My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1327 S Joane Way - Plan
PBA
>
Building
>
ProjectDox
>
J
>
Joane Way
>
1327 S Joane Way
>
1327 S Joane Way - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 11:57:12 AM
Creation date
6/1/2025 11:57:02 AM
Metadata
Fields
Template:
Plan
Permit Number
20177827
101112596
Full Address
1327 S Joane Way
Document Relationships
101112596 - Permit
(Permit - Plan)
Path:
\Building\Permits\J\Joane Way\1327 S Joane Way
20177827 - Permit
(Permit - Plan)
Path:
\Building\Permits\J\Joane Way\1327 S Joane Way
Stamp
ID:
1
Creator:
Import Agent
Created:
6/1/2025 11:57 AM
Modified:
5/30/2025 12:32 PM
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Wyssling Consulting <br />76 N. Meadowbrook Drive <br />Alpine, UT 84004 <br />(201) 874-3483 <br />swyssling@wysslingconsulting.com <br />V = 95 Basic Wind Speed Telles Residence <br />Exposure C ASCE 7-16, Section 26.7 1327 South Joane Way <br />Kz = 0.85 Velocity Pressure Coefficient, ASCE 7-16, Figure 26.10-1 Santa Ana, CA <br />Kzt = 1 Topographic Factor, ASCE 7-16, Section 26.8.2 <br />Kd = 0.85 Directionality Factor, ASCE 7-16, Section 26.6 <br />Ke = 0.988 Ground Elevation Factor, ASCE 7-16, Section 26.9 <br />qh = 16.5 psf qh = 0.00256KzKztKdKeV2 (ASCE 7-16 Eq. 26.10-1) <br />Roof Angle = 10 deg <br />Roof Type Gable <br />sanchor = 48 in Horizontal spacing of roof anchors <br />Atrib = 12.73 sf Panel Area tributary to each roof anchor <br />GCp External Pressure Coefficient, ASCE 7-16, Figure 30.3-2 <br />Roof Zone Zone 1 2e 2n 2r 3e 3r <br />-2.00 -2.00 -2.98 -2.98 -2.98 -3.55 <br />ga = 0.79 Pressure Equalization Factor, ASCE 7-16 Figure 29.4.-8 <br />gE = 1.00 Edge Array Factor, ASCE 29.4.4 edges < 0.5*building height, and panel spacing < 4ft. <br />pnet = qhGCpgEga = Design Wind Pressure, ASCE 7-16, Equation 29.4-7 <br />Roof Zone 1 2e 2n 2r 3e 3r <br />-26 psf -26 psf -39 psf -39 psf -39 psf -46 psf Min Pressure = -16 psf <br />Use 26 psf Use 26 psf Use 39 psf Use 39 psf Use 39 psf Use 46 psf ULTIMATE <br />x 0.6 = 16 psf 16 psf 23 psf 23 psf 23 psf 28 psf ALLOWABLE <br />Connection to Existing Roof Framing <br />F.S. = 1 Additional Factor of Safety applied to withdrawl force, if desired <br />Atrib = 12.7 ft2 <br />DLpanel = 3 psf <br />Roof Zone 1 2e 2n 2r 3e 3r <br />Wuplift = 26 psf 26 psf 39 psf 39 psf 39 psf 46 psf <br />Plag = F.S. x Atrib x (0.6D - 0.6W) = Withdrawl force for each roof anchor <br />Roof Zone 1 2e 2n 2r 3e 3r <br />-178.9 lbs -178.9 lbs -275.9 lbs -275.9 lbs -275.9 lbs -332.3 lbs <br />Connection Capacity <br />db = 5/16 in Lag Screw diameter <br />Dpen = 2 1/2 in Lag Screw penetration into existing framing member <br />No. of Screws 1 Screws per Connection <br />Species of wood framing <br />CD = 1.6 Load Duration Factor for Wind Loading, NDS Table 2.3.2 <br />Ct = 0.7 Temperature Factor, NDS Table 10.3.4 <br />W = 266 lb/in Withdrawl Capacity, NDS Equation 11.2-1 <br />W' = CD x Ct x W = 298 lb/in Adjusted withdrawl value <br />Pallow = Dpen x W' = 745 lbs <br />Roof Zone 1 2e 2n 2r 3e 3r <br />DEMAND = 179 lbs 179 lbs 276 lbs 276 lbs 276 lbs 332 lbs <br />CAPACITY = 745 lbs 745 lbs 745 lbs 745 lbs 745 lbs 745 lbs <br />up to72in ok up to72in ok up to72in ok up to72in ok up to72in ok up to72in ok <br />This analysis calculates the <br />capacity of the lag screws <br />only. For capacity of the <br />complete mounting system, <br />please see manufacturer's <br />recommendations. <br />Douglas Fir-Larch <br />Wind Uplift <br />Rooftop Solar Panels Parallel to Roof Surface <br />ASCE 7-16, Section 29.4.4 <br />1327 S Joane Way <br />11/04/22
The URL can be used to link to this page
Your browser does not support the video tag.