Laserfiche WebLink
SINGLE LINE <br />DIAGRAM <br />4SHEET: <br />REVISIONS: <br />DRAWN BY: <br />DATE: <br />PHOTOVOLTAIC <br />SYSTEM SIZE: <br />STANDARD ECO LLC <br />2125 S 48TH ST <br />TEMPE, AZ 85282 <br />CA License #:1074053 <br />26.40 kW AC <br />26.40 kW DC <br />SINGLE PHASE 120V/240V <br />CHINESE ISLAMIC CENTER <br />1610 E 1ST STREET, SANTA ANA, CA <br />92701 <br />08/29/2023 <br />ASD - JG <br />ASD - JG 10/08/2023 <br />ASD - JG 02/01/2024 <br />ASD - JG 02/16/2024 <br />ASD - JG 03/05/2024 <br />ASD - JG 04/04/2024 <br />#6 AWG CU BARE GROUNDING <br />ELECTRODE CONDUCTOR (GEC). TO RUN <br />INDEPENDENTLY OF OTHER <br />CONDUCTORS AND TIE DIRECTLY INTO <br />AC GROUNDING ELECTRODE <br />GROUNDING WILL <br />ORIGINATE FROM THE <br />NEUTRAL TO GROUND WITH <br />AN EQUIPMENT BOND. <br />SERIES A - (12x) MODULES <br />APTOS - DNA-120-BF10-440W <br />(6x)APSYSTEMS - DS3 [240V] <br />ARRAY JUNCTION BOX <br />(AS NECESSARY) <br />PRE-FAB AC INTERCONNECT CABLE <br />WITH FACTORY INSTALLED <br />INTERCONNECT CONNECTORS <br />& #6 AWG BARE CU GROUND <br />(N) 150A COMBINER <br />PANEL <br />3/4" EMT <br />(2x) #10 AWG <br />& (1x) #6 AWG GROUND <br />(THWN-2 CU WIRE) <br />(PER STRING) <br />1-1/2" PVC <br />APPROX 45' CONDUIT <br />BURIED PER NEC TABLE 300.5 <br />(3x) #2/0 AWG <br />& (1x) #6 AWG GROUND <br />(THWN-2 CU WIRE) <br />(N) WIRE TAPS W/ NO <br />PIERCING MULTI-TAP <br />CONNECTORS <br />M <br />GROUNDING ELECTRODE <br />(SEE ELECTRICAL NOTES) <br />(E) 600A MAIN SERVICE <br />PANEL WITH (E) 600A <br />MAIN BREAKER <br />(E) SCE BI-DIRECTIONAL <br />SINGLE PHASE UTILITY <br />METER SOCKET <br />SERIES B - (12x) MODULES <br />APTOS - DNA-120-BF10-440W <br />(6x)APSYSTEMS - DS3 [240V] <br />(N) 30ASERIES C - (12x) MODULES <br />APTOS - DNA-120-BF10-440W <br />(6x)APSYSTEMS - DS3 [240V] <br />SERIES D - (12x) MODULES <br />APTOS - DNA-120-BF10-440W <br />(6x)APSYSTEMS - DS3 [240V] <br />(E) LOADS <br />(N) 30A <br />(N) 30A <br />(N) 30A <br />FEED FROM UTILITY GRID <br />120/240V, 1Ø, 3W <br />1-1/2" EMT <br />(3x) #2/0 AWG <br />(THWN-2 CU WIRE) <br />SERIES E - (12x) MODULES <br />APTOS - DNA-120-BF10-440W <br />(6x)APSYSTEMS - DS3 [240V] <br />(N) 30A <br />GEC TO BE BONDED TO STEEL CARPORT <br />STRUCTURE TO ACT AS GROUNDING <br />ELECTRODE <br />#6 AWG CU BARE GROUNDING <br />ELECTRODE CONDUCTOR (GEC). TO RUN <br />INDEPENDENTLY OF OTHER <br />CONDUCTORS AND TIE DIRECTLY INTO <br />AC GROUNDING ELECTRODE <br />MAX BACKFED CURRENT FOR OCPD: <br /> 3.7A(30) x 1.25 = 138.75A TOTAL <br />MAX AVAILABLE BACKFEED FOR SES BUS SIZE: <br />600A BUS x 1.2 = 720A - 600A BREAKER = <br />120A BACKFEED AVAILABLE <br />1.WHERE TWO SOURCES, ONE UTILITY AND THE OTHER AN INVERTER, ARE LOCATED AT OPPOSITE ENDS OF A BUSBAR THAT CONTAINS LOADS, THE SUM OF 125% OF THE INVERTER(S) OUTPUT CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTETICING THE BUSBAR SHALL NOT EXCEED 120% THE AMPACITY OF THE BUSBAR.2.IDENTIFICATION AND GROUPING OF PHOTOVOLTAIC DC CIRCUITS SHALL COMPLY WITH NEC 690.4(B) AND SHALL BE SEPARATED FROM OTHER NON PV SYSTEM CONDUCTORS.3.EXPOSED NON-CURRENT CARRYING METAL PARTS OF PHOTOVOLTAIC RACKING, EQUIPMENT, AND CONDUCTOR ENCLOSURES SHALL BE GROUNDED IN ACCORDANCE TO NEC 690.47 (C)(3), 250.64(C), 250.66, & 250.134 OR 250.136(A) AND SIZED PER 250.166 REGARDLESS OF VOLTAGE. 