Laserfiche WebLink
~5 <br />9 <br />. <br />1 <br />2 <br />' <br /> <br />~149.58' <br />~5 <br />9 <br />. <br />1 <br />2 <br />' <br />~149.58' <br />ACD <br />JB <br />CB <br />MS <br />P <br />UM <br />36 <br />' <br />- <br />5 <br />" <br />38'-5" <br />5' <br />- <br />5 <br />" <br />53'-1" <br />ACDCB <br />MS <br />P <br />UM <br />SITE PLAN WITH ROOF PLAN <br />REV <br />SHEET NAME <br />SHEET NUMBER <br />DATE DESCRIPTION <br />VERSION <br />PV-1 <br />PROJECT NAME <br />UR04/27/2023 INITIAL RELEASE <br />HE <br />R <br />A <br />S <br />, <br /> <br />M <br />O <br />U <br />R <br />E <br />E <br />N <br />14 <br />3 <br />0 <br /> <br />N <br /> <br />B <br />A <br />K <br />E <br />R <br /> <br />S <br />T <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br /> <br />U <br />S <br />A <br />AP <br />N <br /># <br /> <br />4 <br />0 <br />5 <br />2 <br />5 <br />1 <br />1 <br />3 <br />UT <br />I <br />L <br />I <br />T <br />Y <br />: <br /> <br />S <br />C <br />E <br />AH <br />J <br />: <br /> <br />C <br />I <br />T <br />Y <br /> <br />O <br />F <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />SHEET SIZE <br />ANSI B <br />11" X 17" <br />ENERGY RENOVATION CENTER <br />11731 Sterling Avenue, Unit G <br /> Riverside, CA 92503 <br />LIC:- 1009326 <br />PH:- 8886040226 <br />pm@energyrenovationcenter.com <br />SITE PLAN WITH <br />ROOF PLAN <br />1 SCALE: 1/16" = 1'-0" <br />NOTE: <br />A. ALL ELECTRICAL EQUIPMENT, INVERTERS, <br />DISCONNECTS, MAIN SERVICE PANELS, ETC. SHALL <br />NOT BE INSTALLED WITHIN 3’ OF THE GAS METERS’ <br />SUPPLY OR DEMAND PIPING. <br /> ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE <br />THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS <br />OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN <br />LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD <br />OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS. <br />LEGEND <br />UTILITY METER <br />AC DISCONNECT <br />JUNCTION BOX <br />UM <br />ACD <br />JB <br />MSP MAIN SERVICE PANEL <br />GATE <br />FENCE <br />CONDUIT <br />VENT, ATTIC FAN <br />(ROOFOBSTRUCTION) <br />ENPHASE IQ COMBINER 3CB <br />NOTE: * 3/4" OR GREATER IMC, RMC, FMC, LFMC, PVC, <br />HDPE, NUCC, RTRC, LFNC, FMT, ENT OR EMT <br />CONDUIT RUN EXPOSED CONDUIT RUN SHALL BE <br />MIN. 7/8" ABOVE ROOF. * ROMEX RUN INSIDE ATTIC <br />ROOF DESCRIPTION <br />ROOF TYPE ASPHALT SHINGLE <br />ROOF <br />ROOF <br />ARRAY <br />ROOF <br />TILT AZIMUTH PV AREA <br />(SQ.FT.) <br />NO. OF <br />MODULE <br />#1 18° 270° 270.38 14 <br />68.50" <br />40 <br />. <br />6 <br />0 <br />" <br />PHOTOVOLTAIC MODULES <br />HANWHA Q.CELLS Q.PEAK DUO <br />BLK-G6+/AC (340W) <br />ENLARGED VIEW <br />(E) 200A MAIN SERVICE PANEL <br />WITH (E) 200A MAIN BREAKER <br />(E) UTILITY METER <br />(N) 30A NON FUSED AC DISCONNECT <br />(N) ENPHASE IQ COMBINER BOX 3 <br />(N) 3/4" OR GREATER EMT CONDUIT <br />RUN (7/8 INCHES ABOVE ROOF) <br />EXISTING <br />DRIVEWAY <br />PROPERTY LINE <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br />PROPERTY LINE <br />ROOF ACCESS POINT <br />(E) FENCE <br />(E) GATE <br />(E) STRUCTURE <br />(E) TREE (TYP.) <br />(N) JUNCTION BOX <br />SEE IN ENLARGE VIEW <br />TW <br />O <br />- <br /> <br />S <br />T <br />O <br />R <br />Y <br />HO <br />U <br />S <br />E <br />N <br />B <br />A <br />K <br />E <br />R <br /> <br />S <br />T <br />ROOF #1 <br />(14) HANWHA Q.CELLS Q.PEAK DUO BLK-G6+/AC (340W) MODULES <br />INTEGRATED WITH ENPHASE ENERGY IQ7PLUS-72-ACM-US OR <br />IQ7PLUS-72-E-ACM-US MICRO-INVERTERS <br />27 Apr 2023 <br />EXP : 30 Sep 2023 <br />STRUCTURAL ONLY <br />1430 N Baker St <br />06/12/23