Laserfiche WebLink
REV: B <br />AHJ: CA-CITY OF SANTA ANA <br />33.766955, -117.844651 <br />APN: 396-05-604 <br />NAME: ALAN VAN HO <br />DRAFTED BY: ARUNDEEPAN R <br />ADDRESS: 1613 E BUFFALO AVE, <br />SANTA ANA, CA 92705 <br />UTILITY: SCE-SOUTHERN <br />CALIFORNIA EDISON <br />SCALE: AS NOTED <br />PRN NUMBER: SMT-76199 <br />PAPER SIZE: 17"X11"SHEET: E-03DATE: 04/29/2023 <br />DRAWING INFORMATION <br />CUSTOMER INFORMATION CONTRACTOR INFORMATION <br />QC'ED BY: SURYA PRAKASH P <br />SOLARMAX RENEWABLE ENERGY <br />PROVIDER INC. <br />3080 12TH ST, RIVERSIDE, CA 92507 <br />TEL: (951) 300-0788 <br />LICENSE NUMBER& <br />CLASS:972048/C-46 <br /> David Bingwen Hsu <br /> David Bingwen Hsu, Lic. Holder <br />ELECTRICAL NOTES <br />ELECTRICAL CALCULATIONS <br />DC SYSTEM SIZE- 8505W, AC SYSTEM SIZE - 6090W, CEC AC RATING - 7665W <br />ENPHASE IQ8PLUS-72-2-US <br />(240V)(SI-1) <br />MICRO INVERTER SPECIFICATIONS <br />MODEL <br />POWER RATING 290W <br />MAX OUTPUT CURRENT 1.21A <br />CEC WEIGHTED EFFICIENCY 97% <br />MAX NO OF MICRO INVERTERS/BRANCH 13 <br />MAX DC VOLTAGE 60V <br />10.83 AMAX POWER CURRENT:Imp <br />11.17 ASHORT CIRCUIT CURRENT:Isc <br />37.39 VMAX POWER VOLTAGE:Vmp <br />45.34 VOPEN CIRCUIT VOLTAGE:Voc <br />405 WMODULE POWER @ STC <br />MODEL <br />MODULE SPECIFICATION <br />HANWHA Q CELLS Q.PEAK DUO <br />BLK ML-G10+ 405 (405W) <br />OCPD CALCULATION <br />ALLOWABLE BACKFEED: <br />MAIN PANEL RATING = 225 A <br />MAIN BREAKER RATING = 200 A <br />120% RULE: = ((MAIN PANEL RATING * 1.2) - MAIN BREAKER RATING) <br />= ((225 A*1.2)-200 A) <br />= 70 A <br />ALLOWABLE BACKFEED = 70 A <br />INVERTER OVERCURRENT PROTECTION: <br />INVERTER OVERCURRENT PROTECTION = (MICROINVERTER O/P CURRENT * # OF MICROINVERTER <br /> * CONTINUOUS LOAD(1.25)) <br />= (1.21 * 21 *1.25) <br />= 31.76 A <br />PV BREAKER = 40 A ≥ 31.76 A <br />ALLOWABLE BACKFEED 70 A ≥ 40 A OF PV BREAKER <br />THE DESIGNED INTERCONNECTION MEETS THE 705.12(B)(3)(2) REQUIREMENTS. <br />TAG 1: (AC) <br /> REQUIRED CONDUCTOR AMPACITY(1.21 x 11 x 1.25) <br /> CORRECTED AMPACITY CALCULATION(0.87 x 1 x 30) <br />16.64 A < 26.1 A <br />TAG 2: (AC) <br /> REQUIRED CONDUCTOR AMPACITY(1.21 x 11 x 1.25) <br /> CORRECTED AMPACITY CALCULATION(0.87 x 0.8 x 40) <br />16.64 A < 27.84 A <br />TAG 3: (AC) <br /> REQUIRED CONDUCTOR AMPACITY(1.21 x 21 x1.25) <br /> CORRECTED AMPACITY CALCULATION(0.87 x 1 x 55) <br />31.76 A < 47.85 A <br />= 16.64 A <br />= 26.1 A <br />= 16.64 A <br />= 27.84 A <br />= 31.76 A <br />= 47.85 A <br />WIRE SIZE CALCULATIONS <br />AC WIRE SIZING CALCULATIONS BASED ON FOLLOWING EQUATIONS <br />REQUIRED CONDUCTOR AMPACITY: <br /> INVERTER OUTPUT CURRENT * #OF INVERTERS = MAX CURRENT PER 690.8(A)(1)(e)* 125% <br /> = MAX CURRENT PER 690.8(B)(1) <br />CORRECTED AMPACITY CALCULATIONS: <br /> DERATED CONDUCTOR AMPACITY PER 690.8(B)(2) = AMPACITY * TEMPERATURE DERATE FACTOR * <br /> CONDUIT FILL DERATE <br /> DERATED CONDUCTOR AMPACITY CHECK: MAX CURRENT PER 690.8(B)(1) < DERATED CONDUCTOR AMPACITY <br />1. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS <br />SUNLIGHT RESISTANT PER CEC 310.10(D). <br />2. CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE <br />SUITABLE FOR USE IN WET LOCATIONS PER CEC 310.10(C). <br />3. MAXIMUM DC/AC VOLTAGE DROP SHALL BE NO MORE THAN 2%. <br />4. ALL CONDUCTORS SHALL BE IN CONDUIT UNLESS OTHERWISE <br />NOTED. <br />5. BREAKER/FUSE SIZES PER CEC 240. <br />6. AC EQUIPMENT GROUNDING CONDUCTOR SIZED PER CEC <br />250.122. <br />7. THE AMBIENT TEMPERATURE CORRECTION FACTOR IS BASED <br />ON CEC 690.31(A). <br />8. THE AMBIENT TEMPERATURE ADJUSTMENT FACTOR IS BASED <br /> ON CEC 310.15(B)(1). <br />9. MAX SYSTEM VOLTAGE CORRECTION IS PER CEC 690.7. <br />10. CONDUCTORS ARE SIZED PER CEC TABLE 310.16. <br />1613 E Buffalo Ave <br />07/17/23