Laserfiche WebLink
MIN3' C <br />LR <br />EX. SFD <br />LADDER ACCESS PER CFC <br />TOTAL ROOF AREA: 2,434 Sq.Ft. <br />TOTAL PV AREA: 326 Sq.Ft. <br />PV ARRAY < 33% OF ROOF AREA <br />FIRE SPRINKLER SYSTEM: NO <br />.: 18" RIDGE SETBACK IS OK <br />Ex. P <br />a <br />t <br />io <br />Ex. Driv <br />ew <br />a <br />y <br />Eastsi <br />de Avenue <br />1 2 <br />3 <br />4 <br />5 <br />MIN3' CLR <br />MIN 3' CLR <br />MI <br />N <br /> <br />3 <br />' <br /> <br />C <br />L <br />R <br />MI <br />N <br />3' CLR <br />MIN 3' CLR <br />36 <br />6 <br />2 <br />5 <br /> <br />K <br />E <br />V <br />I <br />N <br /> <br />R <br />D <br />. <br /> <br />S <br />T <br />E <br />. <br /> <br />1 <br />4 <br />7 <br />/ <br />1 <br />4 <br />8 <br />WI <br />L <br />D <br />O <br />M <br />A <br />R <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />5 <br />9 <br />5 <br />95 <br />1 <br />- <br />6 <br />9 <br />6 <br />- <br />9 <br />4 <br />0 <br />0 <br />CH <br />A <br />R <br />L <br />E <br />S <br /> <br />M <br />O <br />R <br />R <br />I <br />S <br />O <br />N <br />Li <br />c <br />. <br /> <br />N <br />o <br />. <br /> <br />1 <br />0 <br />9 <br />3 <br />1 <br />5 <br />2 <br />Sheet: <br />Title: <br />Project #: <br />Date/Time: 6/6/2023 10:41:32 AM <br />SITE PLAN <br />Re <br />b <br />e <br />c <br />c <br />a <br />Be <br />n <br />n <br />e <br />t <br />t <br /> <br />1 <br />5 <br />2 <br />2 <br /> <br />E <br />a <br />s <br />t <br />s <br />i <br />d <br />e <br /> <br />A <br />v <br />e <br />n <br />u <br />e <br /> <br />Sa <br />n <br />t <br />a <br /> <br />An <br />a <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />PV-01 <br />0011 <br />IMPORTANT NOTES: <br />KEY NOTES <br />1. EXISTING UTILITY SERVICE PANEL <br />AND RAPID SHUTDOWN COMPLIANT DISCONNECT <br />* WILL ABIDE BY WORKING CLEARANCES PER CEC 110.26(A)(1) <br />2. PROPOSED LOCATION OF SOLAR LOAD CENTER <br />* WILL ABIDE BY WORKING CLEARANCES PER CEC 110.26(A)(1) <br />3. PROPOSED LOCATION OF INVERTER(S) <br />4. PROPOSED LOCATION OF CONDUIT <br />5. PROPOSED LOCATION OF JUNCTION BOX (UNDER PANEL) <br />A. ALL EXPOSED ROOF WIRING SHALL BE PV WIRE TYPE RATED FOR <br />(90⁰C) WET CONDITIONS. OTHER OUTDOOR WIRING SHALL BE COPPER <br />THWN-2 TYPE RATED FOR (90⁰C) APPLICATIONS IN EMT CONDUIT. <br />B.ALL COMPONENTS ARE UL LISTED AND CEC CERTIFIED WHERE <br />WARRANTED. <br />C.THE SOLAR PV SYSTEM WILL BE INSTALLED IN ACCORDANCE WITH <br />ARTICLE 690 OF THE 2022 CEC AND 2022 CBC. <br />D.WHERE METALLIC CONDUIT CONTAINING DC CONDUCTORS IS USED <br />INSIDE THE BUILDING, IT SHALL BE IDENTIFIED AS “CAUTION: SOLAR <br />CIRCUIT” EVERY 5 FEET. <br />E.A DC DISCONNECTING MEANS SHALL BE INSTALLED AT A READILY <br />ACCESSIBLE LOCATION EITHER OUTSIDE OF A BUILDING OR <br />STRUCTURE OR INSIDE NEAREST TO THE POINT OF ENTRANCE OF <br />THE SYSTEM CONDUCTORS AS PER SECTION 690-14 OF THE CEC. <br />F.HEIGHT OF THE INTEGRATED AC/DC DISCONNECT SHALL NOT <br />EXCEED 6’-7” PER NEC 240.24 <br />G.WORKING CLEARANCE AROUND THE EXISTING ELECTRICAL <br />EQUIPMENT AS WELL AS THE NEW ELECTRICAL EQUIPMENT WILL BE <br />IN ACCORDANCE WITH NEC 1010.26. <br />H.WHERE DC CONDUCTORS ARE RUN INSIDE THE BUILDING (OR <br />ATTIC), THEY SHALL BE CONTAINED IN A METAL RACEWAY. (NEC <br />690.31 E) <br />I. WIRE NUTS ARE NOT ALLOWED ANYWHERE IN THE PV SYSTEM PER <br />INSTALLATION GUIDE AND CEC SECTION 110.3[8]. <br />J. AS PER 705.10 "A PERMANENT PLAQUE OR DIRECTORY, DENOTING <br />ALL ELECTRIC POWER SOURCES ON THE PREMISES, SHALL BE <br />INSTALLED AT EACH SERVICE EQUIPMENT LOCATION AND AT <br />LOCATIONS OF ALL ELECTRIC POWER PRODUCTION SOURCES <br />CAPABLE OF BEING INTERCONNECTED." <br />K. THE GEC/EGC SHALL BE CONTINOUS, OR WHEN SPLICED, THE <br />SPLICE SHALL BE MADE BY IRREVERSIBLE CRIMP. <br />L. INTERIOR CONDUIT TO BE RAN A MIN 18" BELOW ROOF DECKING. <br />M. ALL CONDUITS AND EQUIPMENT SHALL BE PAINTED TO MATCH <br />THE EXISTING BACKGROUND MATERIAL COLOR OF THEIR LOCATION. <br />N. MODULES AND RACKING ARE IN ACCORDANCE WITH UL 1703. (CRC <br />R902.4) <br />DESIGN BY: <br />Charles Morrison <br />- C10 #1093152 <br />www. Loyd W Martin .com <br />Solar Structures Engineering <br />#2023-4335 Structural Only <br />July 29, 2023 <br />NOTE: <br />Engineer of Record assumes that all structural components <br />of the existing building were permitted and met the <br />requirements of the Building Code at the time of <br />construction. Solar Contractor shall field verify that the roof <br />framing is in its existing permitted condition and capable of <br />supporting required live loads. Framing specified on solar <br />plans shall be assumed to be minimum size and spacing, <br />actual framing may be different. <br />1522 N Eastside <br />Ave09/12/23