Laserfiche WebLink
General Information: <br />B T = 30.25 ft <br />B L = 53.00 ft <br />H plt = 9.00 ft <br />H plt2 = 9 ft Two Story <br />pitch = 0.25 ft/ft θ = 14.00 <br />h peak = 22.17ft <br />Projected Roof Height:h pr = h peak - h plt = 13.17ft <br />Mean Bldg. Height:h mean = (h plt + h pr /2) = 15.58 ft <br />Wind Loads: <br />Basic Wind Speed (3 second gust - Figure 6-1):Vwind = 110 mph <br />Wind Load Importance Factor (Table 6-1): I w = 1.0 <br />Exposure Category :Exposure = C <br />Height and Exposure Coefficient (Figure 6-2):λ = 1.0 <br />Topographic Factor (Section 6.5.7)Kzt = 1.0 <br />10% of least horizontal dimension = 3.025 ft <br />0.4h mean = 6.23 ft <br />Min = 3.025 ft <br />3' min = 3 ft <br />a =3.03 ft <br />2a =6.05 ft <br />Roof Pitch: <br />Peak Roof Height: <br />Wind Evaluation for: <br />1306 W Raymar Street, Santa Ana, CA 92703 <br />Transverse Length (North-South): <br />Longitudinal Width (East-West): <br />Plate Height: <br />Plate Height_2nd flr: <br />Raymar Street - Santa Ana Page 61 of 114Raymar Street - Santa Ana Page 63 of 116 <br />1306 W Raymar St <br />11/14/22