Laserfiche WebLink
PROJECT TITLE:Hiner Partners <br />PROJECT ID:QR-20230908-45506 <br />Name:Solar Symphony Construction, Inc.Designed By: SK <br />Address:1605 E 4th St Product: RM5 <br />City, State:Santa Ana, CA 92701, USA 480 Watt Panels <br />Module:Hanwha/Q-Cells Q.Peak Duo XL-G10.2-1349 Sq Ft. <br />480 Watts 21.1 kWs <br />Elevation 139 ft <br />Numerical coefficient - Imperial Units 0.00255 ← Sec on 26.10.1 (ASCE 7-16) <br />Median Roof Height, h 22 ft <br />Exposure B ← Sec on 26.7 (ASCE 7-16) <br />Risk Category II ← Table 1.5-1 (ASCE 7-16) <br />Basic Wind Speed, V 95 mph <br />Velocity Pressure Exposure Coefficient, Kz 0.70 ← Table 26.10.1 (ASCE 7-16) <br />Topographic Factor (assuming level ground), Kzt 1.00 ← Sec on 26.8 (ASCE 7-16) <br />Directionality factor, Kd 0.85 ← Table 26.6-1 (ASCE 7-16) <br />Velocity Pressure at Height qh = 0.00255KzKztKdV2 13.7 psf ← Equa on 26.10.1 (ASCE 7-16) <br />Design Life Factor, Kdl 1.00 ← Equa on C26.5-4 (ASCE 7-16) <br />Design Life Velocity Pressure qh x Kdl <br />2 13.7 psf <br />Design pressure p = qhGCp <br />WIND DESIGN <br />9-9-23 2:47 PM <br />WIND DESIGN <br />VERSION:INT 10.20.22 <br />PROJECT REPORT <br />6 <br />1605 E 4th St - 101113848 and <br />20178713 <br />11/15/2023