My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1605 E 4th St - Plan
PBA
>
Building
>
ProjectDox
>
F
>
Fourth St
>
1605 E Fourth St
>
1605 E 4th St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 11:59:37 AM
Creation date
6/1/2025 11:59:30 AM
Metadata
Fields
Template:
Plan
Permit Number
20178713
101113848
Full Address
1605 E Fourth St
Document Relationships
101113848 - Permit
(Permit - Plan)
Path:
\Building\Permits\F\Fourth St\1605 E Fourth St
20178713 - Permit
(Permit - Plan)
Path:
\Building\Permits\F\Fourth St\1605 E Fourth St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
COVER PAGE <br />(2 <br />1 <br />. <br />1 <br />2 <br />0 <br />K <br />W <br /> <br />D <br />C <br />) <br />REV <br />SHEET NAME <br />SHEET NUMBER <br />DATE DESCRIPTION <br />REVISIONS <br />PROJECT NAME & ADDRESS <br />HI <br />N <br />E <br />R <br /> <br />P <br />A <br />R <br />T <br />N <br />E <br />R <br />S <br />16 <br />0 <br />5 <br /> <br />E <br /> <br />4 <br />T <br />H <br /> <br />S <br />T <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />A11/10/2022 FOR REVIEW <br />SIGNATURE & SEAL <br />CONTRACTOR SIGNATURE <br />SOLAR SYMPHONY <br />1255 STONE DR. <br />SAN MARCOS, CA 92078 <br />PHONE #: (760) 300-4141 <br />EMAIL: ops@solarsymphony.com <br />CSLB LICENSE: 988146 <br />CLASS: C-46 <br />B11/18/2022 MODULE LAYOUT <br />C04/19/2023 REVISION <br />D09/26/2023 REVISION <br />CO <br />N <br />S <br />T <br />R <br />U <br />C <br />T <br />I <br />O <br />N <br /> <br />T <br />Y <br />P <br />E <br />: <br /> <br />I <br />I <br />I <br />- <br />B <br />OC <br />C <br />U <br />P <br />A <br />N <br />C <br />Y <br />: <br /> <br />G <br />R <br />O <br />U <br />P <br /> <br />B <br /> <br />- <br /> <br />B <br />U <br />S <br />I <br />N <br />E <br />S <br />S <br />PROJECT DESCRIPTION: <br />THIS ROOF-MOUNTED SOLAR PHOTOVOLTAIC (PV) -23.520KW(DC STC) SYSTEM IS TO BE INSTALLED AT THE HINER PARTNERS LOCATED IN SANTA ANA, CA <br />92701. THE ENERGY PRODUCED BY THE PV SYSTEM SHALL BE INTERCONNECTED WITH THE UTILITY GRID THROUGH EXISTING ON-SITE ELECTRICAL <br />EQUIPMENT VIA BACKFEED BREAKER IN THE EXISTING DISTRIBUTION PANEL LOCATED TO THE BUILDING. <br />VICINITY MAP 2 <br />PROJECT LOCATION <br />AERIAL MAP 1 <br />GENERAL NOTES: <br />1. ALL ELECTRICAL MATERIALS SHALL BE NEW AND LISTED BY RECOGNIZED ELECTRICAL <br />TESTING LABORATORY. <br />2. OUTDOOR EQUIPMENT SHALL BE AT LEAST NEMA 3R RATED. <br />3. ALL METALLIC EQUIPMENT SHALL BE GROUNDED. <br />4. ALL SPECIFIC WIRING IS BASED ON THE USE OF COPPER/ALUMINUM. <br />5. CONTRACTOR SHALL OBTAIN ELECTRICAL PERMITS PRIOR TO INSTALLATION AND SHALL <br />COORDINATE ALL