'-0" <br />EAVE TO ARRAY : 3'-0" <br />HIP/VALLEY W/ ADJACENT ARRAY: 1'-6" <br />EACH SIDE HIP/VALLEY W/O ADJACENT ARRAY: 0'-0" <br />NOTE: INSTALLER TO VERIFY RAFTER SIZE, SPACING AND SLOPED <br />SPANS, AND NOTIFY ANY DISCREPANCIES BEFORE PROCEEDING. <br />FIRE SETBACK <br />DEAD LOAD CALCULATIONS <br />BOM QUANTITY LBS/UNIT TOTAL <br />WEIGHT (LBS) <br />MODULES 22 47.84 1052.48 <br />MID-CLAMP 24 0.050 1.20 <br />END-CLAMP 40 0.050 2.00 <br />RAIL LENGTH 174 0.680 118.32 <br />SPLICE BAR 2 0.360 0.72 <br />FLASHFOOT 50 1.35 67.50 <br />MICRO-INVERTER 22 2.38 52.36 <br />TOTAL WEIGHT OF THE SYSTEM (LBS)1294.58 <br />TOTAL ARRAY AREA ON THE ROOF (SQ. FT.)462.29 <br />WEIGHT PER SQ. FT.(LBS)2.80 <br />WEIGHT PER PENETRATION (LBS)25.89 <br />ARRAY MP-02 <br />ALUMINIUM RAILS <br />2 X 4 RAFTERS@ 2'-0" <br />SPACING <br />ARRAY MP-01 <br />ARRAY MP-03 <br />ARRAY MP-04 <br />1'-6 <br />" <br />6' <br />3' <br />Structural <br />Only <br />1225 S Rosewood <br />Ave03/14/23