My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1402 W Meriday Ln - Plan
PBA
>
Building
>
ProjectDox
>
M
>
Meriday Ln
>
1402 W Meriday Ln
>
1402 W Meriday Ln - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 11:58:04 AM
Creation date
6/1/2025 11:57:58 AM
Metadata
Fields
Template:
Plan
Permit Number
20181605
101117563
Full Address
1402 W Meriday Ln
Document Relationships
101117563 - Permit
(Permit - Plan)
Path:
\Building\Permits\M\Meriday Ln\1402 W Meriday Ln
20181605 - Permit
(Permit - Plan)
Path:
\Building\Permits\M\Meriday Ln\1402 W Meriday Ln
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
NO <br />NONO <br />EGC: Bare CU #6 <br />BRANCH CIRCUIT <br />FROM PV ARRAY TO <br />JUNCTION BOX <br />#12 2A --1 <br />CONDUCTOR / CONDUIT SCHEDULE <br />DESCRIPTION & <br />CONDUCTOR TYPE <br />CONDUCTOR SIZE <br />(AWG)CONDUIT/CABLE TYPE CONDUIT SIZENUMBER OF <br />CONDUCTORS <br />1 <br />TAG <br /> GROUNDED (INCLUDE GEC) UNGROUNDED9 <br />INSTALLATION NOTES <br />CHECK BOX FOR WHETHER SYSTEM IS GROUNDED <br />OR UNGROUNDED: <br />FOR UNGROUNDED SYSTEMS: <br />x DC OCPD DISCONNECT BOTH CONDUCTORS OF <br />EACH SOURCE CIRCUIT. <br />x UNGROUNDED CONDUCTORS MUST BE <br />IDENTIFIED PER 210.5(C). WHITE FINISHED <br />CONDUCTORS ARE NOT PERMITTED. <br />DC / DC CONVERTERS NO <br />SOURCE CIRCUIT JUNCTION BOX <br />SUNVAULT ESS <br />SUNVAULT BATTERY INVERTER <br />SOLAR LOAD CENTER <br />PV PRODUCTION METER <br />SEPARATE AC DISCONNECT <br />HEAT DETECTOR <br />YES <br />NO <br />BACK UP LOAD CENTER <br />NON-BACK UP LOAD CENTER <br />EV SUPPLY EQUIPMENT <br />NO <br />DESCRIPTION <br />REMOTE POWER OFF SWITCH <br />HUB+ <br />x RELOCATE APPLICABLE BREAKERS FROM (E) MSP <br />TO APPROPRIATE PANELS OF (N) HUB+. <br />x INSTALL (N) 60A, 2P SUB FEED BREAKER IN THE <br />(E) MSP AND FEED (N) HUB+ WITH THIS <br />BREAKER. <br />x INSTALL (N) 100A BACKUP LOAD CENTER. <br />INSTALL (N) 50A, 2P BREAKER ON THE BACKUP <br />BUS OF (N) HUB+ AND FEED (N) BACKUP LOAD <br />CENTER WITH THIS BREAKER. <br />x INSTALL A SECOND SET OF CONSUMPTION CTS <br />IN PARALLEL AND BUNDLE THE REMAINING <br />LOADS IN THE MSP. <br />x INSTALL (N) HEAT DETECTOR. <br />x RETAIN 30A, 2P AC AND 40A, 2P OVEN IN THE <br />MSP. <br />x NEED TO INSTALL 5/8" TYPE X GYPSUM BEHIND <br />THE ESS AS A MINIMUM ON UNFINISHED WALLS. <br />x SEE PVE-6 FOR DETAILS. <br />20A, 2PGRID SENSE <br />IN ESS NO <br />N <br />- <br />B <br />A <br />C <br />K <br />U <br />P <br /> <br />B <br />U <br />S <br />(1 <br />2 <br />5 <br />A <br /> <br />M <br />A <br />X <br />) <br />NO <br />15A, 1P HD <br />YES <br />10 <br />(1) #14 THHN <br />(1) #14 THHN EGC <br />MODEL: <br />LOCATION: <br />FIRST ALERT - HD6135FB <br />ON CEILING DIRECTLY <br />ABOVE ESS ENCLOSURE <br />B <br />JUNCTION BOX, <br />NEMA-3R <br />THWN-2 <br />EGC: THWN-2 1 <br />2B <br />3 <br />#10 <br />#10 EMT 3/4" <br />#10 <br />ROOFTOP <br />ARRAY WIRING A <br />DC <br />AC Branch Circuit #1AC10 AC MODULES <br />H <br />(E) UTILITY <br />BIDIRECTIONAL <br />METER #: <br />222013-153384 <br />EXISTING <br />GROUND <br />THWN-2 <br />EGC: THWN-2 1 <br />3 EMT#6 <br />#10 3/4" <br />MI <br />D <br />ETHERNET <br />CONNECTION <br />TO DSL/CABLE <br />MODEM <br />CA <br />T <br />5 <br />e <br />PVS6 <br />BACKUP BUS (200A MAX) <br /> (N) HUB+ <br />200A, 120/240 V, NEMA-3R <br />MODEL: <br />GE <br />N <br />E <br />R <br />A <br />T <br />I <br />O <br />N <br /> <br />B <br />U <br />S <br />(1 <br />2 <br />5 <br />A <br /> <br />M <br />A <br />X <br />) <br />10 <br />YES <br />LOCATION: <br />SV-HUB-01-C <br />15A, 2P <br />C <br />C <br />OUTSIDE <br />MLO <br />BOTTOM FED <br />MCB <br />GND <br />INCOMING SOURCE FEED <br /> , 120/240 V, 1 PH, 3 W <br />LOCATION: <br />MANUF: <br />GND <br />200A, 2P <br />60A, 2P <br />225A <br />EXTERIOR WALL <br />SQUARE D <br />(E) MAIN SERVICE PANEL <br />SUNPOWER AC MODULES <br />INTERGRATED WITH MICROINVERTER <br />1 <br />ACMSOLAR AC MODULE / BRANCH 1. DC CIRCUIT IS ISOLATED AND INSULATED <br />FROM GROUND AND MEETS THE REQUIREMENT <br />OF NEC 690.35. <br />2. SUNPOWER PROVIDED CABLES COMES WITH <br />TWO (2) #12 AWG WIRE AND THIS IS BY <br />DESIGN. NEUTRAL AND ADDITIONAL GROUND <br />WIRE IS NOT REQUIRED FOR PROVIDED <br />TRUNK AND EXTENSION CABLES. <br />3. SUNPOWER AC MODULES HAVE BEEN TESTED <br />AND CERTIFIED TO UL 2703 FOR INTEGRATED <br />GROUNDING AND HENCE A SEPARATE GROUND <br />WIRE IS NOT REQUIRED WITHIN THE ARRAY. <br />4. USE ROW-TO-ROW GROUNDING CLIP <br />PROVIDED TO GROUND ROWS OF MODULE. <br />BOND SUB-ARRAYS BY RUNNING #6 AWG <br />BARE CU WIRE AND GROUND LUGS AT A <br />SINGLE POINT ON EACH SUB-ARRAY AND THEN <br />TO THE JUNCTION BOX. REFER TO PVE-4 FOR <br />ADDITIONAL DETAILS. <br />1. PROPER LISTING EXPECTED FOR CONDITIONS <br />OF USE ON ALL LUGS, FITTINGS, CRIMPS, ETC. <br />2. ALL CONDUIT BEND RADII TO CONFORM TO <br />THE NEC MINIMUM BEND RADII <br />REQUIREMENTS. <br />3. MINIMUM CLEARANCE SHALL BE MAINTAINED <br />PER NEC FOR ALL NEW EQUIPMENT TO BE <br />INSTALLED. <br />4. EXISTING GROUNDING ELECTRODE SYSTEM <br />MUST MEET NEC AND LOCAL UTILITY <br />REQUIREMENTS. <br />5. COPPER