Laserfiche WebLink
JB <br />JB <br />MSP RSD <br />SUB <br />ACDESS IQSCCB <br />SUB <br />PV - 5.0 <br />SIGNAGE <br />DATE: <br />SHEET NAME: <br />SHEET NUMBER: <br />DESIGNED BY: <br />DATE/DESIGNERREV. <br />1 <br />2 <br />3 <br />CUSTOMER INFORMATION: <br />SERGIO SEGURA <br />1817 MERIDAY LN <br />SANTA ANA, CA 92706 <br />(714) 904-4946 <br />12/12/2023 <br />TDAUPRAT <br />PVDC ­ 210211 <br />- <br />- <br />- <br />THIS EQUIPMENT FED BY <br />MULTIPLE SOURCES TOTAL <br />RATING OF ALL OVERCURRENT <br />DEVICES EXCLUDING MAIN POWER <br />SUPPLY SHALL NOT EXCEED <br />AMPACITY OF BUSBAR <br />WARNING <br />LABEL LOCATION: <br /> POINTS OF CONNECTION/BREAKER <br />CODE: CEC 705.12(B)(3)(3) <br />! <br />CAUTION <br />TURN RAPID SHUTDOWN SWITCH TO OFF POSITION TO SHUT DOWN <br />PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY <br />"WARNING" <br /> PHOTOVOLTAIC ARRAY <br />DISCONNECTION OF NEUTRAL OR GROUNDED CONDUCTORS MAY RESULT IN <br />OVERVOLTAGE ON ARRAY OR INVERTER. <br />WARNING <br />POWER SOURCE OUTPUT <br />CONNECTION <br />DO NOT RELOCATE THIS <br />OVERCURRENT DEVICE <br />! <br />   WARNING DUAL POWER SOURCE <br />SECOND SOURCE IS PHOTOVOLTAIC SYSTEM <br />LABEL LOCATION: <br />EMT/CONDUIT RACEWAYS <br />(PER CODE: CEC690.31(D)(2) <br />PHOTOVOLTAIC POWER SOURCE <br />LABEL LOCATION: <br />POINT OF INTERCONNECTION <br />PRODUCTION METER <br />CEC 705.12(B)(3)(3) & CEC 690.59) <br />ELECTRICAL SHOCK HAZARD <br />WARNING <br />TERMINALS ON LINE AND LOAD <br />SIDES MAY BE ENERGIZED IN <br />THE OPEN POSITION <br />LABEL LOCATION: <br />INVERTER(S), AC DISCONNECT(S), AC <br />COMBINER PANEL (IF APPLICABLE). <br />PER CODE(S): CEC 2022: CEC 706.15 <br />(C)(4) & CEC 690.13(B) <br />LABEL LOCATION: <br />AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM <br />POINT OF INTERCONNECTION. <br />PER CODE(S): CEC 2022: 690.54 <br />LABEL LOCATION: <br />ON OR NO MORE THAT 1 M (3 FT) FROM THE <br />SERVICE DISCONNECTING MEANS TO <br />WHICH THE PV SYSTEMS ARE CONNECTED. <br />PER CODE(S): CEC 2022: IFC 690.56(C) <br />! <br />MAIN PHOTOVOLTAIC <br />SYSTEM DISCONNECT <br />LABEL LOCATION: <br />MAIN SERVICE DISCONNECT / UTILITY METER <br />(PER CODE: CEC 690.13(B)) <br />PHOTOVOLTAIC <br />AC DISCONNECT <br />LABEL LOCATION: <br />AC DISCONNECT CEC 690.13(B) <br />LABEL LOCATION: <br />MSP (PER CODE: CEC <br />705.12(D) & CEC 690.59 <br />CAUTION <br />PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED <br />! <br />LABEL LOCATION: <br />SERVICE PANEL IF SUM OF BREAKERS <br />EXCEEDS PANEL RATING <br />LABEL LOCATION: <br />UTILITY SERVICE ENTRANCE/METER, <br />INVERTER/DC DISCONNECT IF REQUIRED <br />BY LOCAL AHJ, OR OTHER LOCATIONS AS <br />REQUIRED BY LOCAL AHJ. <br />PER CODE(S): CEC 2022: 690.56(C)(2) <br />RAPID SHUTDOWN SWITCH <br />FOR SOLAR PV SYSTEM! <br />WARNING <br />THE DISCONNECTION OF THE <br />GROUNDED CONDUCTOR(S) <br />MAY RESULT IN OVERVOLTAGE <br />ON THE EQUIPMENT <br />! <br />LABEL LOCATION: <br />INVERTER <br />PER CODE: CEC 690.31(E) <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />SOLAR ELECTRIC <br />PV PANELS <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE "OFF" <br />POSITION TO SHUT DOWN <br />PV SYSTEM AND REDUCE <br />SHOCK HAZARD IN THE <br />ARRAY. <br />CEC 705.12 (B)(3)(2) <br />PHOTOVOLTAIC SYSTEM AC DISCONNECT <br />RATED AC OPERATING CURRENT 15.73 AMPS <br />AC NOMINAL OPERATING VOLTAGE 240 VOLTS <br />x________________ <br />JOHN RADLEIGH <br />VOLTAIC CONSTRUCTION, <br />LLC25186 HANCOCK AVE UNIT <br />230 MURRIETA, CA 92562 <br />(310) 709-0059 <br />CONSTRUCTION@VOLTAICNOW.COM <br />CSLB# 1096383 (B/C10) <br />YOU ARE HERE <br />MAIN SERVICE PANEL <br />RAPID SHUTDOWN DEVICEIQ COMBINER <br />IQ SYSTEM CONTROLLER 2 <br />AC DISCONNECT <br />BACKUP LOAD PANEL <br />ENPHASE IQ <br />BATTERY 10T <br />PV MODULES <br />1817 W Meriday Ln- <br />201819032/22/2024