Laserfiche WebLink
Roof Framing Checks: <br />LC1: D+S <br />Force Checks: <br />Applied Moment (lb-ft) = <br />Applied Shear (lbs) = <br />Allowable Moment (lb-ft) = <br />Allowable Shear (lbs) = <br />Moment DCR = <br />Shear DCR = <br />LC2: D+0.6W <br />Applied Moment (lb-ft) = <br />Applied Shear (lbs) = <br />Allowable Moment (lb-ft) = <br />Allowable Shear (lbs) = <br />Moment DCR = <br />Shear DCR = <br />LC3: D+0.75(S+0.6W) <br />Applied Moment (lb-ft) = <br />Applied Shear (lbs) = <br />Allowable Moment (lb-ft) = <br />Allowable Shear (lbs) = <br />Moment DCR = <br />Shear DCR = <br />LC4: 0.6D+0.6W <br />Applied Moment (lb-ft) = <br />Applied Shear (lbs) = <br />Allowable Moment (lb-ft) = <br />Allowable Shear (lbs) = <br />Moment DCR = <br />Shear DCR = <br />Page 5 of 8 <br />Celia Meneses <br />487.0 <br />138.0 <br />975.0 <br />1138.0 <br />0.5 <br />0.122 <br />559.0 <br />148.0 <br />975.0 <br />1138.0 <br />0.574 <br />0.13 <br />Roof 1 Roof 2 <br />958.0 <br />272.0 <br />1357.0 <br />1584.0 <br />0.706 <br />0.172 <br />1099.0 <br />292.0 <br />1357.0 <br />1584.0 <br />0.81 <br />0.184 <br />840.0 <br />239.0 <br />1357.0 <br />1584.0 <br />0.619 <br />0.151 <br />964.0 <br />256.0 <br />1357.0 <br />1584.0 <br />0.711 <br />0.161 <br />1760 Chicago Ave Suite J13, Riverside, CA 92507 (951) 405-1733info@currentrenewableseng.com <br />763.0 <br />217.0 <br />1357.0 <br />1584.0 <br />0.562 <br />0.137 <br />876.0 <br />232.0 <br />1357.0 <br />1584.0 <br />0.645 <br />0.147 <br />1617 W Carriage <br />Dr05/23/23