CONTRACTOR INFORMATION <br />CONTRACTOR:DVD CONSTRUCTION <br />ADDRESS:6500 E. CARNEGIE AVE., ANAHEIM, CA 92807 <br />PHONE: 949-864-9986 <br />LICENSE #/TYPE: 1029241 / A , B <br />TABLE OF CONTENTS <br />PAGE 1 COVER PAGE <br />PAGE 2 SITE PLAN <br />PAGE 3 PLOT PLAN <br />PAGE 4 SINGLE LINE DIAGRAM <br />PAGE 5 STRUCTURAL ATTACHMENT DETAIL <br />PAGE 6 LABELS AND WARNING SIGNAGE <br />PAGE 7 PV MODULE SPEC SHEET <br />PAGE 8 INVERTER SPEC SHEET <br />PAGE 9 UL LISTING <br />PAGE 10 GROUNDING <br />PAGE 11 RAPID SHUTDOWN <br />SYSTEM INFORMATION <br />SIZE(kw): 8.550 kW (DC) / 7.706 kW (CEC-AC) <br />MODULE TYPE: 19 CANADIAN SOLAR CS3W-450MB-AG <br />INVERTERS(S): 19 ENPHASE IQ8M-60-72-US <br />INVERTER TYPE: MICRO-INVERTER <br />SCOPE OF WORK <br />INSTALL <br />(19) ROOF MOUNTED PV SOLAR MODULES, <br />(19) ENPHASE IQ8M-60-72-US INVERTER(S)(240V). <br />DV <br />D <br /> <br />C <br />O <br />N <br />S <br />T <br />R <br />U <br />C <br />T <br />I <br />O <br />N <br />65 <br />0 <br />0 <br /> <br />E <br />. <br /> <br />C <br />A <br />R <br />N <br />E <br />G <br />I <br />E <br /> <br />A <br />V <br />E <br />. <br /> <br />A <br />N <br />A <br />H <br />E <br />I <br />M <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />8 <br />0 <br />7 <br />PH <br />O <br />N <br />E <br />: <br /> <br />9 <br />4 <br />9 <br />- <br />8 <br />6 <br />4 <br />- <br />9 <br />9 <br />8 <br />6 <br />LI <br />C <br />E <br />N <br />S <br />E <br />: <br /> <br />1 <br />0 <br />2 <br />9 <br />2 <br />4 <br />1 <br /> <br />/ <br /> <br />A <br /> <br />, <br /> <br />B <br />Co <br />n <br />t <br />r <br />a <br />c <br />t <br />o <br />r <br />' <br />s <br /> <br />S <br />i <br />g <br />n <br />a <br />t <br />u <br />r <br />e <br />: <br /> <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />Pr <br />o <br />j <br />e <br />c <br />t <br /> <br />N <br />a <br />m <br />e <br />8. <br />5 <br />5 <br />0 <br /> <br />k <br />W <br /> <br />( <br />D <br />C <br />) <br /> <br />/ <br /> <br />7 <br />. <br />7 <br />0 <br />6 <br /> <br />k <br />W <br /> <br />( <br />C <br />E <br />C <br />- <br />A <br />C <br />) <br />Ph <br />o <br />t <br />o <br />v <br />o <br />l <br />t <br />a <br />i <br />c <br /> <br />S <br />y <br />s <br />t <br />e <br />m <br />RA <br />Y <br />M <br />A <br />R <br /> <br />R <br />E <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />1 <br />3 <br />0 <br />6 <br /> <br />R <br />A <br />Y <br />M <br />A <br />R <br /> <br />S <br />T <br />. <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br /> <br />92 <br />7 <br />0 <br />3 <br />DA <br />T <br />E <br />: <br />1 <br />0 <br />/ <br />1 <br />2 <br />/ <br />2 <br />0 <br />2 <br />2 <br />DR <br />A <br />W <br />N <br /> <br />B <br />Y <br />: <br />AA <br />RE <br />V <br />I <br />S <br />I <br />O <br />N <br />S <br />: <br />Page <br />Title Block 11x17 <br />PROJECT INFORMATION <br />NAME:RAYMAR RESIDENCE <br />ADDRESS:1306 RAYMAR ST., SANTA ANA, CA 92703 <br />APN:010-022-27 <br />JURISDICTION: CITY OF SANTA ANA <br />OCCUPANCY GROUP: R3 <br />CONSTRUCTION TYPE: V-B <br />CO <br />V <br />E <br />R <br /> <br />P <br />A <br />G <br />E <br />· ALL MATERIALS, EQUIPMENT, INSTALLATION AND WORK PERFORMED SHALL <br />BE IN ACCORDANCE WITH THE FOLLOWING CODES: <br />- 2019 CBC / 2018 IBC <br />- 2019 CRC / 2018 IRC <br />- 2019 CEC / 2017 NEC <br />- 2019 CMC / 2018 IMC <br />- 2019 CPC / 2018 IPC <br />- 2019 CFC / 2018 IFC <br />- 2019 BUILDING ENERGY EFFICIENCY STANDARDS <br />· ALL EQUIPMENT SHALL BE LISTED AND LABELED BY A RECOGNIZED <br />ELECTRICAL TESTING LABORATORY AND L.A. TEST LAB. EQUIPMENT <br />INSTALLED SHALL BE PER ITS LISTING REQUIREMENTS AND THE <br />MANUFACTURER'S INSTRUCTIONS. NEC 110.2, 110.3, 690.4(B), 690.12(D). <br />· ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED, INCLUDING ALL ROOF <br />MOUNTED TRANSITION BOXES AND SWITCHES. <br />· ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN <br />ACCORDANCE WITH NEC ARTICLE 250. <br />· ALL PV CIRCUITS CONNECTED AND EQUIPMENT SHALL BE PROTECTED <br />AGAINST OVERCURRENT. OVERCURRENT DEVICES SHALL BE LISTED FOR <br />USE IN PV SYSTEMS. OVERCURRENT PROTECTIVE DEVICES SHALL NOT BE <br />REQUIRED FOR CIRCUITS WITH SUFFICIENT AMPACITY FOR THE HIGHEST <br />AVAILABLE CURRENT. CIRCUITS CONNECTED TO CURRENT LIMITED <br />SUPPLIES AND ALSO CONNECTED TO SOURCES HAVING HIGHER CURRENT <br />AVAILABILITY SHALL BE PROTECTED AT THE HIGHER CURRENT SOURCE <br />CONNECTION. [NEC 690.9] <br />· DISCONNECTING MEANS OF THE PV SYSTEM (INCLUDING RAPID SHUTDOWN <br />INITIATION) SHALL BE LOCATED IN A READILY ACCESSIBLE LOCATION NEAR <br />THE EQUIPMENT. [NEC 690.13,690.15] <br />· RAPID SHUTDOWN EQUIPMENT TO COMPLY WITH NEC 690.12. <br />· ENERGY STORAGE SYSTEM TERMINALS LOCATED MORE THAN 5 FEET AWAY <br />OR ON OPPOSITE SIDE OF WALL FROM CONNECTED EQUIPMENT MUST HAVE <br />DISCONNECTING MEANS IN ACCORDANCE WITH NEC 706.7(E) AND LABELED <br />PER 706.7(D). OVERCURRENT PROTECTION SHALL BE PROVIDED PER <br />706.21(F). <br />· THE UTILITY-INTERACTIVE INVERTERS SHALL AUTOMATICALLY DE-ENERGIZE <br />ITS OUTPUT TO THE CONNECTED ELECTRICAL PRODUCTION AND <br />DISTRIBUTION NETWORK VOLTAGE HAS BEEN RESTORED. [NEC 705.40] <br />· ALL CONDUCTORS IN EXPOSED OUTDOOR LOCATIONS SHALL BE LISTED AND <br />IDENTIFIED FOR USE IN DIRECT