Laserfiche WebLink
SCOPE: <br />2.40 KW DC Roof Mounted <br />PV Electrical System <br />6 - Ureco 400W PV Modules <br />6 - IQ8+ Enphase Microinverters <br />DATE:03/10/2023 <br />SCALE:AS NOTED PAPER SIZE:17"x11" <br />CUSTOMER INFORMATION <br />BUILDING INFO: <br />ONE STORY BUILDING <br />ROOF TYPE: COMPOSITION SHINGLE <br />ROOF STRUCTURE: <br />2''X4'' RAFTERS 24'' O/C <br />MOUNTING SYSTEM: <br />IRONRIDGE RACKING <br />PARCEL NUMBER: 10936105 <br />LOT AREA: 6,272 SQFT <br />LIVING AREA: 1,139 SQFT <br />COMPANY NAME: SKYSOLARPRO <br />ANDREY LITVINOV: #867980 TYPE: C10 <br />DATE: 11/30/2023 <br />ADDRESS: 11208 DONA LOLA DRIVE <br />STUDIO CITY, CA 91604 <br />PHONE: (323) 428-4892 <br />SIGNATURE <br />NAME: PET MARTINEZ <br />ADDRESS: 1705 W CUBBON ST, <br />SANTA ANA, CA 92703 <br />CITY OF SANTA ANA <br />UTILITY: SCE <br />PV-6 <br />CAUTION <br />POWER TO THIS BUILDING IS ALSO SUPPLIED <br />FROM THE FOLLOWING SOURCES WITH <br />DISCONNECTS LOCATED AS SHOWN: <br />PHOTOVOLTAIC ARRAY <br />14 <br />METER <br />MAIN SERVICE <br />PANEL <br />7 <br />9 <br />12 <br />13 <br />AC <br />DISCONNECT <br />* if applicable <br />7 <br />SUB-PANEL <br />* if applicable <br />7 <br />9 <br />8 <br />11 <br />10 <br />7 <br />9 <br />6 <br />PV SUB-PANEL <br />* if applicable <br />8 <br />11 <br />10 <br />INVERTER <br />*if applicable <br />3 <br />INTEGRATED <br />DC DISCONNECT <br />4 5 <br />J BOX <br />1 2 <br />8 <br />10 <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE "OFF" <br />POSITION TO SHUT <br />DOWN PV SYSTEM AND <br />REDUCE SHOCK <br />HAZARD IN THE ARRAY <br />SOLAR ELECTRIC <br />PV PANELS <br />1 <br />(TO BE LOCATED ON <br />SUB-PANEL ONLY <br />WHEN SUB-PANEL IS <br />DEDICATED FOR PV ONLY) <br />PV SUB-PANEL ONLY <br />CAUTION <br />AUTHORIZED SOLAR <br />PERSONNAL ONLY! <br />WARNING! <br />ELECTRIC SHOCK HAZARD. <br />IF GROUND FAULT IS INDICATED, <br />NORMALLY GROUNDED <br />CONDUCTORS MAY BE <br /> UNGROUNDED AND ENERGIZED. <br />RAPID SHUT DOWN SWITCH <br />FOR SOLAR PV SYSTEM <br />705.12 (D)(3) <br />CAUTION <br />DUAL POWER SOURCE SECOND <br />SOURCE IS PHOTOVOLTAIC SYSTEM <br />AC DISCONNECT <br />AC PHOTOVOLTAIC POWER SOURCE <br />RATED AC OUTPUT CURRENT: 7.3A MAX <br />NOMINAL AC OPERATING VOLTAGE: 240 Vac <br />THIS PANEL FED BY <br />MULTIPLE SOURCES <br />(UTILITY & SOLAR) <br />WARNING! <br />ELECTRIC SHOCK HAZARD. <br />TERMINALS ON BOTH THE LINE AND <br />LOAD SIDES MAY BE ENERGIZED IN <br />THE OPEN POSITION. <br />ALL SIGNAGE/LABELS SHALL BE IN THE FOLLOWING FORMAT: <br />1. WHITE LETTERING ON A RED BACKGROUND AND WEATHER RESISTANT <br />2. MINIMUM 3/8" LETTER HEIGHT <br />3. ALL LETTERS SHALL BE CAPITALIZED <br />4. ARIAL OR SIMILAR FONT, NON-BOLD <br />5. SHALL BE IN ACCORDANCE WITH APPROPRIATE SECTIONS, <br />TABLES AND ARTICLES OF THE NEC, IFC. <br />(STICKER TO BE LOCATED ON CONDUIT WITH DC CURRENT EVERY 4' <br />HORIZONTALLY OR 10' VERTICALLY AND 1' FROM EACH SIDE OF A BEND) <br />WARNING: PHOTOVOLTAIC POWER SOURCE 2 <br />14 <br />3 4 <br />5 <br />6 <br />7 <br />(STICKER LOCATED <br />INSIDE PANEL <br />NEXT TO SOLAR BREAKER) <br />(STICKER LOCATED INSIDE PANEL <br />BELOW PV BREAKER) <br />PV LOAD CENTER SIZED FOR PV <br />BREAKERS ONLY OR RENDERED UNABLE <br />TO ACCEPT ANY ADDITIONAL LOADS. <br />SOLAR <br />WARNING <br />INVERTER OUTPUT CONNECTION. DO NOT <br />RELOCATE THIS OVERCURRENT DEVICE <br />9 <br />10 <br />11 <br />8 <br />(STICKER LOCATED <br />ON THE PV SUB PANEL) <br />12 13 <br />CODE REQUIRED SIGNAGEPHOTOVOLTAIC <br />ARRAY ON ROOF <br />DC DISCONNECT <br />DC PHOTOVOLTAIC POWER SOURCE <br />RATED MAX POWER POINT CURRENT- 12.84 AMPS <br />RATED MAX POWER POINT VOLTAGE- 31.17 VOLTS <br />MAXIMUM SYSTEM VOLTAGE- 41.66 VOLTS <br />SHORT CIRCUIT CURRENT- 13.68 AMPS <br />SERVICE POINT & <br />UTILITY METERING <br />IQ COMBINER BOX <br />W Cubbon St <br />SOLAR DISCONNECT <br />1705 W Cubbon St <br />04/14/23