My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1306 W Raymar St - Plan
PBA
>
Building
>
ProjectDox
>
R
>
Raymar St
>
1306 W Raymar St
>
1306 W Raymar St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 11:57:11 AM
Creation date
6/1/2025 11:56:56 AM
Metadata
Fields
Template:
Plan
Permit Number
20177905
101112706
Full Address
1306 W Raymar St
Document Relationships
101112706 - Permit
(Permit - Plan)
Path:
\Building\Permits\R\Raymar St\1306 W Raymar St
20177905 - Permit
(Permit - Plan)
Path:
\Building\Permits\R\Raymar St\1306 W Raymar St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
141
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
DV <br />D <br /> <br />C <br />O <br />N <br />S <br />T <br />R <br />U <br />C <br />T <br />I <br />O <br />N <br />65 <br />0 <br />0 <br /> <br />E <br />. <br /> <br />C <br />A <br />R <br />N <br />E <br />G <br />I <br />E <br /> <br />A <br />V <br />E <br />. <br /> <br />A <br />N <br />A <br />H <br />E <br />I <br />M <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />8 <br />0 <br />7 <br />PH <br />O <br />N <br />E <br />: <br /> <br />9 <br />4 <br />9 <br />- <br />8 <br />6 <br />4 <br />- <br />9 <br />9 <br />8 <br />6 <br />LI <br />C <br />E <br />N <br />S <br />E <br />: <br /> <br />1 <br />0 <br />2 <br />9 <br />2 <br />4 <br />1 <br /> <br />/ <br /> <br />A <br /> <br />, <br /> <br />B <br />Co <br />n <br />t <br />r <br />a <br />c <br />t <br />o <br />r <br />' <br />s <br /> <br />S <br />i <br />g <br />n <br />a <br />t <br />u <br />r <br />e <br />: <br /> <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />Pr <br />o <br />j <br />e <br />c <br />t <br /> <br />N <br />a <br />m <br />e <br />8. <br />5 <br />5 <br />0 <br /> <br />k <br />W <br /> <br />( <br />D <br />C <br />) <br /> <br />/ <br /> <br />7 <br />. <br />7 <br />0 <br />6 <br /> <br />k <br />W <br /> <br />( <br />C <br />E <br />C <br />- <br />A <br />C <br />) <br />Ph <br />o <br />t <br />o <br />v <br />o <br />l <br />t <br />a <br />i <br />c <br /> <br />S <br />y <br />s <br />t <br />e <br />m <br />RA <br />Y <br />M <br />A <br />R <br /> <br />R <br />E <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />13 <br />0 <br />6 <br /> <br />R <br />A <br />Y <br />M <br />A <br />R <br /> <br />S <br />T <br />. <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br /> <br />92 <br />7 <br />0 <br />3 <br />DA <br />T <br />E <br />: <br />10 <br />/ <br />1 <br />2 <br />/ <br />2 <br />0 <br />2 <br />2 <br />DR <br />A <br />W <br />N <br /> <br />B <br />Y <br />: <br />AA <br />RE <br />V <br />I <br />S <br />I <br />O <br />N <br />S <br />: <br />Page <br />Title Block 11x17 <br />10 OF 11 <br />GR <br />O <br />U <br />N <br />D <br />I <br />N <br />G <br />RAIL TO RAIL <br />BONDING <br />#6 BARE <br />COPPER WIRE <br />INVERTER <br />(IF USED)MSP <br />CONTINUOUS <br />GROUND <br />PER SLD <br />JBOX GROUND <br />BUSHINGS REQ. <br />MODULE <br />RAIL <br />SOLAR <br />METER <br />(IF REQ) <br />(A) <br />(1) BOND STRIP GROUNDS RAIL TO <br />RAIL SPLICES - STAR WASHERS USED <br />TO BOND RAIL TO BONDING STRIP <br />(2) SPLICE BAR, SELF-TAP SCREWS <br />JOIN RAILS. BONDING STRIPS USED <br />ON RAILS WITH GROUND LUGS. <br />(1) (2) <br />(3) <br />IF SPLICE BAR HAS INTEGRATED <br />GROUND, BONDING STRIP IS <br />NOT NECESSARY. <br />(3) WHERE NEITHER BONDING STRIP, INTEGRATED <br />GROUNDING SPLICE BAR, OR INTEGRATED <br />GROUNDING MIDCLAMP ARE USED, UL 2703 <br />APPROVED GROUND LUG WITH #6 BARE COPPER <br />SHALL BE USED TO GROUND SPLICED RAILS. <br />USE METHOD (2) <br />(1) <br />(C) RAIL SPLICE GROUNDING <br />(C) <br />#6 BARE <br />COPPER <br />RAIL <br />1 <br />RAIL <br />2 <br />EITHER METHOD 1-3 PER MANUFACTURERS INSTALL INSTRUCTIONS <br />CONDUIT <br />GROUNDING <br />BUSHING <br />WITH <br />LAY-IN LUG <br />ENCLOSURE <br />CONTINUOUS <br />GROUND <br />STRIP <br />INSULATION <br />CONDUIT GROUNDING DETAIL <br />EQUIPMENT GROUND <br />BUSHINGS REQ. FOR <br />SYSTEMS OVER 250V <br />(A) GROUNDING MID CLAMP <br />EACH GROUNDING MID CLAMP PIERCES THROUGH THE <br />ANODIZED COATINGS OF BOTH THE MODULE FRAME AND THE <br />MOUNTING RAIL TO FORM SECURE ELECTRICAL BONDS, WHICH <br />ARE REPEATED THROUGHOUT THE ARRAY. <br />MIDCLAMP TEETH <br />MODULE PENETRATION <br />SERRATED T-BOLT BONDS <br />CLAMP TO RAIL <br />COMPRESSION <br />FITTING <br />LOCK NUT <br />1306 W Raymar St <br />11/14/22
The URL can be used to link to this page
Your browser does not support the video tag.