My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1819 N Alona St - Plan
PBA
>
Building
>
ProjectDox
>
M
>
Main St
>
2500 N Main St
>
1819 N Alona St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 11:59:54 AM
Creation date
6/1/2025 11:59:45 AM
Metadata
Fields
Template:
Plan
Permit Number
10116836
20181097
Full Address
2500 N Main St
1819 N Alona St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
DESIGNER: TAYLOR BICKFORD <br />NEW PV SYSTEM: 5200 DC / 3800 AC <br />Mauricio Mendoza <br />1819 Alona St, Santa Ana, CA 92706 <br />APN: 00103401 <br />9/11/2023DATE: <br />TIME:03:46 PM <br />REVISION:DATE:DESCRIPTION: <br />DRAWING TITLE: <br />DRAWING PAGE: <br />SCALE: <br />DESIGNER SIGNATURE: <br />NOTES SHEET <br />P2 <br />1.RESIDENTIAL ROOF MOUNTED PHOTOVOLTAIC <br />SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH <br />THE MANUFACTURES SPECIFICATIONS AND THE 2022 <br />CALIFORNIA RESIDENTIAL CODE, SECTIONS R314, R909 <br />AND R918, 2022 CALIFORNIA ELECTRICAL CODE AND <br />2022 CALIFORNIA FIRE CODE. <br />2.CONTRACTORS SHALL BE PRESENT DURING ALL <br />INSPECTIONS. <br />3.THE ROOF ACCESS POINT REQUIRING A LADDER SHALL <br />NOT BE LOCATED OVER A WINDOW, DOOR OR <br />LOCATED WHERE IT CONFLICTS WITH OVERHEAD <br />OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS <br />[CRC 324.7.1]. <br />4.A LADDER SHALL BE PROVIDED AND SECURED TO THE <br />STRUCTURE AT THE APPROVED ROOF ACCESS POINT <br />PER NOT "C" ABOVE WITH A CAL OSHA APPROVED <br />DEVICE DURING ALL INSPECTIONS. <br />5.EXISTING PLUMBING VENTS, SKYLIGHTS, EXHAUST <br />OUTLETS, VENTILATION'S INTAKE AIR OPENINGS <br />SHALL NOT BE COVERED BY THE SOLAR <br />PHOTOVOLTAIC SYSTEM. <br />6.ALL EQUIPMENT SHALL BE LISTED AND LABELED BY A <br />RECOGNIZED ELECTRICAL TESTING LABORATORY AND <br />INSTALLED PER THE LISTING REQUIREMENTS AND THE <br />MANUFACTURER'S INSTRUCTIONS. [NEC 690.4(D)] <br />7.ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED, <br />INCLUDING ALL ROOF MOUNTED TRANSITION BOXES <br />AND SWITCHES. <br />8.CONTACT THE SERVICING UTILITY BEFORE POWERING <br />ON THE PHOTOVOLTAIC SYSTEM <br />9.ALL WORK SHALL COMPLY WITH APPLICABLE, LOCAL, <br />MUNICIPAL CODES, AND TO MANUFACTURERS' <br />LISTINGS AND INSTALLATION INSTRUCTIONS. THE PV <br />SOLAR SYSTEM WILL BE INTERCONNECTED AND <br />OPERATED IN PARALLEL WITH THE UTILITY <br />ELECTRICAL GRID PER THE REQUIREMENTS OF THE <br />UTILITY AND APPLICABLE CODES. THE PV SOLAR <br />SYSTEM IS DESIGNED IN COMPLIANCE WITH CEC 690.12 <br />(RAPID SHUTDOWN). <br />JURISDICTION NOTES ELECTRICAL NOTES <br />CONSTRUCTION NOTES <br />UTILITY NOTES <br />1.ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE <br />MANUFACTURER'S INSTALLATION INSTRUCTIONS. <br />2.ALL OUTDOOR EQUIPMENT SHALL BE RAIN TIGHT WITH MINIMUM NEMA 3R <br />RATING. <br />3.ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. <br />4.THE SOLAR INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING OR <br />MECHANICAL VENTS. <br />5.A LADDER WILL BE IN PLACE FOR INSPECTIONS IN COMPLIANCE WITH OSHA <br />REGULATIONS. <br />6.MODULE MOUNTING STRUCTURE WILL BE TIED DIRECTLY INTO STRUCTURAL <br />ELEMENTS OF SINGLE FAMILY DWELLING ROOF TRUSSES / RAFTERS OR BEAMS <br />ACCORDING TO MOUNTING STRUCTURE DIRECTIONS. <br />7.ROOF COVERING PENETRATIONS SHALL BE DESIGNED, INSTALLED AND <br />MAINTAINED IN ACCORDANCE WITH BUILDING CODE AND THE APPROVED <br />MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERINGS SHALL <br />SERVE TO PROTECT THE BUILDING STRUCTURE. <br />8.CONDUIT, WIRING SYSTEMS, AND RACEWAYS FOR PHOTOVOLTAIC CIRCUITS <br />SHALL BE LOCATED AS CLOSE AS POSSIBLE TO THE RIDGE, HIP, OR VALLEY. THIS <br />EQUIPMENT SHALL ALSO BE LOCATED AS CLOSE AS POSSIBLE TO AN OUTSIDE <br />WALL TO REDUCE TRIP HAZARDS AND MAXIMIZE VENTILATION OPPORTUNITIES. <br />9.MODULES MUST HAVE 6" CLEARANCE FROM ALL VENTS AND OBSTRUCTIONS. <br />CODE REFERENCES <br />GENERAL NOTES <br /> <br />JURISDICTION STAMPS: <br />BETTER EARTH ELECTRIC INC. <br />16720 MARQUARDT AVE CERRITOS <br />CERRITOS, CA 90703 <br />PHONE #: (888) 373-9379 <br />LIC #: C10-1024460 <br />1.PV SOURCE CIRCUIT(S) ARE TO BE <br />SUNLIGHT-RESISTANT PV-WIRE AS <br />PERMITTED BY CEC 690.31(B). <br />2.ALL DIRECT CURRENT CIRCUITS ARE TO BE <br />INSTALLED IN METAL RACEWAY FROM THE <br />POINT OF PENETRATION OF THE SURFACE OF <br />THE BUILDING OR STRUCTURE TO THE MAIN <br />SERVICE PANEL AS MANDATED BY CEC <br />690.31(E). <br />3.WEATHERPROOF J-BOX – NEMA 3R. <br />4.ROOFTOP CONDUIT SHALL BE A MINIMUM <br />OF 7/8" ABOVE THE ROOF SURFACE. <br />5.ALL WORK SHALL COMPLY WITH THE 2022 <br />CALIFORNIA ELECTRICAL CODE (C.E.C.) AND <br />ALL OTHER LOCAL CODES AS APPROVED BY <br />THE AUTHORITY HAVING JURISDICTION. <br />2022 CALIFORNIA ELECTRICAL CODE <br />2022 CALIFORNIA BUILDING CODE <br />2022 CALIFORNIA RESIDENTIAL CODE <br />2022 CALIFORNIA FIRE CODE <br />2022 CALIFORNIA MECHANICAL CODE <br />2022 CALIFORNIA GREEN CODE <br />2022 CALIFORNIA PLUMBING CODE <br />2022 CALIFORNIA ENERGY CODE <br /> <br />This item has been digitally signed <br />and sealed on Sep 14, 2023 <br />1819 N Alona St <br />10/17/2023