Laserfiche WebLink
Ex <br />p <br />e <br />d <br />i <br />t <br />e <br />d <br /> <br />P <br />e <br />r <br />m <br />i <br />t <br /> <br />P <br />r <br />o <br />c <br />e <br />s <br />s <br /> <br />f <br />o <br />r <br /> <br />P <br />V <br /> <br />S <br />y <br />s <br />t <br />e <br />m <br />s <br /> <br />5 <br />Notes for Standard String System Electrical Diagram <br />Contractor Name, <br />Address and Phone: <br />_________________ <br />_________________ <br />_________________ <br />_________________ <br />Notes for One-Line Standard Electrical <br />Diagram for Single-Phase PV Systems <br />Site Name: __________________________ <br />Site Address: ________________________ <br />System AC Size: ______________________ <br />SIZE FSCM NO DWG NO REV <br />SCALE NTS Date: SHEET <br />Drawn By: <br />Checked By: <br />MAX POWER-POINT CURRENT (IMP) <br />MAX POWER-POINT VOLTAGE (VMP) <br />OPEN-CIRCUIT VOLTAGE (VOC) <br />SHORT-CIRCUIT CURRENT (ISC) <br />MAX SERIES FUSE (OCPD) <br />MAXIMUM POWER (PMAX) <br />MAX VOLTAGE (TYP 600VDC) <br />VOC TEMP COEFF (mV/oC or %/oC ) <br />IF COEFF SUPPLIED, CIRCLE UNITS <br /> A <br />V <br />V <br />A <br />A <br />W <br />V <br />MODULE MAKE <br />MODULE MODEL <br />PV MODULE RATINGS @ STC (Guide Section 5) <br />MAX DC VOLT RATING <br />MAX POWER @ 40oC <br />NOMINAL AC VOLTAGE <br />MAX AC CURRENT <br />MAX OCPD RATING <br />V <br />W <br />V <br />A <br />A <br />INVERTER MAKE <br />INVERTER MODEL <br />INVERTER RATINGS (Guide Section 4) <br />1) IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH, DOES THIS SWITCH MEET THE <br />REQUIREMENT? YES NO N/A <br />2) IF GENERATION METER REQUIRED, DOES THIS METER SOCKET MEET THE <br />REQUIREMENT? YES NO N/A <br />3) SIZE PHOTOVOLTAIC POWER SOURCE (DC) CONDUCTORS BASED ON MAX <br />CURRENT ON NEC 690.53 SIGN OR OCPD RATING AT DISCONNECT <br />4) SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDING TO INVERTER <br />OCPD AMPERE RATING. (See Guide Section 9) <br />5) TOTAL OF ______ INVERTER OCPD(s), ONE FOR EACH INVERTER. DOES TOTAL <br />SUPPLY BREAKERS COMPLY WITH 120% BUSBAR EXCEPTION IN 690.64(B)(2)(a)? <br />YES NO <br />NOTES FOR INVERTER CIRCUITS (Guide Section 8 and 9): <br />1.) LOWEST EXPECT AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN <br />EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO <br />INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP ______oC <br />2.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST <br />MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO <br />INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMPERATURE _____oC <br />2.) 2005 ASHRAE FUNDEMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED <br />47oC IN THE UNITED STATES (PALM SPRINGS, CA IS 44.1 oC). FOR LESS THAN 9 <br />CURRENT-CARRYING CONDUCTORS IN ROOF-MOUNTED SUNLIT CONDUIT AT <br />LEAST 0.5" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF <br />47oC OR LESS (ALL OF UNITED STATES), <br /> a) 12 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES <br />WITH Isc OF 7.68 AMPS OR LESS WHEN PROTECTED BY A 12-AMP OR SMALLER <br />FUSE. <br /> b) 10 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES <br />WITH Isc OF 9.6 AMPS OR LESS WHEN PROTECTED BY A 15-AMP OR SMALLER <br />FUSE. <br />NOTES FOR ARRAY CIRCUIT WIRING (Guide Section 6 and 8 and Appendix D): <br />OCPD = OVERCURRENT PROTECTION DEVICE <br />NATIONAL ELECTRICAL CODE ® REFERENCES <br />SHOWN AS (NEC XXX.XX) <br />NOTES FOR ALL DRAWINGS: <br />SIGNS–SEE GUIDE SECTION 7 <br />SIGN FOR DC DISCONNECT <br />SIGN FOR INVERTER OCPD AND <br />AC DISCONNECT (IF USED) <br />RATED MPP CURRENT <br />RATED MPP VOLTAGE <br />MAX SYSTEM VOLTAGE <br />MAX CIRCUIT CURRENT <br />A <br />V <br />V <br />A <br />PHOTOVOLTAIC POWER SOURCE <br />WARNING: ELECTRICAL SHOCK <br />HAZARD–LINE AND LOAD MAY BE <br />ENERGIZED IN OPEN POSITION <br />AC OUTPUT CURRENT <br />NOMINAL AC VOLTAGE <br /> A <br />V <br />SOLAR PV SYSTEM <br />AC POINT OF CONNECTION <br />THIS PANEL FED BY MULTIPLE <br />SOURCES (UTILITY AND SOLAR) <br />TROY STOKES <br />2491 ALLUVIAL AVE #22 CLOVIS, CA 93611 1302 S OLIVE ST <br />CONTRACTOR LIC#: #904259 <br />1302 S OLIVE ST SANTA ANA, CA, 92707 <br />PHONE #: 559-797-2232 <br />7.067 KW <br />1302 S Olive St <br />02/23/23