mSANTA <br />AN &BUILDING <br />RESIDENTIAL <br />PHOTOVOLTAIC <br />CHECKLIST <br />CTY OPUA <br />PLANNING <br />Planning & Building Agency <br />Building Safety Division <br />20 Civic Center Plaza <br />P.O. Box 1988 (M-19) <br />Santa Ana, CA 92702 <br />(714) 647-5800GENCY <br />unAnAcantaanaAra <br />SOL-01 CBC 2019 <br />Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only <br />Instructions: The licensed contractor of record shall complete all sections,answer the ten questions and <br />Sign the certification section below.A copy of this form shall be attached to each of TWO sets of plans, of <br />minimum 11"x 17" size. If answering NO to any of the questions. plan check shal| be required <br />Project Address: 1306 W. Raymar St. <br />Contractor Company Name: DVD Construction <br />Contractor License Number: 1029241 <br />YES NO Are the following applicable to the proposed project? <br />Will the PV system layout provide the required three-foot wide clear access pathways <br />per Section 605.11 of the California Fire Code, and is this shown on the roof plan? <br />1. <br />2 Will the PV system be installed on a roof having only one roofing layer with no <br />overlays? <br />roof so that the plane of theWill the PV array be flush mounted to the existin <br />modules (panels) are parallel to the plane of the roof? <br />3. <br />4.Will the PV system weigh maximum 4 pounds per square feet or less? <br />5. O Will the PV system be installed where the modules do not overhang any roof edges <br />(such as eaves, gabled ends, ridges and hips)? <br />6.O Will the PV system be installed with a space of 2" minimum to 10" maximum between <br />the underside of modules and the surface of the roof? <br />7.will the PV system be installed without using any ballast system or counter-weight <br />system? <br />8. O Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet <br />and is this maximum horizontal spacing shown on the plans? <br />will the minimum 5/16" lag screws be installed with a minimum of 2-1/2 inch <br />embedment into roof rafters (with pre-drilled holes) and is this minimum embedment <br />shown on the plans? <br />10.Are ALL the structural pages of the plans stamped and signed by a California <br />licensed professional engineer? (including project specific site plan, PV layout, <br />anchorage spacing, anchorage details and manufacturer's PV support information.) <br />I certify under penalty of perjury under the laws of the State of California that the above is true: <br />Print Name: Dustin Do <br />Phone Number: 949-364-9986 <br />Email Address: ddo@dvdconstruction.com <br />.Signature AA <br />Date: 10/18/22 <br />Rev: 7/15/2021 <br />1306 W Raymar St <br />11/14/22