My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1617 W Carriage Dr - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Carriage Dr
>
1617 W Carriage Dr
>
1617 W Carriage Dr - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:00:08 PM
Creation date
6/1/2025 11:59:46 AM
Metadata
Fields
Template:
Plan
Permit Number
20179510
101114921
101116057
Full Address
1617 W Carriage Dr
Document Relationships
101114921 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Carriage Dr\1617 W Carriage Dr
101116057 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Carriage Dr\1617 W Carriage Dr
20179510 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Carriage Dr\1617 W Carriage Dr
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
SHEET NAME <br />SHEET NUMBER <br />PV-4 <br />PROJECT NAME <br />CE <br />L <br />I <br />A <br /> <br />M <br />E <br />N <br />E <br />S <br />E <br />S <br />1 <br />6 <br />1 <br />7 <br /> <br />W <br /> <br />C <br />A <br />R <br />R <br />I <br />A <br />G <br />E <br /> <br />D <br />R <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />, <br /> <br />U <br />S <br />A <br />AP <br />N <br /># <br /> <br />4 <br />1 <br />2 <br />0 <br />1 <br />1 <br />1 <br />2 <br />UT <br />I <br />L <br />I <br />T <br />Y <br />: <br /> <br />S <br />C <br />E <br />AH <br />J <br />: <br /> <br /> C <br />I <br />T <br />Y <br /> <br />O <br />F <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />SHEET SIZE <br />ANSI B <br />11" X 17" <br />DEL MAR, CA 92014, USA <br />REVDATE DESCRIPTION <br />VERSION <br />UR03/13/2023 INITIAL RELEASE <br />DESIGN SUPPORT DAY OF INSTALL: <br />CHAT.POWUR.COM <br />ELECTRICAL LINE <br />DIAGRAM WITH <br />CALCULATION <br />ELECTRICAL LINE DIAGRAM WITH CALCULATION <br />SCALE: NTS1 <br />#2 #1#08 <br />DC <br />AC <br />#2 #1#07 <br />08 MODULES CONNECTED IN STRING #1 <br />07 MODULES CONNECTED IN STRING #2 <br />(N) SOLAREDGE SE5000H-US (240V) <br />OUTPUT: 240 VAC,21A <br />99% CEC WEIGHTED EFFICIENCY <br />NEMA 3R, UL LISTED, INTERNAL GFDI <br />WITH INTEGRATED DC DISCONNECT <br />G <br />(N) JUNCTION BOX <br />A <br />B <br />AMBIENT TEMPERTURE SPECIFICATIONS <br />RECORD <br />LOW TEMP <br />AMBIENT TEMP <br />(HIGH TEMP 2%) <br />CONDUCTOR <br />TEMPERATURE <br />RATE (ON <br />ROOF) <br />CONDUCTOR <br />TEMPERATURE <br />RATE (OFF <br />ROOF) <br />2°31° 90°75° <br />D <br />L <br />100A <br />BI-DIRECTIONAL <br />UTILITY METER <br />1-PHASE, 3-W, <br />120V/240V, 60Hz <br />(E) MAIN BREAKER <br />100A/2P, 240V <br />(E) 100A MAIN <br />SERVICE <br />PANEL,120/240V <br />EXISTING <br />GROUNDING <br />SYSTEM <br />G <br />(N) 125A SUB <br />PANEL WITH (N) <br />100 MAIN BREAKER <br />G <br />100A <br />(N) LUG KIT <br />NOTE: <br />1. MOVE ALL EXISTING LOADS FROM (E) MAIN <br />SERVICE PANEL TO (N) SUB-PANEL <br />2. DO NOT INSTALL ADDITIONAL LOADS IN MAIN <br />SERVICE PANEL <br />SOLAREDGE POWER OPTIMIZER P505 <br />RATED DC INPUT POWER - 505 WATTS <br />MAXIMUM INPUT VOLTAGE - 83 VDC <br />MPPT RANGE - 12.5 TO 83 VDC <br />MAXIMUM INPUT CURRENT - 14 ADC <br />MAXIMUM OUTPUT CURRENT - 17.5 ADC STRING <br />LIMITATIONS - 6 TO 25 OPTIMIZERS, <br />5700 WATTS STC PER STRING MAXIMUM <br />SOLAREDGE OPTIMIZERS HAVE INTEGRATED <br />RAPID SHUT DOWN <br />UTILITY PROVIDER: <br />MAIN SERVICE VOLTAGE: <br />MAIN PANEL BRAND: <br />MAIN SERVICE PANEL: <br />MAIN CIRCUIT BREAKER RATING: <br />MAIN SERVICE LOCATION: <br />SERVICE FEED SOURCE: <br />SCE <br />240V <br />CUTLER-HAMMER <br />(E) 100 A <br />(E) 100 A <br />SOUTH-WEST <br />SERVICE INFO. <br />UNDERGROUND <br />NOTE: <br />3/4" OR GREATER EMT CONDUIT <br />RUN (7/8" ABOVE ROOF) <br />WIRE TAG CONDUIT WIRE QTY WIRE <br />GAUGE WIRE TYPE TEMP. <br />RATING <br />WIRE <br />AMPACITY (A) <br />TEMP. <br />DERATE <br />CONDUIT FILL <br />DERATE <br />DERATED <br />AMPACITY <br />(A) <br />ISC <br />DESIGN <br />CURRENT <br />(A) <br />GROUND <br />SIZE <br />GROUND <br />WIRE TYPE <br />A OPEN AIR 4 10 AWG PV-WIRE 90°C 40 0.96 1.0 38.40 15 15 06 AWG BARE CU <br />GND <br />B 3/4" EMT 4 10 AWG THWN-2 90°C 40 0.96 0.8 30.72 15 15 10 AWG THWN-2 <br />C 3/4" EMT 3 10 AWG THWN 75°C 35 0.94 1.0 32.90 21 21 10 AWG THWN <br />D 3/4" EMT 3 6 AWG THWN 75°C 65 0.94 1.0 61.10 21 21 8 AWG THWN <br />SOLAR MODULE SPECIFICATIONS <br />MANUFACTURER / MODEL # VMP IMP VOC ISC <br />TEMPERATURE <br />COEFFICIENT <br />OF Voc <br /># OF MODULES <br />HANWHA Q CELLS Q.PEAK DUO <br />BLK ML-G10.A+ (400W)37.13 10.77 45.30 11.14 -0.27%/°C 15 <br />MODULE DIMENSION 74" L x 41.1" W x 1.26"D <br />INVERTER SPECIFICATIONS <br />MANUFACTURER / MODEL # QUANTITY NOMINAL OUTPUT <br />VOLTAGE <br />NOMINAL OUTPUT <br />CURRENT <br />SOLAREDGE SE5000H-US 1 240 VAC 21A <br />SYSTEM SIZE:- 15 X 400W = 6.000 KWDC <br /> 15 X 371.5W X 0.99 = 5.517 CEC KWAC <br />LOAD SIDE TAP <br />G <br />(N) AC DISCONNECT <br />60A FUSED,WITH 30A <br />FUSES,240 VAC <br />30A FUSES <br />C <br />(3) #4 AWG CU THWN <br />(1) #6 AWG THWN GND <br />IN 1" EMT CONDUIUT RUN <br />PER NEC TABLE 310.15(B)(7) <br />1617 W Carriage <br />Dr05/23/23
The URL can be used to link to this page
Your browser does not support the video tag.