INSPECTIONS, TESTING COMMISSIONING AND ACCEPTANCE WITH THE <br />CLIENT, UTILITY CO. AND CITY INSPECTORS AS NEEDED. <br />6. DRAWINGS ARE DIAGRAMMATIC ONLY, ROUTING OF RACEWAYS SHALL BE OPTION OF THE <br />CONTRACTOR UNLESS OTHERWISE NOTED AND SHALL BE COORDINATED WITH OTHER <br />TRADES. <br />7. IF THE DISTANCES FOR CABLE RUNS ARE DIFFERENT THAN SHOWN, THE CONTRACTOR <br />SHALL NOTIFY THE ELECTRICAL CONTRACTOR TO VALIDATE THE WIRE SIZE. FINAL <br />DRAWINGS WILL BE RED-LINED AND UPDATED AS APPROPRIATE. <br />8. WHENEVER A DISCREPANCY IN QUALITY OF EQUIPMENT ARISES ON THE DRAWING OR <br />SPECIFICATIONS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND <br />INSTALLING ALL MATERIAL AND SERVICES REQUIRED BY THE STRICTEST CONDITIONS <br />NOTED ON THE DRAWINGS OR IN THE SPECIFICATIONS. <br />9. ALL BROCHURES, OPERATION MANUALS, CATALOGS, SHOP DRAWINGS, ETC. SHALL BE <br />HANDED OVER TO OWNER'S REPRESENTATIVE AT THE COMPLETION OF WORK. <br />10. IF THE ROOF MATERIAL OR ROOF STRUCTURE NOT ADEQUATE FOR PV INSTALLATION, CALL <br />ENGINEER PRIOR TO INSTALL. THE CONTRACTOR IS RESPONSIBLE TO VERIFY THAT THE <br />ROOF IS CAPABLE OF WITHSTANDING THE EXTRA WEIGHT. <br />11.CUSTOM MADE EQUIPMENT SHALL HAVE COMPLETE TEST DATA SUBMITTED BY THE <br />MANUFACTURER ATTESTING TO ITS SAFETY. <br />PHOTOVOLTAIC NOTES: <br />1. ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED, LISTED AND IDENTIFIED UL 1703. <br />2. SOLAR SYSTEM SHALL NOT COVER ANY PLUMBING OR MECHANICAL VENTS <br />3. MODULES AND SUPPORT STRUCTURES SHALL BE GROUNDED. <br />4. REMOVAL OF AN INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE BONDING CONNECTION <br />BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE PHOTOVOLTAIC SOURCE AND/OR OUTPUT CIRCUIT GROUNDED <br />CONDUCTORS. <br />5. SOLAR INVERTER MUST HAVE A MANUFACTURE INSTALLED DISCONNECTING MEANS THAT PREVENTS PARALLEL FEEDING <br />UTILITY LINES DURING POWER OUTAGE. <br />6. ALL PV MODULES AND ASSOCIATED EQUIPMENT AND WIRING SHALL BE PROTECTED FROM ANY PHYSICAL DAMAGE. <br />7. LIVE PARTS OF PV SOURCE CIRCUITS AND PV OUTPUT CIRCUITS OVER 150V TO GROUND SHALL NOT BE ACCESSIBLE TO OTHER <br />THAN QUALIFIED PERSONS WHILE ENERGIZED. <br />8. INVERTER IS EQUIPED W/ INTEGRATED GFDI, THUS PROVIDING GROUND FAULT PROTECTION. <br />9. ALL CONDUCTORS SHALL BE COPPER AND 90 DEG RATED. <br />10. ALL ELECTRICAL EQUIPMENT SHALL BE LISTED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY OR APPROVED BY THE <br />DEPARTMENT. <br />11. THE OUTPUT OF A UTILITY INTERACTIVE-INVERTER SHALL BE PERMITTED TO BE CONNECTED TO THE SUPPLY SIDE OF THE <br />SERVICE DISCONNECTING MEANS AS PER 230.82(6). <br />12. A SINGLE CONDUCTOR SHALL BE