Laserfiche WebLink
SHEET TITLE <br />SHEET NUMBER <br />OWNER <br />PROJECT TITLE <br />JOBSITE ADDRESS <br />GARIBAY <br />RESIDENCE <br />1 401 <br />W SANTA <br />CLARA AVE <br />SANTA ANA, CA <br />92706 <br />CONTRACTOR <br />820 THOMPSON AVE, UNIT 28 <br />GLENDALE CA 91201 <br />PHONE: 818-634-6527 <br />C10 CA LICENSE # 978687 <br />LA POWER CENTER <br />CORPORATION <br />ARMIN GHARIBIAN SAKI, LICENSE HOLDER <br />DATE DESCRIPTION <br />REVISION <br />DATE <br />DRAWN08-18-22 DESIGN <br />REVISION <br />DESIGN BY: LG/SC <br />CAD <br />F O R C A L I I N C . <br />SHELLEY V CALUAG <br />cadforcali@gmail.com <br />323-698-4207 <br />5.600 DC kW <br />5.045 kW CEC-AC Rating <br />MICRO INVERTER SYSTEM <br />E2 <br />ELECTRICAL <br />CALCULATIONS <br />INVERTER SPECIFICATION <br />INVERTER MAKE ENPHASE ENERGY <br />INVERTER MODEL NO. IQ7PLUS-72-2-US (240V) [SI1] <br />MAX INPUT DC VOLTAGE 60 V <br />MAX CONT. OUTPUT POWER 290 VA <br />RECOMMENDED INPUT POWER 235 W - 440 W <br />NOMIMAL AC VOLTAGE/RANGE 240 V/ 211-264 V <br />MAX AC CURRENT 1.21 A <br />AC CONDUCTOR AMPACITY CALCULATIONS - SUM OF CIRCUITS <br />AC COMBINER TO POINT OF CONNECTION <br />A AMBIENT TEMPERATURE ADJUSTMENT <br />EXPOSED CONDUIT 39 CELSIUS <br />TEMPERATURE CORRECTION FACTOR 0.96 CEC TABLE 310.15 (B)(2)(A) <br /># OF CURRENT CARRYING CONDUCTORS 2 (UP TO 8 CONDUCTORS IN ROOF MOUNTED CONDUITS EXPOSED TO SUNLIGHT) <br />CONDUIT FILL CORRECTION 1.00 .80 (FOR 4 TO 6 CONDUCTORS IN CONDUIT) OR 1.00 (FOR 3 OR LESS CONDUCTORS IN CONDUIT) <br />CEC TABLE 310.15 (B)(3)(A) <br />CIRCUIT CONDUCTOR SIZE #10 AWG <br />40 AMPS CEC TABLE 310.15 (B)(16) <br />INVERTER'S MAXIMUM AC OUTPUT CURRENT 1.21 AMPS INVERTER MANUFACTURER SPECIFICATIONS <br />B REQUIRED AC CONDUCTOR AMPACITY 21.17 AMPS REQUIRED CIRCUIT CONDUCTOR AMPACITY = 1.25 X AC MODULE OUTPUT CURRENT X TOTAL # OF AC MODULES <br />C DERATED AMPACITY OF CIRCUIT CONDUCTORS 38.40 AMPS TEMPERATURE CORRECTION X CONDUIT FILL CORRECTION X CIRCUIT CONDUCTOR AMPACITY <br />CEC TABLE 310.15 (B)(2)(A) <br />NOTE: "C" MUST BE GREATER THAN "B" 38.40A > 21.17A = OK <br />LOCATION INFORMATION <br />NEC TABLE 310.15 (B)(2)(a)-TEMP CORRECTION FACTORS <br />HIGH TEMP 34 <br />LOW TEMP 2 <br />VOLTAGE CORRECTION FACTOR -TABLE 690.7(A)1.10 <br />7/8" ABOVE ROOF 67 <br />TEMP CORRECTION FACTOR (ABOVE ROOF)0.58 <br />TEMP CORRECTION FACTOR (INSIDE CONDUIT)0.96 <br />AC CONDUCTOR AMPACITY CALCULATIONS <br />JBOX/COMBINER BOX TO AC COMBINER - PER RANCH CIRCUIT <br />A EXPECTED WIRE TEMPERATURE (FREE AIR)34 CELSIUS <br />310.15(B)(3)(C) RACEWAYS AND CABLES EXPOSED TO SUNLIGHT ON ROOFTOPS. WHERE RACEWAYS OR CABLES <br />ARE EXPOSED TO DIRECT SUNLIGHT ON OR ABOVE ROOFTOPS, RACEWAYS OR CABLES SHALL BE INSTALLED A <br />B SUNLIGHT ON OR ABOVE ROOF 67 CELSIUS WIRING/CONDUIT RACEWAY WILL BE EQUAL TO 7/8'' OR MORE ABOVE THE ROOFTOP PER CEC 310.15(B)(3)(c) <br />TEMPERATURE CORRECTION FACTOR <br />CEC TABLE 310.15 (B)(2)(A)0.96 <br />C # OF CURRENT CARRYING CONDUCTORS 4 (UP TO 8 CONDUCTORS IN ROOF MOUNTED CONDUITS EXPOSED TO SUNLIGHT) <br />D CONDUIT FILL CORRECTION 0.80 .80 (FOR 4 TO 6 CONDUCTORS IN CONDUIT) OR 1.00 (FOR 3 OR LESS CONDUCTORS IN CONDUIT) <br />CEC TABLE 310.15 (B)(3)(A) <br />E CIRCUIT CONDUCTOR SIZE #10 AWG <br />F 35 AMPS CEC TABLE 310.15 (B)(16) <br />G REQUIRED CIRCUIT CONDUCTOR AMPACITY 10.59 AMPS REQUIRED CIRCUIT CONDUCTOR AMPACITY = 1.25 X AC MODULE OUTPUT CURRENT X # OF AC MODULES PER <br />CIRCUIT <br />H DERATED AMPACITY OF CIRCUIT CONDUCTOR 26.88 AMPS TEMPERATURE CORRECTION X CONDUIT FILL CORRECTION X CIRCUIT CONDUCTOR AMPACITY <br />CEC TABLE 310.15 (B)(2)(A) <br />NOTE: "H" MUST BE LARGER THAN "G" 26.88A > 10.59A = OK - CIRCUIT WITH 7 MODULES <br />MODULE SPECIFICATION <br />MANUFACTURER HANHWA Q.CELLS <br />MODEL NO.Q.PEAK DUO BLK <br />ML-G10+400 <br />PEAK POWER 400 W <br />MPP VOLTAGE (VMPP) 37.13 V <br />MPP CURRENT (IMPP) 10.77 A <br />OPEN CIRCUIT VOLTAGE (VOC) 45.30 V <br />SHORT CIRCUIT CURRENT (ISC) 11.14 A <br />1401 W Santa <br />Clara Ave10/31/22