My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1506 E Clemensen Ave & #2 - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Clemensen Ave
>
1506 E Clemensen Ave Unit# 2
>
1506 E Clemensen Ave & #2 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2025 2:21:26 PM
Creation date
6/1/2025 11:58:05 AM
Metadata
Fields
Template:
Plan
Permit Number
101119244
Full Address
1506 E Clemensen Ave Unit# 2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
106
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
4 <br />C <br />SA <br />3S <br />D <br />SA <br />CO <br />N5 <br />(N <br />) <br />5 <br />/ <br />8 <br />" <br /> <br />G <br />Y <br />P <br />S <br />U <br />M <br /> <br />B <br />O <br />A <br />R <br />D <br /> <br />T <br />Y <br />P <br />E <br /> <br />" <br />X <br />" <br />A-7 <br />1 <br />GFCI <br />160 CFM MIN <br />NON-RECIRCULING <br />EXHAUST FAN TO <br />OUTSIDE <br />12' - 3" <br />10 <br />' <br /> <br />- <br /> <br />0 <br />" <br />5' <br /> <br />- <br /> <br />0 <br />" <br />16 <br />' <br /> <br />- <br /> <br />5 <br />" <br />12' - 0" <br />10 <br />' <br /> <br />- <br /> <br />0 <br />" <br />REF <br />GREAT ROOM <br />300 SQ.FT. <br />CL <br />BATHROOM <br />BEDROOM <br />120 SQ.FT. MASTER BEDROOM <br />122.5 SQ.FT. <br />BATHROOM <br />CL 2' - 0" <br />5' <br /> <br />- <br /> <br />0 <br />" <br />13' - 7"11' - 0"11' - 10" <br />25 <br />' <br /> <br />- <br /> <br />0 <br />" <br />36' - 4" <br />9' <br /> <br />- <br /> <br />9 <br />" <br />3' <br /> <br />- <br /> <br />1 <br />1 <br />" <br />4' <br /> <br />- <br /> <br />9 <br />" <br />8' - 3" <br />2' - 0"8' - 0" <br />2' <br /> <br />- <br /> <br />0 <br />" <br />8' - 0" <br />3' - 0" 15"min <br />B <br />1 <br />2 <br />22 2 <br />2 <br />3 <br />5' - 7"5 <br />3 <br />3 <br />A <br />C <br />D <br />W D <br />3' - 0"5' - 0"3' - 0" <br />16 <br />' <br /> <br />- <br /> <br />3 <br />" <br />10' - 10" <br />26' - 9" <br />A-7 <br />3 <br />1.5" <br />MAXø 2' - 6" MIN15"MIN <br />15"MIN <br />24 <br />" <br />M <br />I <br />N <br />1.5" <br />MAX <br />CONCRETE <br />LANDING <br />SA <br />SA <br />CO <br />A-7 <br />2 <br />15"min <br />24 <br />" <br />m <br />i <br />n <br />GFCI <br />GFCI GFCI GFCI <br />GFCI <br />GFCI <br />GFCI <br />GFCI <br />GFCI <br />GFCI <br />GFCI <br />GFCI GFCI <br />GFCI <br />WP/GFCI <br />7.75" <br />MAX <br />S <br />D <br />D <br />S 3 <br />D3D <br />S <br />D <br />F <br />F <br />S <br />S <br />D <br />S <br />N1 <br />N2 <br />EGRESS <br />N3 <br />N4 <br />N6 <br />N9 <br />N10 <br />N8 <br />N11 <br />- <br />--- <br />A-A <br />A-7 <br />INDOOR AIR QUALITY <br />(IAQ) FAN-45 CFM MIN <br />3' <br /> <br />- <br /> <br />0 <br />" <br />3'-0" MIN <br />4' - 0" <br />3' OVERHANG <br />5' - 0" <br />PORCH <br />(N)5/8" GYPSUM BOARD TYPE "X" <br />A-7 <br />4,5 <br />A-7 <br />4 <br />36" MIN <br />TE <br />M <br />P <br />E <br />R <br />E <br />D <br />ELECTRIC RANGE: <br />NO GAS HOOK UP AT STOVE. <br />VS <br />A-7 <br />7 <br />A-7 <br />7 <br />N7 <br />Scale <br />Project number <br />Date <br />Drawn by <br />Owner <br />Project Address <br />Phone <br />1/4" = 1'-0" <br />A-5 <br />FLOOR PLAN <br />37-23 <br />NANCY CALTAGIRONE <br />08/2024 <br />JENNY PARADA <br />Main House: <br />1506 E CLEMENSEN AVE <br />SANTA ANA, CA 92705 <br />ADU: <br />1506 E CLEMENSEN AVE # 2 <br />SANTA ANA, CA 