CONDUCTORS SHALL BE USED <br />UNLESS SPECIFIED. <br />6. TYPE NM (ROMEX) CONDUCTORS ARE <br />ALLOWED FOR INTERNAL AND ATTIC RUNS <br />AND SHALL BE INSTALLED MEETING NEC <br />REQUIREMENTS. <br />7. IF MAIN SERVICE PANEL IS TO BE UPGRADED, <br />IT WILL BE PERMITTED AND INSTALLED BY <br />3RD PARTY. <br />8. AC WIRING SHALL UPSIZE IF VOLTAGE DROP <br />EXCEEDS 2%. <br />9. RUN CONDUCTORS IN EXISTING CONDUIT <br />WHEN AVAILABLE PROVIDED IT HAS NO <br />OTHER CONDUCTORS RUNNING THROUGH IT. <br />10. EQUIVALENT SPECIFICATION ON CABLES AND <br />ELECTRICAL EQUIPMENT SPECIFIED ARE <br />ACCEPTABLE. <br />11. AS DC POWER IS INTERNAL TO THE MODULE, <br />GROUNDING ELECTRODE CONDUCTOR (GEC) <br />FOR THE MODULE OR ARRAY IS NOT <br />REQUIRED. <br />AC MODULES NOTESELECTRICAL NOTES <br />PV CERTIFICATIONS AND COMPLIANCE <br />x UL 1741 / IEEE-1547 <br />x UL 1741 AC MODULE (TYPE 2 FIRE RATED) <br />x UL 62109-1 / IEC 62109-2 <br />x UL LISTED PV RAPID SHUTDOWN EQUIPMENT <br />ENABLES INSTALLATION IN ACCORDANCE WITH: <br />x NEC 690.6 (AC MODULE) <br />x NEC 690.12 RAPID SHUTDOWN (INSIDE AND <br />OUTSIDE THE ARRAY) <br />x NEC 690.15 AC CONNECTORS, 690.33(A)–(E)(1) <br />SUNPOWER PROVIDED AC MODULES EXTENSION <br />CABLE, LISTED AS AN ASSEMBLY <br />MODEL: SPR-M-435-H-AC (240) | QTY: 10 <br />MODEL: SPR-M-435-H-AC (240) [SI] | QTY: 10 <br />NO <br />20A, 2P <br />6 <br />YES <br />YES <br />6.5 kWh <br />BATTERY <br />6.5 kWh <br />BATTERY <br />INVERTER <br />DC <br />AC <br />5ENERGY STORAGE SYSTEM <br />MODEL: <br />13 kWh, 6.8 kW SUNVAULT <br />125A, 2P <br />125A, 2P <br />(3) #8 THWN <br />(1) #10 THWN EGC <br />(3) #12 COMM. CABLES <br />40A, 2P <br />SV-BASE13-12-A <br />MLO <br />TO <br />(E)LOADS <br /> (N) LOAD CENTER - BACKUP <br /> MIN., 120/240 V, <br />M.L.O, NEMA-3R <br />LOCATION: <br />11 <br />THWN-2 <br />EGC: THWN-2 1 <br />3 EMT <br />TO <br />(E)LOADS <br />#10 <br />#8 3/4"D <br />D <br />OUTSIDE <br />100A <br />50A, 2P <br />30A, 2P <br />40A, 2POVEN <br />AC <br />SUBFEED BRANCH <br />BREAKER: TYPE HOM <br />INSTALL A SECOND SET OF <br />CONSUMPTION CTS IN PARALLEL <br />AND BUNDLE THE REMAINING <br />LOADS IN THE MSP. <br />YES <br />PROJECT <br />INSTALLER <br />1 <br />4 <br /> <br />1 <br /> <br />4 <br /> <br /> <br /> <br />H <br /> <br />A <br /> <br />R <br /> <br />B <br /> <br />O <br /> <br />U <br /> <br />R <br /> <br /> <br />W <br /> <br />A <br /> <br />Y <br /> <br /> <br />S <br /> <br />O <br /> <br />U <br /> <br />T <br /> <br />H <br />R <br />I <br /> <br />C <br /> <br />H <br /> <br />M <br /> <br />O <br /> <br />N <br /> <br />D <br /> <br />, <br /> <br /> <br />C <br /> <br />A <br /> <br /> <br /> <br /> <br />9 <br /> <br />4 <br /> <br />8 <br /> <br />0 <br /> <br />4 <br />( <br />5 <br /> <br />1 <br /> <br />0 <br /> <br />) <br /> <br /> <br />5 <br /> <br />4 <br /> <br />0 <br /> <br />- <br /> <br />0 <br /> <br />5 <br /> <br />5 <br /> <br />0 <br />C <br />O <br /> <br />R <br /> <br />P <br /> <br />O <br /> <br />R <br /> <br />A <br /> <br />T <br /> <br />I <br /> <br />O <br /> <br />N <br /> <br />, <br /> <br /> <br /> <br /> <br />S <br /> <br />Y <br /> <br />S <br /> <br />T <br /> <br />E <br /> <br />M <br /> <br />S <br />R E V I S I O N S <br />SO <br />L <br />A <br />R <br /> <br />I <br />N <br />D <br />I <br />V <br />I <br />D <br />U <br />A <br />L <br /> <br />P <br />E <br />R <br />M <br />I <br />T <br /> <br />P <br />A <br />C <br />K <br />A <br />G <br />E <br />GR <br />I <br />D <br />- <br />T <br />I <br />E <br />D <br /> <br />P <br />H <br />O <br />T <br />O <br />V <br />O <br />L <br />T <br />A <br />I <br />C <br /> <br />S <br />Y <br />S <br />T <br />E <br />M <br />REV DESCRIPTION DATE DB <br />DRAWN BY: <br />DATE DRAWN <br />SCALE <br />1 AHJ REDLINE 05/07/23 IA <br />LU <br />I <br />S <br />A <br /> <br />S <br />A <br />N <br />C <br />H <br />E <br />Z <br />14 <br />0 <br />2 <br /> <br />M <br />E <br />R <br />I <br />D <br />A <br />Y <br /> <br />L <br />N <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br />L <br />I <br />F <br />O <br />R <br />N <br />I <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />RP-377049 <br />4. <br />3 <br />5 <br /> <br />k <br />W <br />SPRI - ANAHEIM <br />01-17-2023 <br />I. Atienza <br />IAN ATIENZA <br />(N <br />) <br /> <br />1 <br />3 <br /> <br />k <br />W <br />h <br /> <br />S <br />U <br />N <br />V <br />A <br />U <br />L <br />T <br /> <br />E <br />N <br />E <br />R <br />G <br />Y <br /> <br />S <br />T <br />O <br />R <br />A <br />G <br />E <br /> <br />S <br />Y <br />S <br />T <br />E <br />M <br />SHEET <br />NTS <br />EL <br />E <br />C <br />T <br />R <br />I <br />C <br />A <br />L <br /> <br />S <br />I <br />N <br />G <br />L <br />E <br />- <br />L <br />I <br />N <br />E <br /> <br />D <br />I <br />A <br />G <br />R <br />A <br />M <br />& <br />S <br />P <br />E <br />C <br />I <br />F <br />I <br />C <br />A <br />T <br />I <br />O <br />N <br />S <br />PVE-1 <br />1402 W Meriday Ln - <br />201816051/10/2024
The URL can be used to link to this page
Your browser does not support the video tag.