PERMITTED TO BE USED TO PERFORM THE MULTIPLE FUNCTIONS OF DC GROUNDING, AC <br />GROUNDING AND BONDING BETWEEN AC AND DC SYSTEMS AS PER NEC 690.47(C) AND SIZED AS PER SEC 250.166. <br />13. EQUIPMENT GROUND CONDUCTOR REQUIRED IN RACEWAYS SIZED PER CEC 250-166. <br />14. PER ART 250.92. NON-CURRENT CARRYING METAL PARTS OF EQUIPMENT SHALL BE EFFECTIVELY BONDED TOGETHER. BOND <br />BOTH ENDS OF RACEWAYS. <br />17.110.2 APPROVAL:ALL ELECTRICAL EQUIPMENT SHALL BE LABELED,LISTED OR CERTIFIED BY A NATIONAL RECOGNIZED <br />TESTEING LABORATORY ACCREDITED BY THE UNITED STATES OCCUPATIONAL SAFETY HEALTH ADMINISTRATION. <br />SHEET INDEX <br />S.NO SHEET NAME <br />PV-1 COVER PAGE <br />PV-2 SITE PLAN <br />PV-3 ROOF PV LAYOUT <br />PV-4 STRING LAYOUT <br />PV-5 ATTACHMENT DETAIL <br />PV-6 ELECTRICAL LINE DIAGRAM <br />PV-7 ELECTRICAL CALCULATION <br />PV-8 SAFETY PLACARDS <br />PV-9 MODULE & INVERTER DATA SHEET <br />PV-10 RACKING & ATTACHMENT DATA SHEET <br />PV-11 COVER SHEET <br />PV-12 KEY PLAN <br />PV-13 ARRAY LAYOUTS <br />PV-14 RM5 DETAILS <br />PV-15 RM5 DETAILS <br />ELECTRICAL INFORMATION: <br />(E) DISTRIBUTION PANEL BUS SIZE: 400A <br />MAX AC VOLTAGE: 120/208V; 3P, 4WIRE <br />(N) 1 - SOLAREDGE SE17.3KUS INVERTER <br />(N) 1 - AC DISCONNECT : 100A, NEMA 3R (UNFUSED) <br />(N) JUNCTION BOX, 1000V <br />OWNER INFORMATION: <br />HINER PARTNERS <br />(23.520KW DC) <br />1605 E 4TH ST <br />SANTA ANA, CA 92701, USA <br />GOVERNING CODES:- <br />· 2022 CA BUILDING CODE <br />· 2022 CA RESIDENTIAL CODE <br />· 2022 CA MECHANICAL CODE <br />· 2022 CA ELECTRICAL CODE <br />· 2022 CA GREEN CODE <br />· 2022 CA PLUMBING CODE <br />· 2022 CA ENERGY CODE <br />· 2022 CA FIRE CODE <br />ALL OTHER ORDINANCE ADOPTED BY THE LOCAL <br />GOVERNING AGENCIES <br />PHOTOVOLTAIC SYSTEM SUMMARY:- <br />SYSTEM SIZE: DC STC: 21.120 KW <br />SYSTEM SIZE: AC CEC / PTC: 19.460 KW <br />SOLAR MODULES: (44) HANWHA Q CELLS 480WATT <br />MODEL #: (Q.PEAK DUO XL-G10.3/BFG) <br />INVERTER: SOLAREDGE <br />MODEL #: (1) SE17.3KUS <br />OPTIMIZER: (1) SOLAREDGE <br />MODEL #: (22) P1101 <br />MOUNTING SYSTEM: UNIRAC BALLESTED RM5 <br />INVERTER AC OUTPUT: 1*17300 W = 17.30 KW <br />PROJECT INFORMATION: <br />· APN: N/A <br />· AHJ: SANTA ANA CITY <br />· PANEL UPGRADE: NO <br />· FIRE RATING: CLASS 'A' TYPE 1 <br />· NO. OF FLOORS: 1 <br /> TYPE: III-B <br /> OCCUPANCY: B - BUSINESS <br />0-Title <br />Bldg# 101113848 <br />Elec# 20178713 <br />Issued 11/13/23 <br />APPROVALS: <br />PLNG - HJacinto <br />BLDG - JLo <br />ELEC - MSmith <br />1605 E 4th St - 101113848 and <br />20178713 <br />11/15/2023
The URL can be used to link to this page
Your browser does not support the video tag.