My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1535 W Pomona St - Plan
PBA
>
Building
>
ProjectDox
>
P
>
Pomona St
>
1535 W Pomona St
>
1535 W Pomona St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 11:58:17 AM
Creation date
6/1/2025 11:58:10 AM
Metadata
Fields
Template:
Plan
Permit Number
20180112
101115585
Full Address
1535 W Pomona St
Document Relationships
101115585 - Permit
(Permit - Plan)
Path:
\Building\Permits\P\Pomona St\1535 W Pomona St
20180112 - Permit
(Permit - Plan)
Path:
\Building\Permits\P\Pomona St\1535 W Pomona St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
SHEET NAME <br />SHEET SIZE <br />SHEET NUMBER <br />ANSI B <br />11" X 17" <br />SIGNATURE WITH SEAL <br />PROJECT NAME & <br />ADDRESS <br />E1.0 <br />DATE: 2/17/2023 <br />1 <br />5 <br />3 <br />5 <br /> <br /> W <br /> <br />P <br />O <br />M <br />O <br />N <br />A <br /> <br />S <br />T <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br />, <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />FE <br />L <br />IP <br />E <br /> <br />E <br />L <br />IZ <br />A <br />L <br />DE <br /> R <br />ES <br />I <br />D <br />E <br />N <br />C <br />E <br />TROY STOKES <br />2491 ALLUVIAL AVE <br />#22 CLOVIS, CA 93611 <br />CONTRACTOR LIC#: #904259 <br />PHONE #: 559-797-2232 <br />GENERAL B,C10-ELECTRICAL <br />DESCRIPTION DATE REV <br />REVISIONS <br />INITIAL DESIGN 2/17/2023 00 <br />NOTES <br />NOTES <br />1. THIS SYSTEM SHALL COMPLY WITH ALL APPLICABLE CODES INCLUDING: THE 2022 CALIFORNIA BUILDING CODE, <br />CALIFORNIA FIRE CODE, CALIFORNIA ELECTRIC CODE, CALIFORNIA MECHANICAL CODE CALIFORNIA RESIDENTIAL <br />CODE, CALIFORNIA PLUMBING CODE, CALIFORNIA BUILDING STANDARDS CODE, CALIFORNIA HEALTH AND SAFETY <br />CODE, IEEE STANDARD 929, UL STANDARD 1741, 2022 RESIDENTIAL CODE, AND THE MANUFACTURERS' LISTINGS AND <br />INSTALLATION INSTRUCTIONS. <br />2. ALL WORK TO COMPLY WITH CEC ARTICLE 690 <br />3. UTILITY SHALL BE NOTIFIED BEFORE ACTIVATION OF PV <br />4. REMOVAL OF A UTILITY-INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT SYSTEM DISCONNECT THE <br />BUILDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE PV SOURCE AND/OR OUTPUT <br />CIRCUIT GROUNDED CONDUCTOR <br />5. ALL PV SYSTEM COMPONENTS SHALL BE LISTED BY A RECOGNIZED TESTING <br />6. WIRING MATERIALS SHALL COMPLY WITH MAXIMUM CONTINUOUS CURRENT OUTPUT AGENCY AT 25° C; WIRE SHALL <br />BE WET RATED AT 90°C <br />7. EXPOSED PHOTOVOLTAIC SYSTEM CONDUCTORS ON THE ROOF WILL BE USE-2 OR PV TYPE WIRE. <br />8. ALL EXTERIOR CONDUIT, FITTINGS, AND BOXES SHALL BE RAIN-TIGHT AND APPROVED FOR USE IN WET LOCATIONS <br />(NEC 314.15) <br />9. ALL METALLIC RACEWAYS AND EQUIPMENT SHALL BE BONDED AND ELECTRICALLY CONTINUOUS (NEC 250.90, 250.96) <br />10. FOR UNGROUNDED SYSTEMS, THE PHOTOVOLTAIC SOURCE AND OUTPUT CIRCUITS SHALL BE PROVIDED WITH A <br />GROUND-FAULT PROTECTION DEVICE OR SYSTEM THAT DETECTS A GROUND FAULT, INDICATES THAT FAULT HAS <br />OCCURED, AND AUTOMATICALLY DISCONNECTS ALL CONDUCTORS OR CAUSES THE INVERTER TO AUTOMATICALLY <br />CEASE SUPPLYING