My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1306 W Raymar St - Plan
PBA
>
Building
>
ProjectDox
>
R
>
Raymar St
>
1306 W Raymar St
>
1306 W Raymar St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 11:57:11 AM
Creation date
6/1/2025 11:56:56 AM
Metadata
Fields
Template:
Plan
Permit Number
20177905
101112706
Full Address
1306 W Raymar St
Document Relationships
101112706 - Permit
(Permit - Plan)
Path:
\Building\Permits\R\Raymar St\1306 W Raymar St
20177905 - Permit
(Permit - Plan)
Path:
\Building\Permits\R\Raymar St\1306 W Raymar St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
141
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
JB <br />JB <br />3' <br />1'-6"1'-6" <br />1'-6" <br />1'-6" 1'-6" <br />3' <br />1'-6" <br />3' <br />3' <br />3' <br />(E) 225A MAIN SERVICE PANEL <br />120/240VAC SINGLE PHASE <br />(N) 60A AC DISCONNECT <br />2P - NON FUSIBLE <br />(N) NEMA 3R <br />JUNCTION BOX <br />EXTERIOR CONDUIT <br />(7/8"+ ABOVE ROOF) <br />(N) ENPHASE AC <br />COMBINER PANEL <br />SYSTEM SPECIFICATIONS <br />SIZE(kW):8.550 <br />MODULE:(19) <br />INVERTER(S): <br />(19) <br />INVERTER TYPE:MICRO-INVERTER <br />STRING SCHEDULE: <br />SYSTEM WEIGHT(lbs)1284.40 <br />ARRAY AREA(sq.ft)457.20 <br />ARRAY AZIMUTH(°):180 <br />LBS/SQ.FT 2.81 <br />CANADIAN SOLAR CS3W-450MB-AG <br />ENPHASE IQ8M-60-72-US <br />CIRCUIT 1 OF 11 MODULES <br />CIRCUIT 2 OF 8 MODULES <br />1 MICRO-INVERTER PER MODULE <br />(DC) / 7.706 kW (CEC-AC) <br />BUILDING SPECIFICATIONS <br />TYPE:S.F.R. <br />STORIES:1 <br />BUILDING HEIGHT:15 FT <br />BUILDING SQ.FT.:2411 SQ.FT. <br />ROOF SLOPE(S):23° / 14° <br />ROOF FRAME MEMBER: 2"X6" RAFTERS <br />O.C. SPACING (IN):24" <br />MAX SPAN:11'-9" IN BETWEEN SUPPORTS <br />MIN LAG BOLT <br />EMBEDMENT:2-1/2" <br />MOUNTING AND STANDOFF <br />SPECIFICATIONS <br />ROOFING MATERIAL:COMP. SHINGLE <br />RACKING SYSTEM:IRONRIDGE <br />STANDOFF DISTANCE: 4'-0" <br />MOUNTING TYPE:FLUSH TO ROOF <br />TILT LEG HEIGHT (IN.)N/A <br />HEIGHT OF PV MODULE <br />ABOVE ROOF SURFACE:4" TO 6" <br />MAX CANTILEVER 24" <br />DV <br />D <br /> <br />C <br />O <br />N <br />S <br />T <br />R <br />U <br />C <br />T <br />I <br />O <br />N <br />65 <br />0 <br />0 <br /> <br />E <br />. <br /> <br />C <br />A <br />R <br />N <br />E <br />G <br />I <br />E <br /> <br />A <br />V <br />E <br />. <br /> <br />A <br />N <br />A <br />H <br />E <br />I <br />M <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />8 <br />0 <br />7 <br />PH <br />O <br />N <br />E <br />: <br /> <br />9 <br />4 <br />9 <br />- <br />8 <br />6 <br />4 <br />- <br />9 <br />9 <br />8 <br />6 <br />LI <br />C <br />E <br />N <br />S <br />E <br />: <br /> <br />1 <br />0 <br />2 <br />9 <br />2 <br />4 <br />1 <br /> <br />/ <br /> <br />A <br /> <br />, <br /> <br />B <br />Co <br />n <br />t <br />r <br />a <br />c <br />t <br />o <br />r <br />' <br />s <br /> <br />S <br />i <br />g <br />n <br />a <br />t <br />u <br />r <br />e <br />: <br /> <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />Pr <br />o <br />j <br />e <br />c <br />t <br /> <br />N <br />a <br />m <br />e <br />8. <br />5 <br />5 <br />0 <br /> <br />k <br />W <br /> <br />( <br />D <br />C <br />) <br /> <br />/ <br /> <br />7 <br />. <br />7 <br />0 <br />6 <br /> <br />k <br />W <br /> <br />( <br />C <br />E <br />C <br />- <br />A <br />C <br />) <br />Ph <br />o <br />t <br />o <br />v <br />o <br />l <br />t <br />a <br />i <br />c <br /> <br />S <br />y <br />s <br />t <br />e <br />m <br />RA <br />Y <br />M <br />A <br />R <br /> <br />R <br />E <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />1 <br />3 <br />0 <br />6 <br /> <br />R <br />A <br />Y <br />M <br />A <br />R <br /> <br />S <br />T <br />. <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br /> <br />92 <br />7 <br />0 <br />3 <br />DA <br />T <br />E <br />: <br />1 <br />0 <br />/ <br />1 <br />2 <br />/ <br />2 <br />0 <br />2 <br />2 <br />DR <br />A <br />W <br />N <br /> <br />B <br />Y <br />: <br />AA <br />RE <br />V <br />I <br />S <br />I <br />O <br />N <br />S <br />: <br />Page <br />Title Block 11x17 <br />N <br />S <br />EW <br />- SOLAR PHOTOVOLTAIC SYSTEM TO BE INSTALLED <br /> ON RESIDENTIAL STRUCTURE. <br />-THIS SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM <br /> THE LOCAL JURISDICTION AND THE UTILITY IS OBTAINED. <br />-A 36-INCH WIDE PATHWAY SHALL BE PROVIDED TO THE EMERGENCY <br />ESCAPE AND RESCUE OPENING(S). [CRC R324.6.2.2] <br />-IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE <br /> GROUNDING ELECTRODE, IT IS THE CONTRACTOR'S RESPONSIBILITY <br /> TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE. <br />ROOF MOUNTED NOTES: <br />SCALE: 1" = 10' <br />R324.6.1 Pathways <br />R324.6.2 Setback at ridge <br />R324.6.2.1 Alternative setback at ridge <br />Exceptions: <br />1. These requirements shall not apply to structures designed and <br />constructed in accordance with the International Residential Code. <br />2. These requirements shall not apply to roofs with slopes of 2 <br />units vertical in 12 units horizontal or less. <br />ROOF ACCESS POINTS PER <br />2019 CRC, R324 (IFC 1204) <br />ADDITIONAL BUILDING DATA <br />TOTAL ARRAY AREA (SQ. FT.):457 <br />TOTAL PLAN VIEW ROOF AREA (SQ. FT.):2413 <br />OCCUPYING PV PERCENTAGE:18.95% <br />SPRINKLER SYSTEM INSTALLED (IFC 903.3.1.3)NO <br />03 OF 11 <br />PL <br />O <br />T <br /> <br />P <br />L <br />A <br />N <br />ROOF <br />ACCESS <br />POINT <br />(STREET-SIDE) <br />1306 W Raymar St <br />11/14/22
The URL can be used to link to this page
Your browser does not support the video tag.