SUNLIGHT AND FOR THE APPLICATION. [NEC <br />690.31(C) THROUGH (F), 310.10(D)] <br />· INSULATION OF EXPOSED CONDUCTORS UNDER THE MODULES SHALL BE <br />USE-2 OR PV-WIRE TYPE FOR PV SYSTEMS (UL 4703 & 854 LISTED) [NEC <br />690.31(C)] <br />· FINE-STRANDED CABLE CONNECTIONS MUST BE MADE IN LUGS AND <br />TERMINALS TO ENSURE A THOROUGHLY GOOD CONNECTION WITHOUT <br />DAMAGING THE CONDUCTORS. [NEC 110.14(A)] <br />· FLEXIBLE, FINE-STRANDED CABLES SHALL BE TERMINATED ONLY WITH <br />TERMINALS, LUGS, DEVICES, OR CONNECTORS THAT ARE IDENTIFIED AND <br />LISTED FOR SUCH USE. [NEC 690.31(H), 110.14] <br />· ALL PV CIRCUIT CONDUCTORS SHALL BE MARKED ON EACH END AND <br />GROUPED FOR UNIQUE IDENTIFICATION. [NEC 690.31(B)] <br />· ALL EXTERIOR CONDUIT, FITTINGS, AND BOXES SHALL BE RAIN TIGHT AND <br />APPROVED FOR USE IN WET LOCATIONS. (NEC 314.15) <br />· ALL GROUNDED, (NEUTRAL), CONDUCTORS' INSULATION SHALL BE SOLID <br />WHITE, GRAY, OR WITH 3-WHITE STRIPES. [NEC 200.6, 200.7, 400.22; ALL <br />GROUNDING CONDUCTORS SHALL BE OF BARE WIRE WITHOUT COVERING, <br />OR WITH INSULATION OF GREEN OR GREEN WITH YELLOW STRIPES, NEC <br />250.119 & 400.23. THE COLOR OF UNGROUNDED CONDUCTORS SHALL BE <br />OTHER THAN FOR GROUNDED, (NEUTRAL), AND GROUNDING CONDUCTORS. <br />[NEC 310.110(C)] <br />· MAXIMUM CONDUCTOR LENGTH BETWEEN SUPPLY SIDE CONNECTION AND <br />OVERCURRENT PROTECTION IS 10FT. [NEC 705.31] <br />· CONNECTIONS ON THE LOAD SIDE OF THE SERVICE DISCONNECTING MEANS OF <br />THE OTHER SOURCE(S) AT ANY DISTRIBUTION EQUIPMENT ON THE PREMISES <br />SHALL BE IN ACCORDANCE WITH NEC 705.12(B). <br />· DC WIRING INSIDE A BUILDING MUST BE IN METALLIC TYPE RACEWAYS, CONDUITS, <br />ENCLOSURES, OR CABLE SHEATHINGS. [NEC 690.31(G)] <br />· METALLIC TYPE RACEWAYS, CONDUITS, ENCLOSURES, AND CABLE SHEATHS <br />CONTAINING CIRCUITS OVER 250-VOLTS TO GROUND MUST BE BONDED IN <br />ACCORDANCE WITH NEC 250.97. <br />· CONNECTORS SHALL BE OF LATCHING OR LOCKING TYPE. CONNECTORS THAT ARE <br />READILY ACCESSIBLE AND OPERATING AT OVER 30-VOLTS SHALL REQUIRE A TOOL <br />TO OPEN AND MARKED "DO NOT DISCONNECT UNDER LOAD" OR "NOT FOR <br />CURRENT INTERRUPTING." [NEC 690.33(C) & (E)(2)] <br />· FOR PV MODULES, EQUIPMENT GROUNDING CONDUCTOR (EGC) SMALLER THAN <br />#6-AWG SHALL BE PROTECTED FROM PHYSICAL DAMAGE BY AN IDENTIFIED <br />RACEWAY OR CABLE ARMOR, UNLESS INSTALLED WITHIN HOLLOW SPACES OF THE <br />FRAMING MEMBERS OF BUILDINGS OR STRUCTURES AND WHERE NOT SUBJECT TO <br />PHYSICAL DAMAGE. [NEC 690.46, 250.120(C)] <br />· THE INTERCONNECTION POINT SHALL BE ON THE SUPPLY SIDE OF ALL <br />GROUND-FAULT PROTECTION EQUIPMENT. [NEC 705.32] <br />· CABLES/WIRES THAT ARE SUBJECT TO PHYSICAL