Laserfiche WebLink
36 <br />6 <br />2 <br />5 <br /> <br />K <br />E <br />V <br />I <br />N <br /> <br />R <br />D <br />. <br /> <br />S <br />T <br />E <br />. <br /> <br />1 <br />4 <br />7 <br />/ <br />1 <br />4 <br />8 <br />WI <br />L <br />D <br />O <br />M <br />A <br />R <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />5 <br />9 <br />5 <br />95 <br />1 <br />- <br />6 <br />9 <br />6 <br />- <br />9 <br />4 <br />0 <br />0 <br />CH <br />A <br />R <br />L <br />E <br />S <br /> <br />M <br />O <br />R <br />R <br />I <br />S <br />O <br />N <br />Li <br />c <br />. <br /> <br />N <br />o <br />. <br /> <br />1 <br />0 <br />9 <br />3 <br />1 <br />5 <br />2 <br />Sheet: <br />Title: <br />Project #: <br />Date/Time: <br />CUSTOMER: <br />GENERAL NOTES: <br />PLAN DIRECTORY: <br />ELECTRICAL NOTES: <br />CONTRACTOR:PROJECT SCOPE: <br />PRECIS SOLAR <br />36625 KEVIN RD. STE. 147/148 <br />WILDOMAR, CA 92595 <br />951-696-9400 <br />CHARLES MORRISON <br />Lic. No. 1093152 <br />6/6/2023 10:41:31 AM <br />TITLE SHEET <br />Re <br />b <br />e <br />c <br />c <br />a <br />Be <br />n <br />n <br />e <br />t <br />t <br /> <br />15 <br />2 <br />2 <br /> <br />E <br />a <br />s <br />t <br />s <br />i <br />d <br />e <br /> <br />A <br />v <br />e <br />n <br />u <br />e <br />Sa <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br /> <br />T-01 <br />0011 <br />Rebecca Bennett <br />1522 Eastside Avenue <br />Santa Ana, CA 92701 <br />(909)435-1445 <br />Rebecca Bennett <br />(18) <br />(18) 350 <br />350 <br />SHEET #SHEET NAME <br />T-01 TITLE SHEET <br />PV-01 SITE PLAN <br />MD-01 MOUNTING DETAILS <br />E-01 ELECTRICAL SINGLE LINE <br />DP-1 PV SIGNAGE <br />SOLAR INSTALLATION WILL ABIDE BY THE FOLLOWING: <br />OCCUPANCY GROUP R3, CONTRUCTION TYPE VB. <br />THE PROJECT CONSISTS OF: <br /> SUNPOWER SPR-X21- -BLK-E-AC <br />SOLAR MODULES <br /> SUNPOWER SPR-X21- -BLK-E-AC <br />MICRO INVERTERS <br />1. PHOTOVOLTAIC SOLAR MODULES UL 1703; INVERTERS: UL 1741, PHOTOVOLTAIC MODULES ARE TO BE CONSIDERED NON-COMBUSTABLE. <br />2. CONTRACTOR SHALL BE PRESENT DURING ALL INSPECTIONS <br />3. ALL CONSTRUCTION SHALL COMPLY WITH THE 2022 EDITION OF THE CALIFORNIA TITLE 24, INCLUDING BUT NOT LIMITED TO RESIDENTIAL CODE SECTIONS R324,R909 AND R918; 2022 CBC, CRC, CEBC, CMC, CPC, CEC, 2022 CFC <br />4. ALL MODULE AND RACKING GROUNDING LUGS SHALL BE UL 567 APPROVED (ILSCO GBL-4DBT) <br />5.NO SHEET METAL OR TEC SCREWS SHALL BE USED TO GROUND DISCONNECT ENCLOSURES WITH TIN-PLATED ALUMINUM LUGS; PROPER GROUNDING/GROUND BAR KITS WILL BE USED. <br />6.FERROUS METAL RACEWAYS ENCLOSING GEC CONDUCTORS SHALL BE ELECTRICALLY CONTINUOUS OR BONDED <br />7.THE ROOF ACCESS POINT REQUIRING A LADDER SHALL NOT BE LOCATED OVER A WINDOW, DOOR OR LOCATED WHERE IT CONFLICTS WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS <br />8.A LADDER