92705 <br />613 S EASTBURY AVE, <br />COVINA CA 91723 <br />DOOR SCHEDULE <br /># <br />HEIGHT THICKNESSWIDTH <br />SIZE NOTES <br />QUANTITY <br />WINDOW SCHEDULE <br />WIDTH#TYPEHEIGHT NOTES <br />4'-0" <br />5'-0" <br />A <br />B <br />4'-0" <br />4'-0" <br />SLIDING <br />5'-0" <br />1 3/8" <br />1 3/8"3'-0"6'-8"1 <br />2 <br />3 <br />ENTRY DOOR <br />DOUBLE FRENCH DOOR - TEMPERED <br />DOUBLE GLAZING <br />DOUBLE GLAZING-EGRESS <br />1 <br />1 <br />1 3/8" <br />C <br />N1 <br />N2 <br />N3 <br />N4 <br />SLEEPING ROOMS MUST HAVE A WINDOW OR <br />EXTERIOR DOOR FOR AN EMERGENCY EXIT, SILL <br />HEIGHT NOT MORE THAN 44 INCHES ABOVE THE <br />FLOOR, 5.7 SQ. FT. OF OPENABLE AREA, 24 INCHES <br />CLEAR OPENING HEIGHT, 20 INCHES CLEAR <br />OPENING WIDTH AND SHALL OPEN DIRECTLY INTO <br />A PUBLIC STREET, ALLEY, YARD, OR EXIT COURT. <br />PROVIDE 15" MINIMUM BETWEEN THE CENTER OF <br />WATER CLOSET TO ANY SIDE WALL. <br />PROVIDE 24" CLEAR SPACE IN FRONT OF ANY <br />WATER CLOSET. <br />BATHROOMS, WATER CLOSET COMPARTMENTS AND <br />OTHER SIMILAR ROOMS SHALL BE PROVIDED WITH <br />MECHANICAL VENTILATION CAPABLE OF 50 CFM MIN <br />EXHAUSTED DIRECTLY TO THE OUTSIDE WITH <br />HUMIDITY CONTROL. <br />KEY NOTES <br />S <br />DIMMER <br />(PROVIDE VACANCY SENSOR AT BATHROOMS) <br />GFIT <br />PROVIDE EXHAUST FAN OF 4 AIR CHANGES <br />PER HOUR MINIMUM, WITH HUMIDITY <br />CONTROL SENSOR. 50 CFM MIN <br />"FANS SHALL BE ENERGY STAR COMPLIANT <br />CONTROLLED BY HUMIDISTAT AND DUCTED <br />TO TERMINATE TO THE OUTSIDE OF THE <br />BUILDING" <br />LEGEND <br />SMOKE ALARM TO BE HARD WIRED WITH <br />BATTERY BACK UP AND INTERCONNECTED <br />TO SOUND AT THE SAME TIME <br />COMBO SMOKE AND CARBON MONOXIDE <br />ALARM TO BE HARD WIRED WITH BATTERY <br />BACK UP AND INTERCONNECTED TO <br />SOUND AT THE SAME TIME <br />SA <br />SA <br />CO <br />GAS <br />SWITCH <br />LIGHT FIXTURE WITH PHOTOCONTROL & <br />MOTION SENSOR MS <br />EFF <br />LIGHT HIGH EFFICACY <br />D <br />NEW WOOD STUD <br />FRAMING <br />2X4 OR 2X6 AT 16"O.C. <br />NEW 1-HR FIRE RATED WALL <br />OUTLET GROUND FAULT INTERRUPTER <br />TAMPER PROOF, WATER RESISTANT WITH <br />BUBLE COVER <br />OUTLET AFCI <br />N5 ATTIC ACCESS WITH A MINIMUM SIZE OF 22 X 30 <br />INCHES UNLESS THE MAXIMUM VERTICAL HEADROOM <br />HEIGHT IN THE ATTIC IS LESS THAN 30 INCHES. WHERE <br />MECHANICAL EQUIPMENT IS INSTALLED IN THE ATTIC <br />THE MINIMUM DIMENSIONS ARE 30 INCHES X 30 INCHES <br />AND AT LEAST AS LARGE AS THE LARGEST <br />COMPONENT OF THE APPLIANCE. <br />U-FACTOR <br />2'-0" 2'-0"SLIDING 2 <br />INTERIOR COLONISH,PRE-HUNG DOOR2'-8"6'-8" <br />PROPOSED FLOOR PLAN <br />ESC 1/4"=1'-0" <br />4 <br />PATIO DOOR <br />1 3/8" <br />OBSCURE TEMPERED GLASS <br />N6 SHOWERS AND SHOWER-TUBS SHALL BE PROVIDED <br />WITH INDIVIDUAL CONTROL VALVES OF THE PRESSURE <br />BALANCE, THERMOSTATIC, OR COMBINATION <br />PRESSURE BALANCE/THEROSTATIC MIXING VALVE <br />TYPE THAT PROVIDE SCALD AND THERMAL SHOCK <br />PROTECTION. <br />PROVIDE SMOKE ALARMS IN EACH NEW <br />AND EXISTING SLEEPING ROOM AND AT A <br />POINT ON THE CEILING OR WALL OUTSIDE <br />OF EACH SEPARATE SLEEPING AREA IN THE <br />IMMEDIATE VICINITY OF BEDROOMS. <br />IN NEW CONSTRUCTION, THE REQUIRED <br />SMOKE ALARMS SHALL RCEIVE THEIR <br />PRIMARY POWER FROM THE BUILDING <br />WIRING AND SHALL BE EQUIPPEED WITH A <br />BATTERY BACKUP. SMOKE ALARMS MAY