DAMAGE, SUCH AS THOSE NOT <br />LOCATED UNDER THE MODULES, MUST BE PROTECTED. [NEC 300.4] <br />· FOR ELECTRICAL SERVICE REPLACEMENTS, BONDING TO THE METAL PIPES OF <br />NATURAL GAS, HOT WATER, AND COLD WATER MUST BE PROVIDED. [NEC 250.104] <br />· GROUNDING ROD ELECTRODES SHALL BE INSTALLED 8-FT MINIMUM IN CONTACT <br />WITH SOIL AND MINIMUM 5/8-INCH DIAMETER. [NEC 250.52(A)(5), 250.53(G)] <br />· THE MARKINGS, "WARNING: PHOTOVOLTAIC POWER SOURCE", FOR DC RACEWAYS <br />AND CABLE ASSEMBLIES MUST BE NO MORE THAN 10-FT O.C.; AND IS SEPARATED <br />BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, FLOORS, OR BENDS ABOVE OR <br />BELOW PENETRATIONS. [NEC 690.31(G)(3)&(4)] <br />· WORKING CLEARANCES TO BE PROVIDED AT NEW AND EXISTING ELECTRICAL <br />EQUIPMENT. [NEC 110.26] <br />· POWER PRODUCTION SYSTEMS, AND ALL ASSOCIATED WIRING AND <br />INTERCONNECTIONS OPERATING IN PARALLEL WITH A PRIMARY POWER SOURCE <br />SHALL BE PERFORMED ONLY BY QUALIFIED PERSONS. [NEC 690.4(C), 705.8] <br />· LABELS SHALL BE REFLECTIVE, AND ALL LETTERS SHALL BE CAPITALIZED AND <br />SHALL BE A MINIMUM HEIGHT OF 3/8" IN WHITE ON A RED BACKGROUND. [NEC <br />690.31(G)(4) <br />· IDENTIFICATION OF POWER SOURCE RAPID SHUTDOWN AND LABELING SHALL BE IN <br />ACCORDANCE WITH NEC 690.56(C). <br />· SMOKE ALARMS AND CARBON MONOXIDE ALARMS ARE REQUIRED TO BE <br />RETROFITTED ONTO THE EXISTING DWELLING AS PER THE 2019 CRC. THESE <br />SMOKE ALARMS ARE REQUIRED TO BE IN ALL BEDROOMS, OUTSIDE EACH <br />BEDROOM, AND AT LEAST ONE ON EACH FLOOR OF THE HOUSE. CARBON <br />MONOXIDE ALARMS ARE REQUIRED TO BE RETROFITTED OUTSIDE EACH BEDROOM <br />AND AT LEAST ONE ON EACH FLOOR OF THE HOUSE. (CRC 314,315) <br />· SMOKE ALARMS AND CARBON MONOXIDE ALARMS ARE REQUIRED PER CRC <br />SECTIONS 314 AND 315 TO BE VERIFIED AND INSPECTED BY THE INSPECTOR IN THE <br />FIELD. <br />· A LADDER MUST BE PROVIDED FOR INSPECTIONS IN ACCORDANCE WITH Cal-OSHA <br />REGULATIONS, SECURED AND EXTENDING 3-FT ABOVE THE ROOF. <br />· ·ALL OF THE REQUIRED MARKINGS, SIGNS, AND LABELS MUST BE INSTALLED ON <br />ALL EQUIPMENT PRIOR TO ANY INSPECTIONS. <br />01 OF 11 <br />PHOTOVOLTAIC MODULES AND PANEL SYSTEMS INSTALLED ON OR INTEGRAL WITH BUILDINGS, OR TO <br />BE FREESTANDING (NOT ATTACHED TO BUILDINGS) SHALL BE TESTED, LISTED, AND IDENTIFIED WITH <br />A FIRE CLASSIFICATION (CLASS C MINIMUM) IN ACCORDANCE WITH UL1703. WHERE CLASS A OR B <br />ROOFING IS REQUIRED, THE PV SOLAR SYSTEM (PV PANEL & RACK) SHALL HAVE THE SAME <br />CLASS/TYPE RATING OR BETTER. <br />PHOTOVOLTAIC GENERAL NOTES <br />Bldg permit #101112706 <br />Elect permit #20177905 <br />Permits issued on 11/11/22 <br />1306 W Raymar St <br />11/14/22