Laserfiche WebLink
HOMEOWNER: ALBERT LUU <br />ADDRESS: 1609 W. 11TH STREET UNIT #3 <br />SANTA ANA, CA 92703 <br />DATE: 11/29/22DATE: 11/29/22 <br />ECOSOLAR USA <br />ELECTRICAL LLC <br />13962 SEABOARD CIRCLE <br />GARDEN GROVE, CA 92840 <br />PH: 714.265.9077 DAVID Q HOANG C10 - 1045300 <br />SCO3E O) :OR. <br />INSTALL (6) Q.CELLS Q.PEAK DUO BLK-G6+ 340 AC <br />SOLAR ELECTRIC MODULES ON THE EXISTING 1ST <br />STORY COMPOSITION ROOF. INSTALL ASSOCIATED <br />MOUNTING HARDWARE, JUNCTION BOXES, CONDUIT, <br />CONDUCTORS AND GROUNDING. INSTALL (1) AC COMBINER, <br />(1)AC DISCONNECT, AND INSTALL OCPD IN SUB PANEL. <br />9ICI1 IT< 0A3 <br />LUU <br />RESIDENCE <br />S+EET I1'E; <br />PV0 <br />PV1 <br />PV2 <br />PV3 <br />ATTACHED <br />STRUCTURAL REPORT <br />NTS <br />COVER PAGE <br />SITE/ROOF PLAN, ELEVATION DETAIL <br />ELECTRIC LINE DRAWING, GROUNDING DETAIL <br />CALCULATIONS, SIGNS <br />MODULE, INVERTER, MOUNTING HARDWARE SPEC SHEETS, <br />1OTICE <br />A1 < C+A1*ES TO OR USES O ) T+ESE 'OCU0E1TS'RA:I1*S :IT+OUT T+E <br />:RITTE1 CO1SE1T O) -E11I)ER .E00E OR SCOTT +ARRIS ARE STRICTL< 3RO+I%ITE' <br />PV0 <br />PLANS PREPARED BY: <br />JENNIFER KEMME <br />PH: 909.748.1300 <br />*E1ERAL 1OTES <br />1. THIS SYSTEM COMPLIES WITH THE 2019 CRC, 2019 CBC, 2019 CFC, AND THE 2019 <br />CEC. <br />2. THE SYSTEM WILL NOT BE TURNED-ON UNTIL THE SERVING UTILITY COMPANY <br />HAS BEEN NOTIFIED. <br />3. THE INSTALLED SOLAR SYSTEM HAS A DISTRIBUTED WEIGHT LESS THAN 4 PSF. <br />4. THE CONCENTRATED LOAD FOR EACH VERTICAL SUPPORT IS LESS THAN 40 LBS. <br />5. ALL PV EQUIPMENT IS LISTED BY A RECOGNIZED TESTING LAB. INVERTERS ARE <br />UL 1741 COMPLIANT. <br />6. THE BACKFED BREAKER WILL BE LOCATED AT THE OPPOSITE END OF THE BUS <br />FROM THE MAIN BREAKER. <br />7. CONDUCTORS ARE 90° C RATED COPPER WIRE. <br />8. ANY CONDUCTORS EXPOSED TO SUNLIGHT ARE LISTED AS SUNLIGHT <br />RESISTANT. <br />9. IF DC CONDUCTORS ARE RUN INSIDE THE BUILDING, THEY WILL BE CONTAINED <br />IN A METAL RACEWAY. <br />10. ANY CONDUCTORS BETWEEN SEPARATE ARRAYS ON THE ROOF WILL BE <br />PROTECTED IN CONDUIT. <br />11. THE EQUIPMENT GROUNDING CONDUCTOR ON THE ROOF WILL BE PROTECTED <br />FROM PHYSICAL DAMAGE. IT WILL BE TUCKED NEATLY UNDER THE MODULES <br />AND RAILS AND SECURED IN PLACE. <br />12. THE MODULES WILL BE ATTACHED TO THE EQUIPMENT GROUNDING <br />CONDUCTOR IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. <br />13. ALL EXTERIOR CONDUIT, FITTINGS AND BOXES ARE RAIN-TIGHT AND APPROVED <br />FOR USE IN WET LOCATIONS. <br />14. CLEARANCES AROUND ALL ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN <br />ACCORDANCE WITH CEC 110.26. <br />15. SOLAR MODULES WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL OR <br />BUILDING ROOF VENTS. <br />16. IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE <br />GROUNDING ELECTRODE SYSTEM, A GROUNDING ELECTRODE SYSTEM WILL BE <br />INSTALLED PER CEC 250.50. THE ELECTRICAL SERVICE WILL BE BONDED TO THE <br />WATER AND GAS PIPING PER SECTION 250.104 OF THE CEC. <br />17. A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH CAL-OSHA <br />REGULATIONS. <br />89047PVR2 <br />3+OTO9OLTAIC SOLAR 3RO-ECT I1)OR0ATIO1 <br />SYSTEM SIZE: 2.040 kW (DC), 1.740 KW (AC) <br />MODULES: <br />ARRAY:INSTALLED WEIGHT = 2.9 PSF <br />ROOF COVERAGE = 120 SF, <br />ARRAYS COVER 10% OF TOTAL ROOF AREA <br />MOUNTING HARDWARE: UNIRAC SOLARMOUNT RAIL <br />UNIRAC FLASHKIT PRO ATTACHMENTS <br />5 16" STAINLESS STEEL LAG BOLTS @ <br />64" OC OR LESS WITH A MINIMUM OF <br />21 2" PENETRATION INTO ROOF RAFTERS <br />EXISTING ROOF INFO: 1 STORY, COMPOSITION SHINGLE <br />2 X 4 RAFTERS @ 16" OC <br />(6)Q.CELLS Q.PEAK DUO BLK-G6+ 340 AC <br />AC MODULES <br />PEAK POWER = 340 W <br />MAX OUTPUT CURRENT = 1.21 A <br />MAX OCPD = 20 A <br />MAX NUMBER IN SERIES = 13 <br />TEMP. COEFF. OF POWER = -0.27%/K <br />DIMENSIONS = 68.5" X 40.6" X 1.6" <br />WEIGHT = 47.2 LBS <br />The scope of the plans is for the installation <br />of the solar photovoltaic system only and the <br />approval is subject to compliance with all <br />applicable city and state codes and <br />regulations regarding construction. The <br />approval of the plans does not constitute any <br />certification of the accuracy, completeness, <br />or building permit status of the existing <br />buildings and structures as shown. <br />Bldg# 101113595 <br />Elec# 20178526 <br />Issued 01/24/23 <br />1609 W 11th St Unit <br />#301/25/23