BE <br />SOLELY BATTERY OPERATED WHEN <br />INSTALLED IN EXISTITNG SLEEPING ROOMS <br />AND HALLWAYS. <br />N7 NEEA HEAT PUMP WATER HEATER <br />50 GAL MIN <br />N8 CLOTHER DRYER MOISTURE EXHAUST DUCTS SHALL <br />TERMINATE OUTSIDE OF THE BUILDING AND HAVE A <br />BACK-DRAFT DAMPER. EXHAUST DUCT IS LIMITED TO <br />14 FEET WITH 2 ELBOWS. THIS SHALL BE REDUCED 2 <br />FEET FOR EVERY ELBOW IN EXCESS OF 2. MINIMUM 4 <br />INCH DIAMETER, SMOOTH, METAL DUCT. <br />SEE DETAIL 6, SHEET A-7 <br />N9 SAFETY GLAZING SHALL BE PROVIDED IN SHOWER <br />AND TUB ENCLOSURES (LESS THAN 60" ABOVE <br />STANDING SURFACE & 60" HORIZONTALLY FROM EDGE <br />OF BATHTUB AND SHOWER) <br />N10 SHOWERS AND WALLS ABOVE BATHTUBS WITH <br />SHOWER HEADS SHALL BE FINISHED WITH A SMOOTH, <br />NONABSORBENT SURFACE TO A HEIGHT NOT LESS <br />THAN 72 INCH ABOVE THE DRAIN INLET. <br />6'-0" <br />MIRROR WARDROBE DOOR6'-8" <br />6'-8" <br />6'-8"5 2'-0"1 3/8" <br />BI-FOLD DOOR6'-8"6 6'-0"1 3/8" <br />3'-0"D 3'-0"DOUBLE GLAZING1 <br />SLIDING <br />SLIDING <br />ADU <br />PROVIDE 100 CFM <br />NON-RECIRCULING EXHAUST FAN <br />N11 <br />No. Description Date <br />1 Revision 1 Date 1 <br />714-997-0313 <br />1) At least one bathroom on the entry level shall be provided with reinforcement for grab bars, <br />where there is no bathroom on the entry level, at least one bathroom on the second or third <br />floor of the dwelling shall comply with CRC R327.1.1. (SEE DETAIL AND NOTES ON THIS SHEET) <br />2) Electrical receptacle outlets, switches and controls shall be located no more than 48” <br />measured from the top of the outlet box and not less than 15” measured from the bottom <br />of the outlet box above the finish floor. CRC R327.1.2. <br />3) Doorbell buttons shall not be installed more than 48” above exterior floor or landing. CRC <br />R327.1.4. <br />AGING -IN-PLACE AND FALL PREVENTION NOTES (CRC R327): <br />GRAB BARS DETAILS <br />At least one bathroom on the entry level shall be provided with reinforcement installed in accordance with this <br />section. (CRC R327.1.1) <br />a. Reinforcement shall be solid lumber or other construction materials approved by the enforcing agency. <br />b. Reinforcement shall not be less than 2 by 8 inch nominal lumber. <br />(1-1/2 inch by 7-1/4 inch actual dimension) or other construction material providing equal height and load <br />capacity. Reinforcement shall be located between 32 inches (812.8 mm) and 39-1/4 inches (997 mm) above the <br />finished floor) flush with the wall framing. <br />c. Water closet reinforcement shall be installed on both side walls of the fixture, or one side wall and the back wall. <br />d. Shower reinforcement shall be continuous where wall framing is provided. <br />e. Bathtub and combination bathtub/shower reinforcement shall be continuous on each end of the bathtub and the <br />back wall. Additionally, back wall reinforcement for a lower grab bar shall be provided with the bottom edge <br />located no more than 6 inches (152.4 mm) above the bathtub rim. <br />SEE NOTE # 2 ON <br />AGING-IN-PLACE <br />NOTES <br />SHGC <br />0.3 0.23 <br />0.3 0.23 <br />0.3 0.23 <br />0.3 0.23 <br />VS <br />U-FACTOR SHGC <br />0.3 0.23 <br />0.3 0.23 <br />- - <br />- - <br />- - <br />- - <br />1506 E Clemensen Ave & <br />#212/12/2024
The URL can be used to link to this page
Your browser does not support the video tag.