Laserfiche WebLink
SW_LINE B 1st Floor Passe d <br />Exterior Wall Drection X Location:(16.18, 0.00) <br />Loads <br />SECTION D1X_ROOF: W=1220 LB, E=1295 LB (27.25ft) <br />Wall Self-Weight Seismic = 313 LB <br /> Strap <br />She arwall De sign USE TYPE: SW1 <br />Total Length (ft): 29.00 Total panel Length (ft): 8.00 ρ = 1.3 <br />Pane l Width (ft)Ne t <br />He ight (ft)H/W Actual (plf)Allowable <br />(plf) <br />Adjuste d Allowable (plf)SW Type Re marksWindSeismicWindSeismic <br />A 8.00 10.00 1.25 152 250 260 364 260 SW1 <br />Ov e rturning Force s <br />Pane l Le ft Force s (lb)Right Force s (lb) <br />Dup Ddown L Lr S W E Dup Ddown L Lr S W E <br />A 680 226 0 0 0 1582 1993 680 226 0 0 0 1582 1993 <br />Holdown & De fle ction Che ck <br />Pane l Width (ft) <br />Ne t <br />He ight <br />(ft) <br />Le ft <br />Ratio <br />Right <br />Ratio <br />Pane l <br />De fle ction (in) <br />Uplift <br />(LB) <br />Down <br />(LB)Holdown/Post Uplift <br />(LB) <br />Down <br />(LB)Holddown/Post Actual Allowable <br />A 8.00 10.00 2282 2850 HDU2/4X4 0.74/0.37 2282 2850 HDU2/4X4 0.74/0.37 1.604 2.400 <br />vG23.06.30 <br />: <br />: <br />: <br />: <br />Com pany <br />Project 1402 W 10th <br />Job No.231014 <br />Plan N/A <br />: <br />: <br />: <br />: <br />Designed D.B. <br />Checked P.P. <br />Date 12/28/2023 <br />Client N/A <br />TIC Structure Design 2023 1402 W 10th St & Unit #2 - <br />101117923-245/8/2024