Laserfiche WebLink
The Enphase IQ System Controller 2 connects the <br />home to grid power, the IQ Battery system, and solar <br />PV. It provides microgrid interconnection device <br />(MID) functionality by automatically detecting and <br />seamlessly transitioning the home energy system <br />from grid power to backup power in the event of a grid <br />failure. It consolidates interconnection equipment into <br />a single enclosure and streamlines grid independent <br />capabilities of PV and storage installations by <br />providing a consistent, pre-wired solution for <br />residential applications. <br />Enphase <br />IQ System Controller 2 <br />To learn more about Enphase offerings, visit enphase.com <br />Data Sheet <br />Enphase Energy System <br />Reliable <br />• Durable NEMA type 3R enclosure <br />• Ten-year limited warranty <br />Smart <br />• Controls safe connectivity to the grid <br />• Automatically detects grid outages <br />• Provides seamless transition to backup <br />Simple <br />• Connects to the load or service equipment¹ side of the main <br />load panel <br />• Centered mounting brackets support single stud mounting <br />• Supports conduit entry from the bottom, bottom left side, <br />and bottom right side <br />• Supports whole home and partial home backup and <br />subpanel backup <br />• Up to 200A main breaker support <br />• Includes neutral-forming transformer for split phase <br />120/240V backup operation <br />• IQ System Controller supports backward compatibility with <br />older generation of PV microinverters (M215, M250 and S <br />series), making it simple for home owners to upgrade their <br />systems <br />• Easy integration with generator from major manufacturers <br />1. IQ System Controller 2 is not suitable for use as service equipment in Canada. <br />To learn more about Enphase offerings, visit enphase.com <br />© 2021 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ System Controller 2, and other names are the trademarks of Enphase <br />Energy, Inc. Data subject to change. 10-20-2021 <br />MODEL NUMBER <br />EP200G101-M240US01 Enphase IQ System Controller 2 with neutral-forming transformer (NFT), Microgrid Interconnect Device (MID), <br />breakers, and screws. Streamlines grid-independent capabilities of PV and battery installations. <br />ACCESSORIES and REPLACEMENT PARTS <br />EP200G-NA-XA-E3 Replacement IQ System Controller 2 printed circuit board <br />EP200G-NA-HD-200A Eaton type BR circuit breaker hold-down screw kit, BRHDK125 <br />CT-200-SPLIT 200 A split core current transformers for Generator metering (+/- 2.5%) <br />Circuit breakers (as needed)²,³ <br />• BRK-100A-2P-240V : Main breaker, 2 pole, 100A, 25kAIC, CSR2100 <br />• BRK-125A-2P-240V: Main breaker, 2 pole, 125A, 25kAIC, CSR2125N <br />• BRK-150A-2P-240V: Main breaker, 2 pole, 150A, 25kAIC, CSR2150N <br />• BRK-175A-2P-240V: Main breaker, 2 pole, 175A, 25kAIC, CSR2175N <br />• BRK-200A-2P-240V: Main breaker, 2 pole, 200A, 25kAIC, CSR2200N <br />Not included, must order separately: <br />• BRK-20A-2P-240V-B: Circuit breaker, 2 pole, 20A, 10kAIC, BR220B <br />• BRK-30A-2P-240V: Circuit breaker, 2 pole, 30A, 10kAIC, BR230B <br />• BRK-40A-2P-240V: Circuit breaker, 2 pole, 40A, 10kAIC, BR240B <br />• BRK-60A-2P-240V: Circuit breaker, 2 pole, 60A, 10kAIC, BR260 <br />• BRK-80A-2P-240V: Circuit breaker, 2 pole, 80A, 10kAIC, BR280 <br />EP200G-HNDL-R1 IQ System Controller 2 installation handle kit (order separately) <br />EP200G-LITKIT <br />BRK-20A40A-2P-240V 2 pole, 20A/40A, 10kAIC, BQC220240 <br />ELECTRICAL SPECIFICATIONS <br />Assembly rating Continuous operation at 100% of its rating <br />Nominal voltage / range (L-L) 240 VAC / 100 - 310 VAC <br />Voltage measurement accuracy ±1% V nominal (±1.2V L-N and ±2.4V L-L) <br />Auxiliary contact for load control, excess PV control, and generator two-wire control 24V, 1A <br />Nominal frequency / range 60 Hz / 56 - 63 Hz <br />Frequency measurement accuracy ±0.1 Hz <br />Maximum continuous current rating 160A <br />Maximum input overcurrent protection device 200A <br />Maximum output overcurrent protection device 200A <br />Maximum overcurrent protection device rating for Generator circuit 80A <br />Maximum overcurrent protection device rating for storage branch circuit <br />(the storage branch circuit can be replaced with PV) <br />80A <br />Maximum overcurrent protection device rating for IQ8 PV combiner branch circuit 80A <br />Neutral Forming Transformer (NFT) • Breaker rating (pre-installed): 40A between L1 and Neutral; 40A between L2 and Neutral <br />• Continuous rated power: 3600VA <br />• Maximum continuous unbalance current: 30A @ 120V <br />• Peak rated power: 8800VA for 30 seconds <br />• Peak unbalanced current: 80A @ 120V for 30 seconds <br />MECHANICAL DATA <br />Dimensions (WxHxD) 50cm x 91.6cm x 24.6cm (19.7 in x 36 in x 9.7 in) <br />Weight 39.4 kg (87 lbs) <br />Ambient temperature range -40º C to +50º C (-40º F to 122º F) <br />Cooling Natural convection, plus heat shield <br />Enclosure environmental rating Outdoor, NEMA type 3R, polycarbonate construction <br />Altitude To 2500 meters (8200 feet) <br />WIRE SIZES <br />Connections <br />(All lugs are rated to 90C) <br />• Main lugs and backup load lugs <br />• CSR breaker bottom wiring lugs <br />• BR breakers (wire provided) <br />• AC combiner lugs, Encharge lugs, and generator lugs <br />• Neutral (large lugs) <br />Cu/Al: 1 AWG – 300 KCMIL <br />Cu/Al: 2 AWG – 300 KCMIL <br />6 AWG <br />14 AWG – 2 AWG <br />Cu/Al: 6 AWG - 300 KCMIL <br />Neutral and ground bars Large holes (5/16-24 UNF) <br />Small holes (10-32 UNF) <br />14 AWG – 1/0 AWG <br />14 AWG – 6 AWG <br />COMPLIANCE <br />Compliance UL 1741, UL 1741 SA, UL 1741 PCS, UL1998, UL869A , UL67 , UL508 UL50E <br />CSA 22.2 No. 107.1, 47 CFR, Part 15, Class B, ICES 003, AC156. <br />IQ System Controller 2 is approved for Use as Service Equipment in the United States . <br />2. Compatible with BRHDK125 Hold-Down Kit to comply with 2017 NEC 710.15E for back-fed circuit breakers. <br />3. The IQ System Controller 2 is rated 22 kAIC <br />4. Not included. Installer must provide properly rated breaker per circuit breaker list above. <br />5. Sections from these standards were used during the safety evaluation and included in the UL 1741 listing. <br />Enphase IQ System Controller 2 <br />1817 W Meriday Ln- <br />201819032/22/2024