Laserfiche WebLink
1805 S GARNSEY ST <br />(E) 200A MAIN SERVICE PANEL <br />WITH (E) 200A MAIN BREAKER <br />(E) UTILITY METER <br />(N) 30A NON FUSED <br />AC DISCONNECT <br />(N) ENPHASE IQ <br />COMBINER BOX 4 <br />(N) PV MODULES <br />SHEET NAME <br />SHEET NUMBER <br />PV-5 <br />PROJECT NAME <br />RI <br />C <br />A <br />R <br />D <br />O <br /> <br />T <br />O <br />R <br />R <br />E <br />S <br />18 <br />0 <br />5 <br /> <br />S <br /> <br />G <br />A <br />R <br />N <br />S <br />E <br />Y <br /> <br />S <br />T <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br />C <br />A <br />, <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br /> <br />U <br />S <br />A <br />AP <br />N <br /># <br /> <br />0 <br />1 <br />3 <br />2 <br />4 <br />2 <br />0 <br />7 <br />UT <br />I <br />L <br />I <br />T <br />Y <br />: <br /> <br />S <br />C <br />E <br />AH <br />J <br />: <br /> <br />C <br />I <br />T <br />Y <br /> <br />O <br />F <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />SHEET SIZE <br />ANSI B <br />11" X 17" <br />DEL MAR, CA 92014, USA <br />REVDATEDESCRIPTION <br />VERSION <br />UR10/13/2022INITIAL RELEASE <br />A01/19/2024REVISION <br />WARNING LABELS & <br />PLACARD <br />A <br />POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE <br />FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN <br />CAUTION ! <br />MULTIPLE SOURCES OF POWER <br />LABEL LOCATION: <br />EMT/CONDUIT RACEWAYS <br />(PER CODE: CEC690.31(D)(2) <br />NOTES AND SPECIFICATIONS: <br />x SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE <br />2022 ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS <br />ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE <br />LOCAL AHJ. <br />x SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS <br />USING EFFECTIVE WORDS, COLORS AND SYMBOLS. <br />x LABELS SHALL BE PERMANENTLY AFFIXED TO THE <br />EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND <br />WRITTEN. <br />x LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND <br />THE ENVIRONMENT INVOLVED. <br />x SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, <br />PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE <br />SPECIFIED. <br />x DO NOT COVER EXISTING MANUFACTURER LABELS. <br />ELECTRICAL SHOCK HAZARD <br />WARNING <br />20.30 <br />LABEL LOCATION: <br />AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF <br />INTERCONNECTION. <br />PER CODE(S): CEC 2022: 690.54 <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />SOLAR ELECTRIC <br />PV PANELS <br />LABEL LOCATION: <br />ON MAIN SERVICE PANEL. <br />PER CODE(S): 2022 CFC 605.11.3.1 & 2022 CFC 690.56(C) <br />4" <br />3" <br />PHOTOVOLTAIC AC DISCONNECT <br />MAIN PHOTOVOLTAIC <br />SYSTEM DISCONNECT <br />LABEL LOCATION: <br />MAIN SERVICE DISCONNECT / UTILITY METER <br />(PER CODE: CEC 690.13(B)) <br />LABEL LOCATION: <br />UTILITY SERVICE ENTRANCE/METER, INVERTER/DC <br />DISCONNECT IF REQUIRED BY LOCAL AHJ, OR OTHER <br />LOCATIONS (WITHIN 3') AS REQUIRED BY LOCAL AHJ. <br />PER CODE(S): CEC 2022: 690.56(C)(2) <br />! <br />WARNING <br />THE DISCONNECTION OF THE <br />GROUNDED CONDUCTOR(S) <br />MAY RESULT IN OVERVOLTAGE <br />ON THE EQUIPMENT <br />! <br />LABEL LOCATION: <br />COMBINER <br />PER CODE: CEC 690.31(E) <br />LABEL LOCATION: <br />AC DISCONNECT/BREAKER/ <br />POINT OF CONNECTION <br />(PER CODE: CEC 690.13(B) <br />PHOTOVOLTAIC <br />AC DISCONNECT <br />LABEL LOCATION: <br />MAIN SERVICE PANEL, INVERTER, <br />COMBINER, EMT <br />(IF APPLICABLE). <br />PER CODE(S): CEC 2022: CEC 706.15 <br />(C)(4) & CEC 690.13(B) <br />LABEL LOCATION: <br />POINT OF INTERCONNECTION <br />PRODUCTION METER <br />CEC 705.12(C)/705.12(D)(3) & CEC 690.59) <br />! <br />THIS EQUIPMENT FED BY <br />MULTIPLE SOURCES: <br />TOTAL RATING OF ALL OVERCURRENT <br />DEVICES EXCLUDING MAIN POWER <br />SUPPLY SHALL NOT EXCEED <br />AMPACITY OF BUSBAR <br />WARNING <br />LABEL LOCATION: <br /> POINTS OF CONNECTION/BREAKER <br /> CODE : CEC 705.12(B)(3)(3) <br />LABEL LOCATION: <br />SERVICE PANEL IF SUM OF BREAKERS EXCEEDS <br />PANEL RATING <br />CEC 705.12 (B)(3)(2) <br />! <br />LABEL LOCATION: <br />MSP (PER CODE: CEC 705.12 (D) & CEC 690.59 <br />CAUTION <br />PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED <br />! <br />WARNING <br />POWER SOURCE OUTPUT <br />CONNECTION <br />DO NOT RELOCATE THIS <br />OVERCURRENT DEVICE <br />! <br />CSLB 1060243 C10LB 1 24 1 <br />1805 S Garnsey St <br />2/9/2024