My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1402 W Meriday Ln - Plan
PBA
>
Building
>
ProjectDox
>
M
>
Meriday Ln
>
1402 W Meriday Ln
>
1402 W Meriday Ln - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 11:58:04 AM
Creation date
6/1/2025 11:57:58 AM
Metadata
Fields
Template:
Plan
Permit Number
20181605
101117563
Full Address
1402 W Meriday Ln
Document Relationships
101117563 - Permit
(Permit - Plan)
Path:
\Building\Permits\M\Meriday Ln\1402 W Meriday Ln
20181605 - Permit
(Permit - Plan)
Path:
\Building\Permits\M\Meriday Ln\1402 W Meriday Ln
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
• RPO switch <br />• Individual ACPV circuit breakers <br />• Installed knife blade handle disconnect switch located in series with all backup side <br />solar sources <br />The RSD initiation devices for the non-backup side circuits can be one of the following: <br />• Manufacturer-specific RSD initiation device <br />• Main service breaker (if PV inverter(s) are located within the array boundary <br />(i.e., microinverters, etc.)) <br />• Individual solar circuit breakers <br />• Installed knife blade handle disconnect switch located in series with all non-backup <br />solar sources <br />The rapid shutdown switch must have a label that includes the following wording located <br />on or no more than three feet from the switch [690.12(D)(2)]: <br />RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM <br />2023 NEC Article 706.15 Disconnecting Means <br />Means shall be provided to disconnect the SunVault systems power output circuit(s) from <br />all premises wiring. The disconnecting means must be readily accessible and must <br />comply with at least one of the following: <br />1. Located within the SunVault enclosure. <br />2. Located within sight AND within 10 feet of the SunVault enclosure. <br />3. Where the disconnecting means is not located within sight AND within 10’ of the <br />SunVault enclosure, the disconnecting means must be capable of being locked in the <br />open position. <br />Note: The ESS disconnect is the 40 A ESS breaker located in the Hub+ <br />backup pan, and can be locked open with the Eaton BRLW handle lockoff <br />installation accessory part. See the Additional Information section below. <br />1402 W Meriday Ln - <br />201816051/10/2024
The URL can be used to link to this page
Your browser does not support the video tag.