Laserfiche WebLink
(1) The IQ8H-208 variant will be operating in grid-tied mode only at 208V AC. (2) No enforced DC/AC ratio. See <br />the compatibility calculator at https://link.enphase.com/module-compatibility (3) Maximum continuous input <br />DC current is 10.6A (4) Nominal voltage range can be extended beyond nominal if required by the utility. (5) <br />Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. <br />IQ8 Series Microinverters <br />INPUT DATA (DC)IQ8-60-2-US IQ8PLUS-72-2-US IQ8M-72-2-US IQ8A-72-2-US IQ8H-240-72-2-US IQ8H-208-72-2-US1 <br />Commonly used module pairings2 W 235 – 350 235 – 440 260 – 460 295 – 500 320 – 540+ 295 – 500+ <br />Module compatibility 60-cell/120 half-cell 60-cell/120 half-cell, 66-cell/132 half-cell and 72-cell/144 half-cell <br />MPPT voltage range V 27 – 37 29 – 45 33 – 45 36 – 45 38 – 45 38 – 45 <br />Operating range V 25 – 48 25 – 58 <br />Min/max start voltage V 30 / 48 30 / 58 <br />Max input DC voltage V 50 60 <br />Max DC current3 [module Isc]A 15 <br />Overvoltage class DC port II <br />DC port backfeed current mA 0 <br />PV array configuration 1x1 Ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit <br />OUTPUT DATA (AC)IQ8-60-2-US IQ8PLUS-72-2-US IQ8M-72-2-US IQ8A-72-2-US IQ8H-240-72-2-US IQ8H-208-72-2-US1 <br />Peak output power VA 245 300 330 366 384 366 <br />Max continuous output power VA 240 290 325 349 380 360 <br />Nominal (L-L) voltage/range4 V 240 / 211 – 264 208 / 183 – 250 <br />Max continuous output current A 1.0 1.21 1.35 1.45 1.58 1.73 <br />Nominal frequency Hz 60 <br />Extended frequency range Hz 50 – 68 <br />AC short circuit fault current over <br />3 cycles Arms 2 4.4 <br />Max units per 20 A (L-L) branch circuit5 16 13 11 11 10 9 <br />Total harmonic distortion <5% <br />Overvoltage class AC port III <br />AC port backfeed current mA 30 <br />Power factor setting 1.0 <br />Grid-tied power factor (adjustable)0.85 leading – 0.85 lagging <br />Peak efficiency %97.5 97.6 97.6 97.6 97.6 97.4 <br />CEC weighted efficiency %97 97 97 97.5 97 97 <br />Night-time power consumption mW 60 <br />MECHANICAL DATA <br />Ambient temperature range -40ºC to +60ºC (-40ºF to +140ºF) <br />Relative humidity range 4% to 100% (condensing) <br />DC Connector type MC4 <br />Dimensions (HxWxD)212 mm (8.3”) x 175 mm (6.9”) x 30.2 mm (1.2”) <br />Weight 1.08 kg (2.38 lbs) <br />Cooling Natural convection – no fans <br />Approved for wet locations Yes <br />Pollution degree PD3 <br />Enclosure Class II double-insulated, corrosion resistant polymeric enclosure <br />Environ. category / UV exposure rating NEMA Type 6 / outdoor <br />COMPLIANCE <br />Certifications <br />CA Rule 21 (UL 1741-SA), UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 <br />This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section <br />690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according to <br />manufacturer’s instructions. <br />IQ8SE-DS-0001-01-EN-US-2022-03-17 <br />1338 N Custer St <br />05/01/23