Laserfiche WebLink
(11)HANWHA Q CELL QPEAK DUO BLK ML-G10+ 400W ,MODULES WITH <br />(11)ENPAHSE IQ8PLUS-72-2-US (240V)(SI-1) <br />(1) BRANCH OF (11) MICRO-INVERTERS <br />(N)JUNCTION <br />BOX <br />2 1 <br />ENPHASE Q CABLE <br />DC CONDUCTORS <br />AC CONDUCTORS <br />3 15A <br />AC COMBINER BOX <br />X-IQ-AM1-240-4 120/240 <br />NEMA 3R INSTALL <br />(1)20A PV 2P BREAKERS <br />(ONLY FOR SOLAR, NO <br />LOADS TO BE ADDED) <br />ENPHASE IQ <br />COMBINER 4 <br />20A <br />(N)60A AC <br />DISCONNECT <br />AC DISCONNECT <br />NON FUSED 60A, <br />120/240V, 2P <br />(E)100A CENTER FED <br />MAIN PANEL <br />UTILITY <br />GRID <br />(E <br />) <br />1 <br />0 <br />0 <br />A <br /> <br />M <br />A <br />I <br />N <br />BR <br />E <br />A <br />K <br />E <br />R <br />(GMA)GENERATION METER ADAPTER <br />EXISTING 120/240V 1PH 60HZ <br />METER#:SCE <br />222013-409028M <br />(E) GROUND <br />ELECTRODE <br />4 <br />N <br />G <br />MODULE SPECIFICATION <br />MODEL <br />HANWHA Q CELL <br />QPEAK DUO BLK <br />ML-G10+ 400W <br />MODULE POWER @ STC 400W <br />OPEN CIRCUIT VOLTAGE:Voc 45.30V <br />MAX POWER VOLTAGE:Vmp 37.13V <br />SHORT CIRCUIT CURRENT:Isc 11.14A <br />MAX POWER CURRENT:Imp 10.77A <br />ADDRESS:1322 SOUTH RENE DRIVE, <br />SANTA ANA, CA 92704 <br />33.729767, -117.891024 <br />APN: 109-37-413 <br />CUSTOMER INFORMATION <br />NAME:RUBEN RODRIGUEZ <br />DATE:10/28/2022 <br />SCALE:AS NOTED REV:A <br />AHJ:CA - CITY OF SANTA ANA <br />UTILITY:SCE <br />PRN NUMBER:MAS-67317 <br />PAPER SIZE:17"X11" <br />SOLARPLEX LLC <br />Dba MARAVILLA CONSTRUCTION <br /> License#:1056065 <br /> 5902 FIRESTONE BLVD <br /> SOUTH GATE, CA 90280 <br /> TEL:(562) 806-6000 <br /> FAX:(562) 806-4006 <br />DRAFTED BY: <br />A.ROSHAN <br />QC'ED BY:H.RAJ <br />SINGLE LINE DIAGRAM <br />E-01 <br />1. CONDUCTORS EXPOSED TO SUNLIGHT <br />SHALL BE LISTED AS SUNLIGHT <br />RESISTANT PER CEC 310.10(D). <br />2. CONDUCTORS EXPOSED TO WET <br />LOCATIONS SHALL BE SUITABLE FOR <br />USE IN WET LOCATIONS PER CEC <br />310.10(C). <br />3. MAXIMUM DC/AC VOLTAGE DROP SHALL <br />BE NO MORE THAN 2%. <br />4. ALL CONDUCTORS SHALL BE IN <br />CONDUIT UNLESS OTHERWISE NOTED. <br />5. BREAKER/FUSE SIZES CONFORMS TO <br />CEC 240.6 CODE SECTION. <br />6. AC GROUNDING ELECTRODE <br />CONDUCTOR SIZED PER CEC 250.66. <br />7. AMBIENT TEMPERATURE CORRECTION <br />FACTOR IS BASED ON CEC 690.31(A). <br />8. AMBIENT