Laserfiche WebLink
SHEET NAME <br />SHEET SIZE <br />SHEET NUMBER <br />ANSI B <br />11" X 17" <br />SIGNATURE WITH SEAL <br />PROJECT NAME & <br />ADDRESS <br />A1.0 <br />DATE: 2/17/2023 <br />1 <br />5 <br />3 <br />5 <br /> <br /> W <br /> <br />P <br />O <br />M <br />O <br />N <br />A <br /> <br />S <br />T <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br />, <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />FE <br />L <br />IP <br />E <br /> <br />E <br />L <br />IZ <br />A <br />L <br />DE <br /> R <br />ES <br />I <br />D <br />E <br />N <br />C <br />E <br />TROY STOKES <br />2491 ALLUVIAL AVE <br />#22 CLOVIS, CA 93611 <br />CONTRACTOR LIC#: #904259 <br />PHONE #: 559-797-2232 <br />GENERAL B,C10-ELECTRICAL <br />DESCRIPTION DATE REV <br />REVISIONS <br />INITIAL DESIGN 2/17/2023 00 <br />SITE PLAN <br />MODULE, ARRAY WEIGHT (LOAD CALC'S) <br />Number of Modules 10 EACH <br />Module Weight 51.6 LBS <br />Total Module (Array) Weight 516.00 LBS <br />Number of Attachment point 23 EACH <br />Mounting System Weight <br />(Per Module)1.5 LBS <br />Mounting System Weight 34.5 LBS <br />Total System Weight <br />(Total Module Weight + Mounting System Weight)550.5 LBS <br />Weight at Each Attachment Point <br />(Array Weight / Number of Attachment Point)22.43 LBS <br />Module Area (76.4"x41.3")21.91 SqFt <br />Total Array Area 219.1 SqFt <br />Distributed Load <br />(Total System Weight / Total Array Area)2.51 Per SqFt <br />Total Roof Area 3555 SqFt <br />EXISTING SOLAR AREA 0 SqFt <br />Total Percentage or Roof Covered <br />Total Array Area / Total Roof Area)*100 6.16 % <br />= ATTACHMENT POINTS <br />= WOOD <br />= RACKING SYSTEM <br />= EXTERIOR RUN <br />= CONDUIT ROOF TOP JUNCTION BOX <br />SYSTEM LEGEND <br />M <br />AC <br />C <br />NEW PHOTOVOLTAIC UTILITY DISCONNECT SWITCH. <br />NEW DEDICATED PV SYSTEM COMBINER PANEL. <br />= ROOF OBSTRUCTIONS <br />= FIRE PATHWAY <br />EXISTING EXISTING MAIN SERVICE PANEL TIED TO <br />EXTERIOR UTILITY METER. <br />10 NEW CANADIAN SOLAR CS3N-390MS [BLK] BLACK <br />MODULES WITH 10 NEW ENPHASE ENERGY <br />I7PLUS-72-2-US [240V] INVERTERS, MOUNTED ON <br />THE BACK OF EACH MODULES. <br />ROOF SECTIONS <br />SCALE: 1/16" = 1'-0" <br />1 SITE PLAN <br />A1.0 <br />C <br />M <br />1535 W POMONA ST <br />FRONT OF HOUSE <br />N <br />THE MAXIMUM GAP BETWEEN <br />MOUNTING POINT IS 72"ROOF #01 MODULE - 10 <br />SLOPE - 23° <br />AZIMUTH - 210° <br />MATERIAL - COMPOSITION SHINGLE <br />WOOD SIZE & SPACING - 2"X4" @ 24" O.C. <br />36 <br />" <br /> <br />P <br />A <br />T <br />H <br />W <br />A <br />Y <br />18" FIRE SETBACK <br />18" FIRE SETBACK <br />72" <br />ROOF #01 <br />S NEW SUB PANEL. <br />NOTE: CONTRACTOR IS RESPONSIBLE ON WATER <br />PROOFING AND TO FIELD VERIFY ALL ASSUMPTIONS <br />LISTED ON THE PLANS PRIOR TO INSTALLATIONS. <br />NOTE: THE DESIGN WIND PRESSURES FOR ROOF TOP <br />SOLAR PANELS LOCATED ON ENCLOSED OR <br />PARTIALLY ENCLOSED BUILDINGS OF ALL <br />HEIGHTS,WITH PANELS PARALLEL TO THE ROOF <br />SURFACE,WITH A TOLERANCE OF 2°AND WITH A <br />MAXIMUM HEIGHT ABOVE THE ROOF SURFACE,H2,NOT <br />EXCEEDING 10IN.A MINIMUM GAP OF <br />0.25IN.(6.4MM)SHALL BE PROVIDED BETWEEN ALL <br />PANELS,WITH THE SPACING OF GAPS BETWEEN <br />PANELS NOT EXCEEDING 6.7FT(2.04M).IN ADDITION,THE <br />ARRAY SHALL BE LOCATED AT LEAST 2*H2 FROM THE <br />ROOF EDGE,A GABLE RIDGE,OR A HIP RIDGE. <br />1 STORY HOUSE <br />ROOF MATERIAL - COMPOSITION SHINGLE <br />36 <br />" <br /> <br />P <br />A <br />T <br />H <br />W <br />A <br />Y <br /> <br />AC <br />This item has been digitally signed <br />and sealed on May 17, 2023 <br />1535 W Pomona St <br />06/26/23