Bolt Calculation Tool <br />Record ID #: <br />Carrier Site ID: <br />Carrier Site Name: <br />Connection Description: <br />Tension Force: 572.8 lbs <br />Shear Force: 193.8 lbs <br />Governing LC: 38 -- <br />Governing Member: M8 -- <br />Sliding Force: 261.2 lbs <br />Torsional Force: 286.4 lbs-ft <br />Governing LC: 38 -- <br />Governing Member: M8 -- <br />Connection Type: Threaded Rod -- <br />Connection Grade: A307 -- <br />Nominal Diameter: 0.5 in <br /># of Bolts: 2 -- <br />Shear Planes: Single -- <br />Tensile Strength (ɌTn): 6385.4 lbs <br />Shear Strength (ĭVn): 5522.3 lbs <br />Tensile Usage: 9.0% <br />Shear Usage: 3.5% <br />Interaction Check: 0.090 < 1.05 <br />Result: Pass <br />Pretension Standard: TIA-222-H -- <br />Sliding Strength (ɌRns): 4712.4 lbs <br />Slippage Strength (ĭRnr): 1178.1 lbs <br />Sliding Usage: 5.5% <br />Slippage Usage: 24.3% <br />Interaction Check: 0.249 < 1.05 <br />Result: Pass <br />TORSIONAL SLIPPAGE & SLIDING CHECK <br />BOLT PROPERTIES <br />22.102 <br />BOLT CHECK <br />PROJECT DATA <br />LSSNA01229A <br />Saint Anne <br />RRHs to Pipe Connection <br />APPLIED LOADS <br />1344 3%4 S Main <br />St WCC01 - <br />10111364403/23/23