Laserfiche WebLink
Check attachment of Support to Existing Structure for Wind Uplift - Cont'd <br />Note: Section 2.4.1 of ASCE 7-22, Basic Load Combinations for Allowable Stress <br />Design. Note: Applicable Load Combination #5 (D + 0.6W) <br />Dead Load = 3.0 psf <br />Wind Load = 30.4 psf <br />Design (Factored) Load at each support: <br />3 psf + (0.6 x 30.4 psf) = 21.24 psf <br />where: <br />Y = Distance between 2 lag screws <br />= 1" <br />Y' = Moment arm to 1st lag screw <br />= 4.4" <br />Moment due to Load = (21.24 psf x 13.8 sq. ft.) x 4.4" inches <br />= 1,290 in-lb <br />Load to lag screw = 1,290 in-lb / 1 in <br />= 1,290 lbs <br />Determine allowable load per 5/16" lag screw w/ 3.25" embedment into wood below <br />according to the 2018 NDS. <br />W ' = W x Cd x Ct Table 10.3.1 2018 NDS <br />where <br />W = 266 lbs / in. of embedment per Table 12.2a <br />Cd = 1.6 per Table 2.3.2 of 2018 NDS <br />Ct = 1.0 per Table 10.3.4 of 2018 NDS <br />W ' = 266 lbs/ in. x 3.25 in. x 1.6 x 1.0 = 1,383 lbs > 1,290 lbs OK <br />Sht # 5 of 7 <br />2023-2182 Tenco Solar Naser Kianfard April 1, 2023 <br /> Loyd W. Martin Professional Engineer, Inc. <br />9924 Universal Boulevard #224-406 Orlando, FL 32819 Tel:1.310.464.1804 <br /> Email: loydwmartin@gmail.com www.loydwmartin.com <br />Use Support connected to 2x Min. Roof Member w/ <br />(2) 5/16" x 3.5" lag screws per connection minimum. <br />1338 N Custer St <br />05/01/23