My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1306 W Raymar St - Plan
PBA
>
Building
>
ProjectDox
>
R
>
Raymar St
>
1306 W Raymar St
>
1306 W Raymar St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 11:57:11 AM
Creation date
6/1/2025 11:56:56 AM
Metadata
Fields
Template:
Plan
Permit Number
20177905
101112706
Full Address
1306 W Raymar St
Document Relationships
101112706 - Permit
(Permit - Plan)
Path:
\Building\Permits\R\Raymar St\1306 W Raymar St
20177905 - Permit
(Permit - Plan)
Path:
\Building\Permits\R\Raymar St\1306 W Raymar St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
141
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
General Footing <br />Affinity Design GroupLic. # : KW-06011953 <br />DESCRIPTION:Patio Footings <br />Code References <br />Calculations per ACI 318-14, IBC 2018, CBC 2019, ASCE 7-16 <br />Load Combinations Used : ASCE 7-16 <br />General Information <br />Material Properties Soil Design Values <br />1.50 <br />Analysis Settings <br />250.0 ksi <br />No <br />ksfAllowable Soil Bearing = <br />= <br />2.50 <br />60.0 <br />3,122.0 <br />145.0 =0.30 <br />Flexure =0.90 <br />Shear = <br />Values j <br />0.00180 <br />2.0 <br />Soil Passive Resistance (for Sliding) <br />1.0 <br />= <br />Increases based on footing plan dimension <br />Add Pedestal Wt for Soil Pressure No: <br />Use Pedestal wt for stability, mom & shear No: <br />Allowable pressure increase per foot of depth <br />=ksf <br />when max. length or width is greater than <br />=ft <br />: <br />= <br />Add Ftg Wt for Soil Pressure Yes <br />Yes:Use ftg wt for stability, moments & shears <br />when footing base is below ft <br />pcf <br />Increase Bearing By Footing Weight <br />=pcf <br />Min. Overturning Safety Factor <br />= <br />: 1 <br />Increases based on footing Depth0.750 <br />= <br />Soil/Concrete Friction Coeff. <br />Ec : Concrete Elastic Modulus <br />= <br />=Footing base depth below soil surface ft <br />=Allow press. increase per foot of depth ksf <br />= <br />: 1 1.0Min. Sliding Safety Factor = <br />= <br />Concrete Density <br />= <br />Min Allow % Temp Reinf. <br />ksif'c : Concrete 28 day strength <br />fy : Rebar Yield ksi <br />Min Steel % Bending Reinf. <br /># <br />Dimensions <br />Width parallel to X-X Axis 1.0 ft <br />Length parallel to Z-Z Axis <br />= <br />1.0 ft <br />= <br />Pedestal dimensions... <br />px : parallel to X-X Axis in <br />pz : parallel to Z-Z Axis in <br />Height = <br />= <br />in <br />Footing Thickness <br />= <br />24.0 in= <br />Rebar Centerline to Edge of Concrete... <br />= inat Bottom of footing 3.0 <br />Reinforcing <br /># <br />Bars parallel to X-X Axis <br />Reinforcing Bar Size <br />= <br />4 <br />Number of Bars <br />= <br />3.0 <br />Bars parallel to Z-Z Axis <br />Reinforcing Bar Size = 4 <br />Number of Bars = 3.0 <br />Bandwidth Distribution Check (ACI 15.4.4.2) <br />Direction Requiring Closer Separation <br />n/a <br /># Bars required within zone n/a <br /># Bars required on each side of zone n/a <br />Applied Loads <br />0.420 0.620 0.10 <br />D Lr <br />ksf <br />L S <br />P : Column Load <br />OB : Overburden = <br />k <br />W E <br />M-zz <br />V-x <br />= <br />=k <br />V-z k <br />M-xx = <br />k-ft= <br />k-ft <br />H <br />= <br />Raymar Street - Santa Ana Page 15 of 116 <br />1306 W Raymar St <br />11/14/22
The URL can be used to link to this page
Your browser does not support the video tag.