Laserfiche WebLink
4'-11" <br />44'-0"7'-4" <br />4' <br />- <br />9 <br />" <br />54 <br />' <br />- <br />7 <br />" <br />64 <br />' <br />- <br />7 <br />" <br />MD <br />P <br />UM <br />JB <br />INV ACD <br />(2 <br />1 <br />. <br />1 <br />2 <br />0 <br />K <br />W <br /> <br />D <br />C <br />) <br />REV <br />SHEET NAME <br />SHEET NUMBER <br />DATEDESCRIPTION <br />REVISIONS <br />PROJECT NAME & ADDRESS <br />HI <br />N <br />E <br />R <br /> <br />P <br />A <br />R <br />T <br />N <br />E <br />R <br />S <br />16 <br />0 <br />5 <br /> <br />E <br /> <br />4 <br />T <br />H <br /> <br />S <br />T <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />A11/10/2022FOR REVIEW <br />SIGNATURE & SEAL <br />CONTRACTOR SIGNATURE <br />SOLAR SYMPHONY <br />1255 STONE DR. <br />SAN MARCOS, CA 92078 <br />PHONE #: (760) 300-4141 <br />EMAIL: ops@solarsymphony.com <br />CSLB LICENSE: 988146 <br />CLASS: C-46 <br />B11/18/2022MODULE LAYOUT <br />C04/19/2023REVISION <br />D09/26/2023REVISION <br />CO <br />N <br />S <br />T <br />R <br />U <br />C <br />T <br />I <br />O <br />N <br /> <br />T <br />Y <br />P <br />E <br />: <br /> <br />I <br />I <br />I <br />- <br />B <br />OC <br />C <br />U <br />P <br />A <br />N <br />C <br />Y <br />: <br /> <br />G <br />R <br />O <br />U <br />P <br /> <br />B <br /> <br />- <br /> <br />B <br />U <br />S <br />I <br />N <br />E <br />S <br />S <br />PV LAYOUT <br />ROOF <br />MODULE TYPE, DIMENSIONS & WEIGHT <br />NUMBER OF MODULES = 44 MODULES <br />MODULE TYPE = Q.PEAK DUO XL-G10.3/BFG 480 <br />WEIGHT = 64.2 LBS / 29.1 KG. <br />MODULE DIMENSIONS = 87.2"X 41.1" = 24.89 SF <br />ROOF DESCRIPTION <br />ROOF TYPE ROLLED ASPHALT <br />ROOF # OF <br />MODULES <br /> MODULE <br />TILT AZIMUTH RAFTER <br />SIZE <br />RAFTER <br />SPACING <br />#1 44 5°180°2"x4"24" O.C. <br />ARRAY AREA & ROOF AREA CALC'S <br />ROOF # OF <br />MODULES <br />ARRAY <br />AREA <br />(Sq. Ft.) <br />ROOF <br />AREA <br />(Sq. Ft.) <br />ROOF AREA <br />COVERED BY <br />ARRAY (%) <br />#1 44 1095.16 6691.83 16 <br />LEGEND <br />CP <br />INV - INVERTER <br />- AC COMBINER PANEL <br />- VENT (ROOF OBSTRUCTION) <br />- CONDUIT <br />ACD - AC DISCONNECT <br />- UTILITY METERUM <br />MDP - DISTRIBUTION PANEL <br />87 <br />. <br />2 <br />" <br />41.1" <br />HANWHA Q CELL Q.PEAK DUO <br />XL-G10.3/BFG 480W MODULES <br />1.38" <br />1 PV ROOF LAYOUT <br />SCALE: 3/32" = 1'-0"PV-3 <br />- PV MODULE <br />CONDUIT RUN (ON ROOF) <br />TO INVERTER <br />ROOF ACCESS POINT <br />ROOF #1 <br />(44) HANWHA Q CELLS <br />Q.PEAK DUO XL-G10.3/BFG MODULES <br />UNIRAC BALLESTED RM5 <br />(N) JUNCTION BOX <br />INSIDE BUILDING <br />(E) FRONT OF BUILDING <br />(E) BACK OF BUILDING <br />E 4TH ST <br />(E) UTILITY METER <br />(E) DISTRIBUTION PANEL, 400A <br />(N) AC DISCONNECT, 100A <br />(N) SOLAREDGE SE17.3KUS INVERTER <br />INSIDE BUILDING <br />EA <br />S <br />T <br />S <br />I <br />D <br />E <br /> <br />A <br />V <br />E <br />48" FIRE SETBACK <br />48 <br />" <br /> <br />F <br />I <br />R <br />E <br /> <br />S <br />E <br />T <br />B <br />A <br />C <br />K <br />48 <br />" <br /> <br />F <br />I <br />R <br />E <br /> <br />S <br />E <br />T <br />B <br />A <br />C <br />K <br />48" FIRE SETBACK <br />48" FIRE SETBACK <br />HATCH #1 <br />PV-1.0 <br />1605 E 4th St - 101113848 and <br />20178713 <br />11/15/2023