4.ALL CONDUIT ON ROOF NEEDS TO BE PLACED MINIMUM OF 7/8" ABOVE THE ROOF'S SURFACE.5.EACH MODULE (AND MICRO-INVERTER, IF APPLICABLE) SHALL BE GROUNDED PER THE MANUFACTURER'S INSTRUCTIONS USING THE BONDING MIDCLAMP / COMPONENTS, AND AT EACH ROW UTILIZING AMPHENOL HELIO LUGS (UL 2703). SPEC SHEETS CAN BE PROVIDED UPON REQUEST. <br />6.ELECTRICAL EQUIPMENT INSTALLED SHALL BE LISTED, LABELED, OR CERTIFIED FOR ITS USE BY A NATIONALLY <br />RECOGNIZED TESTING LABORATORY (NRTL). <br />7.ALL TERMINATIONS OF EQUIPMENT TO BE A MINIMUM 90 DEGREE CELCIUS PER CEC 110.14(C) & TABLE 310.15 (B)(16) 90 <br />DEGREE COLUMN COPPER. <br />8.FOR SERVICE UPGRADES, IF THE EXISTING GROUNDING ELECTRODE SYSTEM CAN NOT BE VERIFIED, OR IS ONLY METALLIC <br />WATER PIPING, OR IT HAS A RESISTANCE GREATER THAN 25 OHMS, IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A <br />SUPPLEMENTAL GROUNDING ELECTRODE AT LEAST 6' FROM THE EXISTING GROUNDING ELECTRODE. <br />9.ALL BREAKERS AND SERVICE EQUIPMENT ARE RATED AT 22kAIC OR HIGHER <br />10.GROUND BUSHINGS TO BE USED ON ALL METALLIC RACEWAYS. <br />11.. BATTERY LISTED AND LABELED FOR RESIDENTIAL USE IN ACCORDANCE WITH UL9540 PER SECTION R327 OF 2019 CRC. <br />BATTERY IS UL1973 CERTIFIED AND INVERTER IS UL1741 CERTIFIED <br />12. ALL ELECTRICAL SHOWN IN PLAN IS FOR A FIELD REVIEW PLAN REVIEW <br />13.INVERTERS ARE UL1741 COMPLIANT <br />ELECTRICAL NOTES <br />1.WHERE TWO SOURCES, ONE UTILITY AND THE OTHER AN INVERTER, ARE LOCATED AT OPPOSITE ENDS <br />OF A BUSBAR THAT CONTAINS LOADS, THE SUM OF 125% OF THE INVERTER(S) OUTPUT CIRCUIT <br />CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTETICING THE BUSBAR SHALL NOT <br />EXCEED 120% THE AMPACITY OF THE BUSBAR. <br />2.IDENTIFICATION AND GROUPING OF PHOTOVOLTAIC DC CIRCUITS SHALL COMPLY WITH NEC 690.4(B) <br />AND SHALL BE SEPARATED FROM OTHER NON PV SYSTEM CONDUCTORS. <br />3.EXPOSED NON-CURRENT CARRYING METAL PARTS OF PHOTOVOLTAIC RACKING, EQUIPMENT, AND <br />CONDUCTOR ENCLOSURES SHALL BE GROUNDED IN ACCORDANCE TO NEC 690.47 (C)(3), 250.64(C), 250.66, <br />& 250.134 OR 250.136(A) AND SIZED PER 250.166 REGARDLESS OF VOLTAGE. <br />4.ALL CONDUIT ON ROOF NEEDS TO BE PLACED MINIMUM OF 7/8" ABOVE THE ROOF'S SURFACE. <br />5.EACH MODULE (AND MICRO-INVERTER, IF APPLICABLE) SHALL BE GROUNDED PER THE <br />MANUFACTURER'S INSTRUCTIONS USING THE BONDING MIDCLAMP / COMPONENTS, AND AT EACH ROW <br />UTILIZING AMPHENOL HELIO LUGS (UL 2703). SPEC SHEETS CAN BE PROVIDED UPON REQUEST. <br />14. MICROINVERTERS CIRCUITS OPERATE AT LESS THAN 80VDC THUS ARE EXEMPT FROM CEC 690.11 <br />15. ANY CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER CEC300.6 C1, 310.10D <br />16.GROUND MOUNTED SYSTEM WIRING OVER 150V SHALL NOT BE ACCESSIBLE, EXCEP TO QUALIFIED <br />PERSONNEL. PROTECTIVE FENCING, SCREENING OR RACEWAYS WILL BE PROVIDED FOR AL WIRING OVER 150V PER CEC <br />690.7D <br />17. ALL PHOTOVOLTAIC OUTPUT CIRCUITS OPERATING ABOVE 30V SHALL BE ISNTALLED IN READILY <br />ACCESSIBLE LOCATIONS AND IN ELECTRICAL RACEWAYS PER CEC 690.31 A. CONNECTORS SHALL BE OIF THE LATCHING <br />OR LOCKING TYPE AND SHALL REQUIRE A TOOL FOR OPENING PER CEC 690.31 <br />(N) 200A UTILITY AC VISIBLE LOCKABLE <br />LABELED DISCONNECT SWITCH <br />EATON CUTLER HAMMER <br />DG224URK 600V <br />- FUSED - <br />(2x) 150A FUSES <br /> SERVICE ENTRANCE RATED <br />(OR EQUIVALENT) <br />150A <br />1610 E First St - 101118465 & <br />20182250 <br />5/7/2024