SHALL BE PROVIDED AND SECURED TO THE STRUCTURE AT THE APPROVED ROOF ACCESS POINT PER NOTE 7. ABOVE WITH A CAL OSHA APPROVED DEVICE DURING ALL INSPECTIONS <br />9. EXISTING ROOF AND PLUMBING VENTS SHALL NOT BE OBSTRUCTED BY ARRAY INSTALLATION. PLUMBING VENTS ARE REQUIRED TO BE RE-ROUTED THROUGH ATTIC SPACE AND TERMINATE A MINIMUM OF 6 INCHES ABOVE THE ROOF LINE <br />10. SMOKE ALARMS TO BE INSTALLED OUTSIDE EACH SEPARATE SLEEPING AREA, IN EACH ROOM FOR SLEEPING PURPOSES, IN EACH STORY, INCLUDING BASEMENT CARBON MONOXIDE DETECTORS TO BE INSTALLED AS COMBINATION UNITS WITH SMOKE <br />DETECTORS IN ALL REQUIRED LOCATIONS <br />11. THE BACKFED PV BREAKER(S) AT THE MAIN PANEL WILL BE INSTALLED AT THE OPPOSITE END OF THE BUS BAR FROM THE MAIN BREAKER AND A PERMANENT WARNING LABEL WITH THE FOLLOWING MARKING WILL BE PROVIDED ADJACENT TO THE PV <br />BREAKER(S):"WARNING -POWER SOURCE OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE." <br />1.ALL DISCONNECT SWITCHES SHALL BE WIRED SUCH THAT THE LINE SIDE WILL HAVE LIVE CONDUCTORS WHEN THE SWITCH IS ON THE OPEN POSITION. <br />2.MARKING OF THE “PV SYSTEM DISCONNECT” SHALL BE IN ACCORDANCE WITH CEC. MARKING OF THE “INTERACTIVE SYSTEM POINT OF CONNECTION” SHALL BE IN ACCORDANCE WITH CEC <br />3. ALL EXTERIOR CONDUIT, FITTINGS AND BOXES SHALL BE RAIN TIGHT AND APPROVED FOR USE IN A WET LOCATION. <br />4. PV EQUIPTMENT, SYSTEMS AND ALL ASSOCIATED WIRING AND INTERCONNECTIONS SHALL ONLY BE INSTALLED BY QUALIFIED PERSONS <br />5.PHOTOVOLTAIC SYSTEM CONDUCTORS SHALL BE IDENTIFIED AND GROUPED. THE MEANS OF IDENTIFICATION SHALL BE PERMITTED BY SEPARATE COLOR CODING, MARKING TAPE, TAGGING OR OTHER APPROVED MEANS <br />6.WHERE A UFER CANNOT BE VERIFIED OR IS NOT PRESENT, A GROUNDING ELECTRODE SYSTEM SHALL BE INSTALLED <br />7. ROOF MOUNTED CONDUITS AND RACEWAYS SHALL BE 7/8TH INCH OFF OF THE ROOF DECK OR THE STIPULATIONS OF 310.15(B)(2) SHALL APPLY <br />8.PV MODULES ARE CLASS A FIRE RATED AND ALL EQUIPMENT SHALL BE LISTED AND LABELED BY A NATIONALLY RECOGNIZED TESTING LABORATORY (NRTL) <br />9.ALL EQUIPMENT IS TO BE INSTALLED PER MANUFACTURER SPECIFICATIONS <br />PHOTOVOLTAIC INSTALLATION 6.300 kWpDC / 5.670 kWpAC <br />DESIGN BY: <br />Charles Morrison <br />- B, C10 #1093152 <br />www. Loyd W Martin .com <br />Solar Structures Engineering <br />#2023-4335 Structural Only <br />July 29, 2023 <br />The scope of the plans is for the installation of the solar photovoltaic system only <br />and the approval is subject to compliance with all applicable city and state codes <br />and regulations regarding construction. The approval of the plans does not <br />constitute any certification of the accuracy, completeness, or building permit status <br />of the existing buildings and structures as shown. <br />Bldg# 101116595 <br />Elec# 20180944 <br />Issued 09/11/23 <br />1522 N Eastside Ave <br />09/12/23