POWER TO OUTPUT CIRCUITS (CEC 690.35(C)) <br />11. ANY REQUIRED GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS, EXCEPT FOR SPLICES OR JOINTS AT <br />BUSBARS WITHIN LISTED EQUIPMENT (CEC 250.64C) <br />12. ALL PV MODULES AND ASSOCIATED EQUIPMENT SHALL BE PROTECTED FROM ANY PHYSICAL DAMAGE <br />13. ALL FIELD-INSTALLED JUNCTION, PULL, AND OUTLET BOXES LOCATED BEHIND MODULES SHALL BE ACCESSIBLE <br />DIRECTLY OR BY DISPLACEMENT OF A MODULE SECURED BY REMOVABLE FASTENERS <br />14. FOR GROUNDED SYSTEMS, THE INVERTER IS EQUIPPED WITH GROUND FAULT PROTECTION AND A GFI FUSE PORT <br />FOR GROUND FAULT INDICATION <br />15. WHEN BACKFED BREAKER IS THE METHOD OF UTILITY INTERCONNECTION, THE BREAKERS SHALL NOT READ "LINE <br />AND LOAD" <br />16. THE INSTALLED SOLAR SYSTEM HAS A DISTRIBUTED WEIGHT OF LESS THAN 4 PSF <br />17. THE CONCENTRATED LOAD FOR EACH VERTICAL SUPPORT IS LESS THAN 45 LBS <br />19. THE WORKING CLEARANCES AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL <br />18. AC DISCONNECT IS A "KNIFE BLADE" TYPE DISCONNECT AS THE NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED <br />IN ACCORDANCE WITH NEC 110.26 <br />20. THE PHOTOVOLTAIC INVERTER WILL BE LISTED AS UL 1741 <br />21. SMOKE ALARMS AND CARBON MONOXIDE ALARMS ARE REQUIRED TO BE RETROFITTED COMPLIANT ONTO THE <br />EXISTING DWELLING AS PER THE 2022 CRC. THESE SMOKE ALARMS ARE REQUIRED TO BE IN ALL BEDROOMS, <br />OUTSIDE EACH BEDROOM, AND AT LEAST ONE ON EACH FLOOR OF THE HOUSE. CARBON MONOXIDE ALARMS ARE <br />REQUIRED TO BE RETROFITTED OUTSIDE EACH BEDROOM AND AT LEAST ONE ON EACH FLOOR OF THE HOUSE. <br />THESE ALARMS MAY BE SOLELY BATTERY OPERATED IF THE PHOTOVOLTAIC PROJECT DOES NOT INVOLVE THE <br />REMOVAL OF INTERIOR WALL AND CEILING FINISHES INSIDE THE HOME; OTHERWISE, THE ALARMS MUST BE HARD <br />WIRED AND INTERCONNECTED. (CRC R314, R315) <br />22. SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED PER CRC SECTIONS R314 AND 315 TO BE VERIFIED AND <br />INSPECTED BY THE INSPECTOR IN THE FIELD. <br />23. WHEN APPLYING THE 120% RULE OF CEC 705.12(D)(2), THE SOLAR BREAKER TO BE POSITIONED AT THE OPPOSITE <br />END OF THE BUS FROM THE MAIN BREAKER PER 705.12(D)(7) <br />24. PLUMBING AND MECHANICAL VENTS THROUGH THE ROOF SHALL NOT BE COVERED BY SOLAR MODULES - NO <br />BUILDING, PLUMBING, OR MECHANICAL VENTS TO BE COVERED OR OBSTRUCTED <br />25. EXISTING UFER. IF THERE IS NO UFER,INSTALL (2) NEW 5/8"X8' GROUND ROD 6' APART.WATER BOND <5' FROM BLDG <br />ENTRANCE. #4 AWG GEC TO BOND GROUND ROD AND WATER PIPE. SPLICES SHALL BE IRREVERSIBLE CRIMPED <br />26. PLAQUES SHALL BE METAL OR PLASTIC, WITH ENGRAVED OR MACHINE PRINTED LETTERS, OR ELECTRO-PHOTO <br />PLATING, IN A CONTRASTING COLOR TO THE PLAQUE-PLACARD IS TWO COLOR/RED FACE-WHITE CORE ENGRAVED <br />PLASTIC. PLAQUE SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS.PLAQUE AT MSP <br />This item has been digitally signed <br />and sealed on May 17, 2023 <br />1535 W Pomona St <br />06/26/23
The URL can be used to link to this page
Your browser does not support the video tag.