TEMPERATURE ADJUSTMENT <br />FACTOR IS BASED ON CEC 310.15(B)(2). <br />9. MAX. SYSTEM VOLTAGE CORRECTION IS <br />PER CEC 690.7. <br />10. CONDUCTORS ARE SIZED PER WIRE <br />AMPACITY TABLE CEC 310.15(B)(16). <br />ELECTRICAL NOTESSINGLE LINE DIAGRAM: DC SYSTEM SIZE - 4400W, AC SYSTEM SIZE - 3190W, CEC AC RATING:3964W <br />AC WIRE SIZING CALCULATIONS BASED OF FOLLOWING EQUATIONS >> <br />· REQUIRED CONDUCTOR AMPACITY: INVERTER OUTPUT CURRENT X #OF <br />INVERTERS = MAX CURRENT PER 690.8(A)(3) X 125% = MAX CURRENT PER <br />690.8(B)(1) <br />· CORRECTED AMPACITY CALCULATIONS: AMPACITY X TEMPERATURE DERATE <br />FACTOR X CONDUIT FILL DERATE = DERATED CONDUCTOR AMPACITY PER <br />690.8(B)(2) <br />· DERATED CONDUCTOR AMPACITY CHECK: MAX CURRENT PER 690.8(A)(3) <br /><DERATED CONDUCTOR AMPACITY <br />AC WIRE CALCULATIONS:- MATERIAL:COPPER & TEMPERATURE RATING:90°C <br />TAG ID REQUIRED CONDUCTOR AMPACITY CORRECTED AMPACITY CALCULATION DERATED CONDUCTOR AMPACITY CHECK <br />1 1.21 X 11 = 13.31 X 1.25 = 16.64A 30 X 0.87 X 1 =26.10A 16.64A <26.10A <br />2 1.21 X 11 = 13.31 X 1.25 = 16.64A 40 X 0.87 X 1 =34.80A 16.64A <34.80A <br />3 1.21 X 11 = 13.31 X 1.25 = 16.64A 40 X 0.87 X 1 =34.80A 16.64A <34.80A <br />4 1.21 X 11 = 13.31 X 1.25 = 16.64A 75 X 0.87 X 1 =65.25A 16.64A <65.25A <br />CONDUIT SCHEDULE <br />TAG ID CONDUIT SIZE CONDUCTOR NEUTRAL GROUND <br />1 NONE (2) 12AWG ENPHASE Q CABLE <br />PER BRANCH CIRCUIT NONE (1) 6AWG BARE COPPER <br />2 3/4"EMT (2) 10AWG THHN/THWN-2 NONE (1) 8AWG THHN/THWN-2 <br />3 3/4"EMT (2) 10AWG THHN/THWN-2 (1) 10AWG THHN/THWN-2 (1) 8AWG THHN/THWN-2 <br />4 3/4"EMT (2) 6AWG THHN/THWN-2 (1) 6AWG THHN/THWN-2 (1) 8AWG THHN/THWN-2 <br />ELECTRICAL CALCULATION <br />MICRO INVERTER SPECIFICATIONS <br />MODEL ENPAHSE IQ8PLUS-72-2-US <br />(240V)(SI-1) <br />POWER RATING 290W <br />MAX OUTPUT CURRENT 1.21A <br />CEC WEIGHTED EFFICIENCY 97% <br />MAX NO OF MICRO <br />INVERTERS/BRANCH 13 <br />MAX DC VOLTAGE 60V <br />NOTE: <br />1. EACH MICRO INVERTER IS RAPID SHUTDOWN COMPLIANT. <br />NOTE: <br />MAIN PANEL RATING:100A, MAIN BREAKER RATING:100A <br />LINE SIDE TAP: 100% ALLOWABLE BACKFEED IS =100A <br />OCPD CALCULATIONS: <br />INVERTER OVERCURRENT PROTECTION= INVERTER O/P I X CONTINUOUS LOAD(1.25) <br />=1.21x1.25x11=16.64A=>PV BREAKER = 20A <br />TOTAL REQUIRED PV BREAKER SIZE / FUSE SIZE=>20A PV BREAKER <br />1322 S Rene Dr - <br />2017787611/22/22