Laserfiche WebLink
Wyssling Consulting <br />76 N. Meadowbrook Drive <br />Alpine, UT 84004 <br />(201) 874-3483 <br />swyssling@wysslingconsulting.com <br />V =95 Basic Wind Speed Devereaux Residence <br />Exposure C ASCE 7-16, Section 26.7 1417 S Broadway <br />Kz =0.85 Velocity Pressure Coefficient, ASCE 7-16, Figure 26.10-1 Santa Ana, CA <br />Kzt =1 Topographic Factor, ASCE 7-16, Section 26.8.2 <br />Kd =0.85 Directionality Factor, ASCE 7-16, Section 26.6 <br />Ke =0.824 Ground Elevation Factor, ASCE 7-16, Section 26.9 <br />qh =13.8 psf qh = 0.00256KzKztKdKeV2 (ASCE 7-16 Eq. 26.10-1) <br />Roof Angle =0 deg <br />Roof Type Gable <br />sanchor =48 in Horizontal spacing of roof anchors <br />Atrib =6.56 sf Panel Area tributary to each roof anchor <br />GCp External Pressure Coefficient, ASCE 7-16, Figure 30.3-2 <br />Roof Zone Zone 1 1'Zone 2 Zone 3 <br />-1.70 -0.90 -2.30 -3.20 <br />ga =0.80 Pressure Equalization Factor, ASCE 7-16 Figure 29.4.-8 <br />gE =1.00 Edge Array Factor, ASCE 29.4.3 edges < 0.5*building height, and panel spacing < 4ft. <br />pnet = qhGCpgEga =Design Wind Pressure, ASCE 7-16, Equation 29.4-7 <br />Roof Zone 1 1'Zone 2 Zone 3 <br />-19 psf -10 psf -25 psf -35 psf Min Pressure = -16 psf <br />Use 19 psf Use 16 psf Use 25 psf Use 35 psf ULTIMATE <br />x 0.6 =16 psf 16 psf 16 psf 21 psf ALLOWABLE <br />Connection to Existing Roof Framing <br />F.S. =1 Additional Factor of Safety applied to withdrawl force, if desired <br />Atrib =6.6 ft2 <br />DLpanel =5 psf <br />Roof Zone 1 1'Zone 2 Zone 3 <br />Wuplift =19 psf 16 psf 25 psf 35 psf <br />Plag = F.S. x Atrib x (0.6D - 0.6W) =Withdrawl force for each roof anchor <br />Roof Zone 1 1'Zone 2 Zone 3 <br />-54.6 lbs -43.9 lbs -80.6 lbs -119.6 lbs <br />Connection Capacity <br />db =5/16 in Lag Screw diameter <br />Dpen =2 1/2 in Lag Screw penetration into existing framing member <br />No. of Screws 1 Screws per Connection <br />Species of wood framing <br />CD =1.6 Load Duration Factor for Wind Loading, NDS Table 2.3.2 <br />Ct =0.7 Temperature Factor, NDS Table 10.3.4 <br />W =266 lb/in Withdrawl Capacity, NDS Equation 11.2-1 <br />W' = CD x Ct x W =298 lb/in Adjusted withdrawl value <br />Pallow = Dpen x W' =745 lbs <br />Roof Zone 1 1'Zone 2 Zone 3 <br />DEMAND =55 lbs 44 lbs 81 lbs 120 lbs <br />CAPACITY =745 lbs 745 lbs 745 lbs 745 lbs <br />up to72in ok up to72in ok up to72in ok up to72in ok <br />Douglas Fir-Larch <br />Wind Uplift <br />Rooftop Solar Panels Parallel to Roof Surface <br />ASCE 7-16, Section 29.4.4 <br />This analysis calculates the <br />capacity of the lag screws <br />only. For capacity of the <br />complete mounting system, <br />please see manufacturer's <br />recommendations. <br />Signed 6-1-22 <br />1417 S Broadway <br />9/19/2024